[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-652563-105":59,"doc-detail-652563-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","multiplus-safety-instructions-en-appendix","MultiPlus - Safety Instructions - EN Appendix","","Safety instructions and product description for MultiPlus (with firmware xxxx400 or higher) covering safe installation and operation. It explains intended use, electrical shock hazards with a permanent energy source, and requirements such as qualified maintenance, proper grounding, and use with correct operating conditions. Transport and storage guidance covers disconnection of mains and battery leads, original packaging for transit, and specified storage temperature range. The appendix also describes key functions including UPS-like switching, auxiliary AC output, parallel and three-phase capability, and power management features.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/multiplus-safety-instructions-en-appendix/652563/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/multiplus-safety-instructions-en-appendix/652563.png","ImageObject",300,407,{"name":92,"@type":93},"McGucket","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What key electrical safety warnings apply to the MultiPlus?","Question",{"text":112,"@type":113},"A dangerous electrical voltage can occur at input and/or output terminals even when switched off. Always switch AC power off and disconnect the battery before maintenance, and keep all servicing to qualified personnel.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the grounding requirements during installation?",{"text":117,"@type":113},"The AC input/output terminals must be provided with uninterruptible grounding for safety. If grounding protection is assumed to be damaged, the product must be taken out of operation and prevented from accidental restart.",{"name":119,"@type":110,"acceptedAnswer":120},"What additional features does MultiPlus provide beyond inverter and charging?",{"text":121,"@type":113},"It offers automatic uninterruptible switching (UPS functionality), an auxiliary AC output that disconnects during battery operation, parallel operation for increased power, three-phase capability, and power-management features such as PowerControl and PowerAssist with programmable relays.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},652563,1793029966,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},1236954412713,"https://us-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Manual  \nEN  \nAppendix  \nMultiPlus (with firmware xxxx400 or higher)  \n12 | 3000 | 120-50 | 120V ( PMP123021102 )  \n24 | 3000 | 70-50 | 120V ( PMP243021102 )  \n1. SAFETY INSTRUCTIONS  \nIn general  \nPlease read the documentation supplied with this product first, so that you are familiar with the safety signs en directions before using the product.  \nThis product is designed and tested in accordance with international standards. The equipment should be used for the designated application only.  \nWARNING: DANGER OF ELECTRICAL SHOCK  \nThe product is used in combination with a permanent energy source (battery) . Even if the equipment is switched off, a dangerous electrical voltage can occur at the input and/or output terminals. Always switch the AC power off and disconnect the battery before performing maintenance.  \nThe product contains no internal user-serviceable parts. Do not remove the front panel and do not put the product into operation unless all panels are fitted. All maintenance should be performed by qualified personnel.  \nNever use the product at sites where gas or dust explosions could occur. Refer to the specifications provided by the manufacturer of the battery to ensure that the battery is suitable for use with this product. The battery manufacturer's safety instructions should always be observed.  \nWARNING: do not lift heavy objects unassisted.  \nInstallation  \nRead the installation instructions before commencing installation activities.  \nThis product is a safety class I device (supplied with a ground terminal for safety purposes) . Its AC input and/or output terminals must be provided with uninterruptible grounding for safety purposes. An additional grounding point is located on the outside of the product. If it can be assumed that the grounding protection is damaged, the product should be taken out of operation and prevented from accidentally being put into operation again; contact qualified maintenance personnel.  \nEnsure that the connection cables are provided with fuses and circuit breakers. Never replace a protective device by a component of a different type. Refer to the manual for the correct part.  \nCheck before switching the device on whether the available voltage source conforms to the configuration settings of the product as described in the manual.  \nEnsure that the equipment is used under the correct operating conditions. Never operate it in a wet or dusty environment.  \nEnsure that there is always sufficient free space around the product for ventilation, and that ventilation openings are not blocked.  \nInstall the product in a heatproof environment. Ensure therefore that there are no chemicals, plastic parts, curtains or other textiles, etc. in the immediate vicinity of the equipment.  \nTransport and storage  \nOn storage or transport of the product, ensure that the mains supply and battery leads are disconnected.  \nNo liability can be accepted for damage in transit if the equipment is not transported in its original packaging.  \nStore the product in a dry environment; the storage temperature should range from –20°C to 60°C.  \nRefer to the battery manufacturer's manual for information on transport, storage, charging, recharging and disposal of the battery.  \nEN  \nAppendix  \n2. DESCRIPTION  \n2.1 In general  \nThe basis of the MultiPlus is an extremely powerful sine inverter, battery charger and automatic switch in a compact casing.  \nThe MultiPlus features the following additional, often unique characteristics:  \nAutomatic and uninterruptible switching  \nIn the event of a supply failure or when the generating set is switched off, the MultiPlus will switch over to inverter operation and takeover the supply of the connected devices. This is done so quickly that operation of computers and other electronic devices is not disturbed (Uninterruptible Power Supply or UPS functionality) . This makes the MultiPlus highly suitable as an emergency power system in industrial and telecommunication applications. The ","cbCaiewwz5RAXgng","https://ap.wps.com/l/cbCaiewwz5RAXgng","pdf",837451,38,"English","# 1. SAFETY INSTRUCTIONS\n## In general\n## Installation\n## Transport and storage\n# 2. DESCRIPTION\n## 2.1 In general\n## Key additional characteristics","[{\"question\":\"What key electrical safety warnings apply to the MultiPlus?\",\"answer\":\"A dangerous electrical voltage can occur at input and/or output terminals even when switched off. Always switch AC power off and disconnect the battery before maintenance, and keep all servicing to qualified personnel.\"},{\"question\":\"What are the grounding requirements during installation?\",\"answer\":\"The AC input/output terminals must be provided with uninterruptible grounding for safety. If grounding protection is assumed to be damaged, the product must be taken out of operation and prevented from accidental restart.\"},{\"question\":\"What additional features does MultiPlus provide beyond inverter and charging?\",\"answer\":\"It offers automatic uninterruptible switching (UPS functionality), an auxiliary AC output that disconnects during battery operation, parallel operation for increased power, three-phase capability, and power-management features such as PowerControl and PowerAssist with programmable relays.\"}]","MultiPlus - Safety Instructions - EN Appendix | PDF",1792881147,96]