[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-489176-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-489176-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","multi-element-germanium-detectors-for-synchrotron-applications","Multi-element Germanium Detectors for Synchrotron Applications","","A study presents monolithic multi-element germanium detector systems built from Forschungzentrum Julich sensor arrays and Brookhaven-developed ASIC readout electronics. Detector element counts span 64 to 384 and are deployed at NSLS-II and APS for monochromatic and energy-dispersive diffraction experiments. Compact, high-power FPGA-based readout architecture embeds multi-core processors in large gate arrays. Technical system details and early experimental results are discussed alongside detector and electronics performance considerations relevant to synchrotron diffraction.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/multi-element-germanium-detectors-for-synchrotron-applications/489176/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/multi-element-germanium-detectors-for-synchrotron-applications/489176.png","ImageObject",300,407,{"name":42,"@type":43},"sagouaw","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-16","2026-10-01",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",7,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What detector technology is developed for synchrotron applications?","Question",{"text":63,"@type":64},"The work develops monolithic multi-element germanium detectors using sensor arrays from Forschungzentrum Julich and ASIC-based readout electronics from Brookhaven.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How many detector elements do the prototypes include?",{"text":68,"@type":64},"Devices were made with element counts ranging from 64 to 384, supporting multi-element diffraction measurements.",{"name":70,"@type":61,"acceptedAnswer":71},"Where are these detectors used and for what experiment types?",{"text":72,"@type":64},"They are used at NSLS-II and APS for both monochromatic and energy-dispersive diffraction experiments.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},489176,1791102754,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":123,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144,"preview_page_count":33,"preview_urls":145},3985747862151,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Multi-element Germanium Detectors for Synchrotron Applications  \nAbdul K. Rumaiz(a), Anthony J. Kuczewski(a), Joseph Mead(a), Emerson Vernon(a) , Donald Pinelli(a), Eric Dooryhee(a), Sanjit Ghose(a), Thomas Caswell(a),D. Peter Siddons(a) Antonino Miceli(b), Jonathan Baldwin(b),Jonathan Almer(b), John Okasinski(b), Orlando Quaranta(b), Russell Woods(b) ,Thomas Krings(c) and Stuart Stock(d)  \na Brookhaven National Laboratory Upton, New York 11973, USA b Argonne National Laboratory Argonne, Illinois 60439, USAcForschungzentrum Julich GmbH,  \n52425 Julich, Germany dNorthwestern University,  \nEvanston, Illinois 60208, USA E-mail: [rumaiz@bnl.gov](rumaiz@bnl.gov)  \nABSTRACT: We have developed a series of monolithic multi-element germanium detectors, based on sensor arrays produced by the Forschungzentrum Julich, and on Application-specific integrated circuits (ASICs) developed at Brookhaven. Devices have been made with element counts ranging from 64 to 384. These detectors are being used at NSLS-II and APS for a range of diffraction experiments, both monochromatic and energy-dispersive. Compact and powerful readout systems have been developed, based on the new generation of FPGA system-on-chip devices, which provide closely coupled multi-core processors embedded in large gate arrays. We will discuss the technical details of the systems, and present some of the results from them.  \nKEYWORDS: Detectors; Multielement; Germanium; Synchrotron.  \nContents  \n1.Ge detectors for high-energy X-rays 1  \n2. Sensor technology 2  \n3. Readout electronics 2  \n3.1 The MARS readout ASIC 2  \n3.2 The Ge Readout Module (GeRM) 3  \n4. EDX 5  \n4.2 192-strip detector 6  \n5. Monochromatic diffraction 7  \n5.1 384-strip detector 7  \n5.2 Examples 7  \n6. Charge sharing and position interpolation 7  \n7. Summary 8  \n1. Ge detectors for high-energy X-rays  \nGermanium has been the material of choice for the detection of high-energy X- and Gamma-rays for many years due to its availability in high quality and in large volumes. Consequently, efficient detectors can be built. The high purity permits full depletion at reasonable bias voltages, and its low defect density provides excellent charge collection efficiency. Its main drawback is the need to cool the material to cryogenic temperatures to eliminate thermally-generated carriers. However, modern closed-cycle cryostats have greatly reduced that burden. Figure 1 compares the absorption properties of germanium and silicon as a function of photon energy. Typical silicon detectors are formed from high-resistivity silicon wafers of thickness 0.5 mm. For this thickness, full depletion can be achieved with bias voltages of 100V or so. As can be seen, this thickness provides reasonable efficiency (> 20%) up to energies of 25 keV. Increasing the silicon thickness to 3 mm improves the performance significantly; however such a detector would need to be biased to several kilovolts for full depletion, and would need also to be cryo-cooled to reduce its leakage current sufficiently. The advantage offered by germanium is obvious, with a 3 mm detector holding its efficiency above 20% beyond 200 keV. Our detectors described here are all 3 mm thick, and were operated at bias voltages below 300V for full depletion.  \n2. Sensor technology  \nThe sensors used in this work were all produced at FZ Julich[1], and were based on a technology which relied on the use of trenches to provide pixel-pixel electrical isolation. This technique is simple and reliable and produces high-quality devices with excellent yield. Figure 2  \nshows an optical micrograph of one of these sensors. This particular one had strips with a pitch of 0.125 mm, with 30 µm wide trenches separating them. The sensor is mounted to a commercial cryo-cooler and the operating temperature of the sensor was around 100 K.  \n3. Readout electronics  \nWe initially tested these sensors using a simplified readout system based on the HERMES application specific integrated circuit (ASIC) ","cbCaihgY1e1Ds61r","https://ap.wps.com/l/cbCaihgY1e1Ds61r","pdf",765284,"English","# 1. Ge detectors for high-energy X-rays\n## 2. Sensor technology\n## 3. Readout electronics\n## 4. EDX\n## 5. Monochromatic diffraction\n## 6. Charge sharing and position interpolation\n## 7. Summary","[{\"question\":\"What detector technology is developed for synchrotron applications?\",\"answer\":\"The work develops monolithic multi-element germanium detectors using sensor arrays from Forschungzentrum Julich and ASIC-based readout electronics from Brookhaven.\"},{\"question\":\"How many detector elements do the prototypes include?\",\"answer\":\"Devices were made with element counts ranging from 64 to 384, supporting multi-element diffraction measurements.\"},{\"question\":\"Where are these detectors used and for what experiment types?\",\"answer\":\"They are used at NSLS-II and APS for both monochromatic and energy-dispersive diffraction experiments.\"}]","Multi-element Germanium Detectors for Synchrotron Applications | PDF",1790821043,25,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/172ad0297e53cc899300d29052eb0a86.webp",983,1390,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c19869336fd3a7bfc2c3088227fd5cf0.webp",982,1388,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/9249c87464fbe4401335ad34a3a3c310.webp",981,1387,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/0ab54628b29b71bd1e2d142e51cf016a.webp",980,1385]