[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-649334-105":59,"doc-detail-649334-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","municipal-swimming-pool-bathhouse-project-notes-equipment-product-notes","MUNICIPAL SWIMMING POOL & BATHHOUSE PROJECT - NOTES - Equipment & Product Notes","","Municipal swimming pool and bathhouse project notes specifying construction and life-safety requirements, including self-closing lockable gates, latch locations, depth markings, and lifeguard chair and equipment placement. Defines required life-saving and safety devices, pool lighting and electrical grounding with no wiring within specified distance, and detailed interconnections such as Watts DCVA and backflow prevention. Provides water recirculation, piping, overflow, drainage, pump model and instrumentation, filtration and disinfection concentration requirements, plus governing codes and equipment fixture standards for bathrooms and plumbing.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/municipal-swimming-pool-bathhouse-project-notes-equipment-product-notes/649334/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/municipal-swimming-pool-bathhouse-project-notes-equipment-product-notes/649334.png","ImageObject",300,407,{"name":92,"@type":93},"jay","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-05","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What gate and depth-marking requirements are specified for the pool and entranceway?","Question",{"text":112,"@type":113},"Entranceway and fence gates must be self-closing, positively self-latching, and lockable. Depth markings are required with specified spacing and increment limits, with break-point and contrasting striping requirements.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which life-saving equipment must be provided and how is it characterized?",{"text":117,"@type":113},"The notes require adequate life-saving equipment including a torpedo buoy and rescue tube with an indicated line length, a ring buoy with minimum diameter, a reaching pole of specified length, a first-aid kit, a spine board, and a pocket mask, with additional safety equipment references to drawings and tables.",{"name":119,"@type":110,"acceptedAnswer":120},"What are the key electrical and plumbing/system interconnection requirements?",{"text":121,"@type":113},"Wiring must conform to the National Electrical Code, pool and metal fixtures must be properly grounded, and ground fault interrupters are required at bathrooms and exterior areas. The interconnection section specifies items such as a Watts 2\" DCVA on fill/drain piping, an approved backflow preventer, and water supply compliance with the referenced code requirements.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},649334,1792799236,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144,"preview_page_count":4},3985747858866,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","# NOTES:\n\n1 FENCE &ENTRANCEWAY SHALL HAVE SELF-CLOSING AND POSITIVE SELF LATCHING LOCKABLE GATES  \n2.LATCH LOCATION TO BE PERNYSDOH(NEW YORK STATE DEPT.OF HEALTH)REQUIREMENTS  \n3.  DEPTH MARKINGS  \na.DEPTH MARKING AT WALL OR DECK,SPACED NOT MORE THAN 25 FEET AT 2'INCREMENTS OF DEPTH,MAXIMUM.MINUMUM POINT,BREAK POINT  \nh NLIMERAL HFIGHT 4 INCHES OR MORE  \nC.  COLOR CONTRASTING WITH BACKGROUND.  \nd.FLOAT LINE AT 5 FEET BREAK POINT.  \ne.4 INCH STRIPE OF CONSTRASTING COLOR AT BREAKPOINT OR 5 FOOT DEPTH &ON STEPS ORUNDERWATER LEDGES  \n4.LIFEGUARD CHAIRS ARE TO BE ADEQUATE AND LOCATION ACCEPTABLE TO NYSDOH,2 REQUIFED  \n5.LIFE SAVING EQUIPMENT PROVIDE MIN.2 UNITES OF(A)&(B)BELOW.  \na TORPEDO BUOY AND RESCUE TUBE WITHA6F0OTLINE,RINGBUOYAT LEAST 18 INCHESINDIAMETER,FITTED WITHLINCH DIAMETER LINE WITH A LENGTH OF 1.5TIMES THE MAXIMUM'VIDTH OFPOOL OR 50 FEET,WHICHEVER IS LESS  \nb.ONE REACHING POLE 15 FEET LONG  \nC.COMMERCIALLY AVAILABLE FIRST AID KIT,SEE SPECS.FOR CONTENTS  \nd.  SPINE BOARD  \ne.POCKET MASK  \nf.SEE DWG.SW-1,SAFETY EQUIPMENT TABLE FOR ADDITIONAL REQUIREMENTS.  \n6.LIGHTING AND ELECTRICAL  \na.WIRING CONFORMS TO NATIONAL ELECTRICAL CODE.b.POOL AND METAL FIXTURES PROPERLY GROUNDED.  \nNO OVEREADELECTR心AL WIRNG WTHIN20 FEET OF POOL  \nd.GROUND FAULT INTERRUPTERS PROVIDED AT BATHROOMS &EXTERIOR.  \n7.INTERCONNECTIONS  \na.WATTS 2\"DCVA PROVIDED ON FILL PIPE/DRAIN PIPE  \nb.APPROVED BACKFLOW PREVENTER INSTALLEDON PUBLIC W.S.(1'AIRGAP TO GRADE)c.WATER SUPPLY MEETS PART 5 OF CODE.8 TIUIRNOVER AND PIPING  \na.  TURNOVER RATES ACCEPTABLE AT 4 TIMES EACH DAY  \nb.SUCTION LINE VELOCITY ISLESS THAN 6FT/SEC.(3FPS)  \nc.PRESSURE LINES VELOCITY IS LESS THAN 10 FT/SEC.(6FPS  \nd.PIPING DETAILS SHOWN ON PLANS.(SCHEMATICS)e.PIPING COLOR CODED,SEE SPECS.  \n9.OVERFLOW SYSTEM  \na.  GUTTERS PROVIDED(POOL GREATER THAN 2000SQ.FT)  \nb.CAPABLE OF REMOVING 100%OF RECIRCULATION.  \nC.SURGE CAPACITY ACCEPTABLE AT 5000 GALS.  \n10.DRAINS  \na.MINIMUM TWO DRAINS PROVIDED;EACH DESIGNED TO CARRY 100%OF THE RECIRCIⅡ ATION FIOw  \nb.MAIN DRAIN(S)LOCATION IS ACCEPTABLE,20'C.C.&10'FROM WALL.  \nc.SUCTION VELOCITY THROUGH GRATE IS LESS THAN 1.5FT/SEC.  \nd.WASTE TO DISCHARGE TO SANITARY SEWER.  \n11.PUMP  \na.MAKE AND MODEL\\#,PENTAIR CH-75,CAPACITY 380@HEAD 64FT.  \nb.PUMP CURVES AND EAD LOSS CALCULATIONS ATTACHED.  \nC.  PRESSURE GAUGES PROVIDED.  \nd.FLOW METER 4\"MAGNETIC FLOW METER.  \ne.LOCATION OF FLOW METER IN STRAIGHT RUN OF PIPE  \nf.RATE OF FLOW CONTROLLERS OR WAFER VALVE TO BE PROVIDED.VALVE ADJUSTABLE TO LOCK IN  \nMULTIPLE POSITIONS.  \n12.POOL RECIRCULATION&INLET JETS  \na.TURNOVER RATES ACCEPTABLE,6 HR,MAX.300 GPM.  \nb.INLET JETS ADJUSTABLE FOR DIRECTION AND FLOW  \nC.INLET JETS FLUSH WITH POOL WALL OR FLOOR.  \n13.CARTRIDGE FILTER.FILTERS MEET STANDARDS OF ACCEPTABILITY FOR:  \na.MAKE HAYWARD,MODEL C7030,AREA 700 SQ.FT  \nb.  NSF LISTED  \nC.FILTRATION RATE 150 GPM EACH OF TWO(2)  \nd.  BACK WASH RATE NA  \ne PRESSURE GAUGES 2 EACH,0-100FT.PRESSURE-ONE BEFORE &ONE AFTER FILTER  \n14.DISINFECTION.  \na CHLORINE SYSTEM TO PROVIDED MINIMUM DISINFECTION CONCENTRATION REQUIRED,20 PPDb.PIPING TO PROVIDED SATISFACTORY CONTRACTTIME  \nMUNICIPAL SWIMMING POOL&BATHHOUSE PROJECT  \nMAIN STREET  \nDELHI,NEW YORK  \nDELAWARE COUNTY  \nGOVERNING CODES:  \nNEW YORK DEPARTMENT OF HEALTH  \nBUILDING CODE OF NEW YORK 2010  \nPLIIMBING CoDE OF NFW YORK  \nNATIONAL ELECTRICAL CODE  \nVILLAGE OF DELHI,NEW YORK WATER&SEWER REGULATION  \nNEW YORK STATE DEPT,OF ENVIRONMENTAL CONSERVATION  \nEROSION MANAGEMENT REGULATIONS  \nLOCAL GOVERNING UTILITIES REGULATION  \nEQUIPMENT&PRODUCTS NOTES  \n1.PLUMBING FIXTURES SHALL BE COMMERCIAL MODELS AMERICAN STANDARD OF EQUAL,FLUSH VALVE  \nTYPE BYP-1  \n2.BATHROOM FIXTURES&TOILET ACCESSORES FOR MENS &WOMENS ROOM SHALL EACH INCLUDE(BYP-1)  \na.ELECTRIC HAND DRYER,208 VOLT,SINGLE PHASE WALL MOUNT,POWER BY E-1.  \nb.MIRRORS,WALL MOUNT,MINIMUM 16\"×24\".  \nc.ADA APPROVED GRAB BARS,S.S.GRADE 304.  \nd.TOILET PAPER HOLDERS,TWO(2)ROLL COMMERCIAL TYPE.  \ne.  TOILET &URINAL ENCLOSURES/PARTITIONS,H","cbCaieDnaDeWCRTf","https://ap.wps.com/l/cbCaieDnaDeWCRTf","pdf",16209678,26,"English","# NOTES:\n## Gates, depth markings, and signage\n## Life-saving equipment and life-safety provisions\n## Lighting, electrical grounding, and electrical protection\n## Interconnections, turnover rates, and piping\n## Overflow system and drains\n## Pump, filtration, and disinfection\n## Governing codes and equipment/product notes","[{\"question\":\"What gate and depth-marking requirements are specified for the pool and entranceway?\",\"answer\":\"Entranceway and fence gates must be self-closing, positively self-latching, and lockable. Depth markings are required with specified spacing and increment limits, with break-point and contrasting striping requirements.\"},{\"question\":\"Which life-saving equipment must be provided and how is it characterized?\",\"answer\":\"The notes require adequate life-saving equipment including a torpedo buoy and rescue tube with an indicated line length, a ring buoy with minimum diameter, a reaching pole of specified length, a first-aid kit, a spine board, and a pocket mask, with additional safety equipment references to drawings and tables.\"},{\"question\":\"What are the key electrical and plumbing/system interconnection requirements?\",\"answer\":\"Wiring must conform to the National Electrical Code, pool and metal fixtures must be properly grounded, and ground fault interrupters are required at bathrooms and exterior areas. The interconnection section specifies items such as a Watts 2\\\" DCVA on fill/drain piping, an approved backflow preventer, and water supply compliance with the referenced code requirements.\"}]","MUNICIPAL SWIMMING POOL & BATHHOUSE PROJECT - NOTES - Equipment & Product Notes | PDF",66]