[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-497703-105":59,"doc-detail-497703-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","multilayer-gzysz-thermal-barrier-coating-from-suspension-and-solution-precursor-plasma-spray","Multilayer GZ/YSZ Thermal Barrier Coating from Suspension and Solution Precursor Plasma Spray","","Gas turbines rely on thermal barrier coatings (TBCs) to insulate nickel-based superalloys during operation, but conventional yttria-stabilised zirconia (YSZ) limits performance. Above 1200 °C, YSZ degrades due to phase instabilities and CMAS (Calcia-Magnesia-Alumina-Silica) attack. Gadolinium zirconates (GZ) may address these issues. This work develops double- and triple-layer TBCs using axial suspension plasma spray (ASPS) and axial solution precursor plasma spray (ASPPS), improving CMAS resistance, with the triple-layer showing more limited CMAS infiltration.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/multilayer-gzysz-thermal-barrier-coating-from-suspension-and-solution-precursor-plasma-spray/497703/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/multilayer-gzysz-thermal-barrier-coating-from-suspension-and-solution-precursor-plasma-spray/497703.png","ImageObject",300,407,{"name":92,"@type":93},"Jake","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-26","2026-10-02",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",15,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"Why do YSZ thermal barrier coatings fail at operating temperatures above 1200 °C?","Question",{"text":113,"@type":114},"At temperatures above 1200 °C, YSZ is susceptible to phase instabilities and CMAS attack, which can accelerate topcoat damage and spallation.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the study’s approach improve CMAS resistance compared with single-layer systems?",{"text":118,"@type":114},"The study uses GZ/YSZ multi-layer architectures, and for the triple-layer design adds an additional dense layer via solution precursor plasma spraying to reduce columnar gaps and slow CMAS infiltration.",{"name":120,"@type":111,"acceptedAnswer":121},"Which coating design shows better performance in the CMAS test, and what is the evidence?",{"text":122,"@type":114},"The triple-layer coating shows better CMAS reactivity, evidenced by limited CMAS infiltration observed on the surface.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},497703,1791077166,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":24,"preview_urls":147},962084928904,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Multilayer GZ/YSZ Thermal Barrier Coating from Suspension and Solution Precursor Plasma Spray  \nK. Leng*, A. Rincon Romero, T. Hussain*  \nCoatings and Surface Engineering, Faculty of Engineering, University of Nottingham, NG7 2RD +44 115 951 3795, [Tanvir.Hussain@nottingham.ac.uk](Tanvir.Hussain@nottingham.ac.uk)  \nAbstract  \nGas turbines rely on thermal barrier coating (TBC) to thermally insulate the nickel-based superalloys underneath during operation; however, current TBCs, yttria stabilised zirconia (YSZ), limit the operating temperature and hence efficiency. At an operating temperature above 1200 °C, YSZ is susceptible to failure due to phase instabilities and CMAS (Calcia-Magnesia-Alumina-Silica) attack. Gadolinium zirconates (GZ) could overcome the drawback of YSZ, complementing each other with the multi-layer approach. This study introduces a novel approach utilising axial suspension plasma spray (ASPS) and axial solution precursor plasma spray (ASPPS) to produce a double-layer and a triple-layer TBCs with improved CMAS resistance. The former comprised suspension plasma sprayed GZ and YSZ layers while the latter had an additional dense layer deposited through a solution precursor to minimise the columnar gaps that preexisted in the SPS GZ layer, thus resisting CMAS infiltration. Both coatings performed similarly in furnace cycling test (FCT) and burner rig testing (BRT) . In the CMAS test, triple-layer coating showed better CMAS reactivity, as evidenced by the limited CMAS  \ninfiltration observed on the surface.  \n1. Introduction  \nThe implementation of a net-zero economy has encouraged the development of more efficient gas turbine engines. Based on Carnot cycles, the efficiency of a combustion engine is directly related to the turbine entry temperature (TET) [1] . Thus, the higher the TET, the higher the efficiency of a gas turbine engine [2] . With the higher operating temperature, the bare nickel-based superalloy components may have reached the melting temperature, resulting in the risk of creep failure over an extended period. The implementation of thermal barrier coatings (TBCs) on these components helped to improve their lifetime. TBCs are a thermal insulation layer that protects the underlying  \nmetallic substrates from the harsh environment by reducing the surface temperature of the components in the range of 100 – 300 ºC [3] .  \nIn general, a TBC system is comprised of a substrate, a bond coat and a ceramic topcoat. The bond coat, platinum/nickel aluminide or MCrAlY (M = Co or Ni), is a metallic layer that aims to minimise the thermal strain between the substrate and the topcoat and improving oxidation resistance of the underlying substrate, thereby enhancing the durability of the coating [4] . The ceramic topcoat is mainly zirconia-based ceramics, yttria stabilised zirconia (YSZ), which have been developed and employed since the 1970s [5]; however, YSZ encounters phase transformations beyond 1200 ºC, subsequently inducing a high-level stress into the topcoat [6] . The induced stress will speed up the spallation of the topcoat, and reveal the underlying substrate, resulting in a catastrophic failure of the safety-critical component. In addition to that, the YSZ is prone to CMAS (Calcia-Magnesia-Alumina-Silica) attack at 1200 ºC or higher, leading to early spallation of the topcoat. The drawback of the current TBC (i.e., YSZ) initiated the search for the next-generation TBC materials, thereby shifting the attention towards rare-earth (RE) zirconates, either the lanthanum zirconate (LZ) or the gadolinium zirconate (GZ) . The RE zirconates gained attention to overcome the drawbacks of YSZ because of their lower thermal conductivity, the higher phase stability at elevated temperatures and the ability to react with CMAS to form a protective apatite phase; however, RE zirconateshave a lower fracture toughness than YSZ, resulting in a poor thermal cycling life for a single-layer system. Hence, a multi-layer approach ","cbCairrkBZTPD6cL","https://ap.wps.com/l/cbCairrkBZTPD6cL","pdf",12685197,42,"English","# Abstract\n# 1. Introduction","[{\"question\":\"Why do YSZ thermal barrier coatings fail at operating temperatures above 1200 °C?\",\"answer\":\"At temperatures above 1200 °C, YSZ is susceptible to phase instabilities and CMAS attack, which can accelerate topcoat damage and spallation.\"},{\"question\":\"How does the study’s approach improve CMAS resistance compared with single-layer systems?\",\"answer\":\"The study uses GZ/YSZ multi-layer architectures, and for the triple-layer design adds an additional dense layer via solution precursor plasma spraying to reduce columnar gaps and slow CMAS infiltration.\"},{\"question\":\"Which coating design shows better performance in the CMAS test, and what is the evidence?\",\"answer\":\"The triple-layer coating shows better CMAS reactivity, evidenced by limited CMAS infiltration observed on the surface.\"}]","Multilayer GZ/YSZ Thermal Barrier Coating from Suspension and Solution Precursor Plasma Spray | PDF",1790964755,106,[148,152,156,160,164],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/314503abf523359d12740fc15651fc3a.webp",983,1390,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ec97bfbf52f32410838b25761533dfe9.webp",982,1389,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/5def2f761f33227456e5a82521a2606e.webp",981,1387,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/dbbbd358c01226c183e2fcc0f773464b.webp",980,1386,{"page_no":24,"url":165,"width":166,"height":167},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/67398588c1543d3c4a4b64dd1dcb1919.webp",979,1385]