[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663091-105":59,"doc-detail-663091-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","mx-series-technical-specifications-part-2","MX Series Technical Specifications - Part 2","","This technical document provides a comprehensive overview of the MX series mechanical models, including specifications for MXA02, MXC02, MXE02, and MXF02 units. The data encompasses physical characteristics such as ship weight, sound levels, air flow, refrigerant charge, and connection sizes. Furthermore, the document details electrical power requirements, specifying motor types, voltage configurations, full load amperes (FLA) for both fans and units, as well as Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) ratings.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/mx-series-technical-specifications-part-2/663091/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/mx-series-technical-specifications-part-2/663091.png","ImageObject",300,407,{"name":92,"@type":93},"adawds","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the ship weight for all MX series models listed?","Question",{"text":112,"@type":113},"All MX series models (MXA02, MXC02, MXE02, and MXF02) have a ship weight of 560 lbs.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the air flow compare between the MXA02 and MXF02 models?",{"text":117,"@type":113},"The MXA02 model has an air flow of 20,800 CFM, while the MXF02 model provides a higher air flow of 25,600 CFM.",{"name":119,"@type":110,"acceptedAnswer":120},"What are the motor specifications for the MXE02 model?",{"text":121,"@type":113},"The MXE02 model features a 0.5HP motor operating at 575 RPM.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663091,1793225030,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},3985747872983,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","|  | REVISION HISTORY |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  | REV | ECN |  | DATE | REVISION DESCRIPTION |  | REV BY | CHKD BY | APPR BY |  |\n|  | A | - |  | 11-07-2023 | INITIAL RELEASE |  | VG | BG | POORNA |  |\n|  |  |  |  |  |  |  |  |  |  |  |\n| \u003Cbr>\u003Cbr>\u003Cbr>MODEL SHIP\u003Cbr>WEIGHT\u003Cbr>(LBS) EST SOUND\u003Cbr>10' (dBA) AIR FLOW\u003Cbr>(CFM) CHARGE (LBS) CONNECTIONS\u003Cbr>OD IN(2) SUMMER WINTER INLET OUTLET MXA02 560 66 20800 4 17 1-3/8 1-3/8 MXC02 560 68 22830 4 17 1-3/8 1-3/8 MXE02 560 55 12600 4 17 1-3/8 1-3/8 MXF02 560 75 25600 4 17 1-3/8 1-3/8\u003Cbr>* A,C,E,F\u003Cbr>\u003Cbr>\u003Cbr>POWER\u003Cbr>VOLTAGE MOTOR TYPE A 1HP\u003Cbr>850 RPM MOTOR TYPE C-\u003Cbr>1.5HP 850 RPM MOTOR TYPE E-\u003Cbr>0.5HP 575 RPM MOTOR TYPE F-\u003Cbr>1.5HP 1140 RPM FAN\u003Cbr>FLA UNIT\u003Cbr>FLA MCA MOP FAN\u003Cbr>FLA UNIT\u003Cbr>FLA MCA MOP FAN\u003Cbr>FLA UNIT\u003Cbr>FLA MCA MOP FAN\u003Cbr>FLA UNIT\u003Cbr>FLA MCA MOP K-230/3/60 9.6 12.6 13.8 20.0 13.8 16.8 18.5 25.0 6.8 9.8 10.7 15.0 10.8 13.8 15.2 20.0\u003Cbr>U-380/3/50 4.6 6.6 7.2 15.0 5.8 7.8 8.5 15.0 2.8 4.8 5.2 15.0 4.2 6.2 6.7 15.0 |  |  |  |  |  |  |  |  |  |  |\n| M-460/3/60 4.8 6.3 6.9 15.0 6.6 8.1 8.9 15.0 3.2 4.7 5.1 15.0 5.0 6.5 7.1 15.0 P-575/3/60 3.6 4.8 5.3 15.0 5.0 6.2 6.8 15.0 3.0 4.2 4.6 15.0 5.0 6.2 6.8 15.0 L-380/3/60 N/A N/A N/A 6.0 8.0 8.8 15.0 |  |  | |  |  |  |  |  |  |  |\n|  |  |  | \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>|  |  |  |  |  |  |  |\n|  |  |  | |  |  | | |  |  |  |\n|  |  |  | |  |  | |  |  |  | \u003Cbr>|\n|  |  |  | |  |  |  |  |  |  |  |","cbCaihwcDssaPBe7","https://ap.wps.com/l/cbCaihwcDssaPBe7","pdf",365614,"English","# Model Physical Specifications\n## Electrical Power Requirements","[{\"question\":\"What is the ship weight for all MX series models listed?\",\"answer\":\"All MX series models (MXA02, MXC02, MXE02, and MXF02) have a ship weight of 560 lbs.\"},{\"question\":\"How does the air flow compare between the MXA02 and MXF02 models?\",\"answer\":\"The MXA02 model has an air flow of 20,800 CFM, while the MXF02 model provides a higher air flow of 25,600 CFM.\"},{\"question\":\"What are the motor specifications for the MXE02 model?\",\"answer\":\"The MXE02 model features a 0.5HP motor operating at 575 RPM.\"}]","MX Series Technical Specifications - Part 2 | PDF"]