[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-377342-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-377342-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","multifractal-analysis-of-cellular-atrftir-spectrum-as-a-method-for-identifying-and-quantifying-cancer-cell-metastatic-levels","Multifractal analysis of cellular ATR‑FTIR spectrum as a method for identifying and quantifying cancer cell metastatic levels","","The study evaluates multifractal transformation of Attenuated Total Reflection-Fourier Transform Infrared (ATR-FTIR) spectra to generate a unique numerical value reflecting each cancer cell line’s metastatic potential. Results across murine and human cancer cells show correlation between metastatic capacity within the same lineage and higher multifractal values. The multifractal spectrum value is independent of assay cell concentration, distinct across tested lineages, and lower for healthy cells than cancer cells. The method can detect cancer progression by sensitivity to proportional shifts between healthy and cancerous cells, enabling observer-bias-free quantification and improved diagnostic and prognostic potential.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/multifractal-analysis-of-cellular-atrftir-spectrum-as-a-method-for-identifying-and-quantifying-cancer-cell-metastatic-levels/377342/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/multifractal-analysis-of-cellular-atrftir-spectrum-as-a-method-for-identifying-and-quantifying-cancer-cell-metastatic-levels/377342.png","ImageObject",300,407,{"name":42,"@type":43},"Jasmine","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-23","2026-09-24",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",12,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"How does the method estimate cancer metastatic potential from cells?","Question",{"text":63,"@type":64},"It converts ATR‑FTIR spectra using multifractal transformation to produce a unique numerical value for each cell line’s metastatic potential.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Is the multifractal spectrum value affected by cell concentration in the assay?",{"text":68,"@type":64},"No. The multifractal spectrum value was reported as independent of the cell concentration used in the assay.",{"name":70,"@type":61,"acceptedAnswer":71},"How does the technique distinguish healthy cells from cancer cells?",{"text":72,"@type":64},"Healthy cells exhibit a smaller multifractal spectrum value than cancer cells, enabling separation between healthy and cancerous states.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},377342,1790668639,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":124,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},2336478487870,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nMultifractal analysis of cellular ATR‑FTIR spectrum as a method for identifying and quantifying cancer cell metastatic levels  \nAyan Barbora1,5, Sirish Karri2,5, Michael A. Firer2,3,4 & Refael Minnes1*  \nCancer is a leading cause of mortality today. Sooner a cancer is detected, the more effective is the treatment. Histopathological diagnosis continues to be the gold standard worldwide for cancer diagnosis, but the methods used are invasive, time‑consuming, insensitive, and still rely to some degree on the subjective judgment of pathologists. Recent research demonstrated that Attenuated Total Reflection‑Fourier Transform Infrared (ATR‑FTIR) spectroscopy can be used to determine the metastatic potential of cancer cells by evaluating their membrane hydration. In the current study, we demonstrate that the conversion of ATR‑FTIR spectra using multifractal transformation generates a unique number for each cell line’s metastatic potential. Applying this technique to murine and human cancer cells revealed a correlation between the metastatic capacity of cancer cells within the same lineage and higher multifractal value. The multifractal spectrum value was found to be independent of the cell concentration used in the assay and unique to the tested lineage. Healthy cells exhibited a smaller multifractal spectrum value than cancer cells. Further, the technique demonstrated the ability to detect cancer progression by being sensitive to the proportional change between healthy and cancerous cells in the sample. This enables precise determination of cancer metastasis and disease progression independent of cell concentration by comparing the measured spectroscopy derived multifractal spectrum value. This quick and simple technique devoid of observer bias can transform cancer diagnosis to a great extent improving public health prognosis worldwide.  \nCancer continues to be a major contributor to deaths worldwide1, 2. Timely detection of the disease and identification of at-risk individuals is crucial to success of effective treatments, which can greatly increase the survival rate of patients. The current technologies for screening and diagnosis involving imaging techniques are generally insensitive and detect disease only when tumor mass is already generated and visible3, Another concerning aspect of current cancer diagnosis is the variability of disease classification amongst pathologists. For example, a study in 2017 on inter-observer and intra-observer variability among pathologists using visual inspection of tissue sections observed that 17% of melanocytic lesions diagnosed in the US are incorrect4. Although diagnosticians utilize specific features from biopsy materials on microscopic slides, radiographs, and patients’ physical examination, the diagnoses incorporate individual perspectives in the processing, grading and categorization of medical information4, 5. As such, the reliability and predictive values of these diagnostic criteria have never been established with rigorous standards until now due to high levels of diagnostic discordance across pathologists in interpreting cancerous lesions6–9, demonstrating the serious state of both overdiagnosis and underdiagnosis5, 10 in current medical practice. Records show that pathologists’ interpretations ofthe same case on two occasions lacked reproducibility4, making this low level of diagnostic precision a serious clinical concern. Also, computer aided detection (CAD) tools that are widely used in clinical practice to aid the interpretation and diagnosis have been found to cause potential harms, such as higher recall and biopsy rates for screening mammography11. Thus, reliable and objective techniques are needed to validate and support pathologists’ visual assessments of cancerous lesions, which can overcome the subjective bias in observer-derived opinions about diagnostic certainty, perceived risk for disease pro","cbCaibS1qlFRVr6F","https://ap.wps.com/l/cbCaibS1qlFRVr6F","pdf",2392724,"English","# Introduction\n## Limitations of current cancer diagnosis\n## Need for objective, concentration-independent techniques\n# Method Background\n## ATR-FTIR spectroscopy and membrane hydration\n## Spectral zones and characteristic parameters\n# Multifractal Analysis (work overview)","[{\"question\":\"How does the method estimate cancer metastatic potential from cells?\",\"answer\":\"It converts ATR‑FTIR spectra using multifractal transformation to produce a unique numerical value for each cell line’s metastatic potential.\"},{\"question\":\"Is the multifractal spectrum value affected by cell concentration in the assay?\",\"answer\":\"No. The multifractal spectrum value was reported as independent of the cell concentration used in the assay.\"},{\"question\":\"How does the technique distinguish healthy cells from cancer cells?\",\"answer\":\"Healthy cells exhibit a smaller multifractal spectrum value than cancer cells, enabling separation between healthy and cancerous states.\"}]","Multifractal analysis of cellular ATR‑FTIR spectrum as a method for identifying and quantifying cancer cell metastatic levels | PDF",1790224414,25,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ec7c344391b77414ea3a45287d962073.webp",983,1291,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/b42409fe769da0aee792adc27644c36a.webp",982,1290,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/464cb5f5d1b2b2b3fed776319398f510.webp",981,1289,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/bbe8682c3b57dde3248613ef9ad492b7.webp",980,1287]