[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-672941-105":3,"detail-sidebar-cat-0-en-105":79,"doc-detail-672941-en":129},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":72,"head_meta":74,"extra_data":76,"updated_unix":78},105,"en","mplab-harmony-integrated-software-framework-v1-11-release-notes-april-2017","MPLAB Harmony Integrated Software Framework v1 - 11 - Release Notes - April 2017","","Release notes for MPLAB Harmony Integrated Software Framework version v1.11, released in April 2017. Includes software requirements, guidance for updating, and a structured overview of what is new plus retained known issues. Highlights limitations such as no tested C++ support, recommended linker optimization settings, and specific middleware/library issues across bootloader, crypto, file system, graphics, TCP/IP, USB device/host components.",{"@graph":14,"@context":71},[15,34,54],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/mplab-harmony-integrated-software-framework-v1-11-release-notes-april-2017/672941/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":48,"encodingFormat":47,"isAccessibleForFree":49,"interactionStatistic":50},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/mplab-harmony-integrated-software-framework-v1-11-release-notes-april-2017/672941.png","ImageObject",300,407,{"name":42,"@type":43},"xXChrisXx","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-02",true,{"@type":51,"interactionType":52,"userInteractionCount":22},"InteractionCounter",{"@type":53},"ViewAction",{"@type":55,"mainEntity":56},"FAQPage",[57,63,67],{"name":58,"@type":59,"acceptedAnswer":60},"What version of MPLAB Harmony do these release notes cover?","Question",{"text":61,"@type":62},"They cover MPLAB Harmony Integrated Software Framework version v1.11.","Answer",{"name":64,"@type":59,"acceptedAnswer":65},"When was MPLAB Harmony v1.11 released?",{"text":66,"@type":62},"The release date is April 2017.",{"name":68,"@type":59,"acceptedAnswer":69},"What key software requirements must be installed before using MPLAB Harmony?",{"text":70,"@type":62},"Install MPLAB X IDE 3.60, MPLAB XC32 C/C++ Compiler 1.43, and MPLAB Harmony Configurator 1.11.xx.","https://schema.org",{"og:url":32,"og:type":73,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":75,"canonical":32},"index,follow",{"doc_id":77,"site_id":7},672941,1793615639,{"code":4,"msg":80,"data":81},"success",[82,86,90,94,99,103,108,113,118,121,125],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":83,"show_sort_weight":84,"slug":85},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":87,"show_sort_weight":88,"slug":89},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},"Exam",70,"exam",{"id":95,"doc_module":4,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},5,"Comic",60,"comic",{"id":100,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":101,"slug":102},6,50,"technology",{"id":104,"doc_module":4,"doc_module_name":25,"category_name":105,"show_sort_weight":106,"slug":107},7,"Healthcare",40,"healthcare",{"id":109,"doc_module":4,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},8,"Research & Report",30,"research-report",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},9,"Religion & Spirituality",20,"religion-spirituality",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":119,"show_sort_weight":116,"slug":120},"World Cup","world-cup",{"id":122,"doc_module":4,"doc_module_name":25,"category_name":123,"show_sort_weight":122,"slug":124},10,"Lifestyle","lifestyle",{"id":126,"doc_module":4,"doc_module_name":25,"category_name":127,"show_sort_weight":95,"slug":128},19,"General","general",{"code":4,"msg":80,"data":130},{"doc_id":77,"user_id":131,"nickname":42,"user_avatar":132,"doc_module":4,"category_id":100,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":138,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":78,"read_time":143},8796112263567,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","MPLAB® Harmony HelpUnderstanding MPLAB Harmony  \nMPLAB Harmony Integrated Software Framework v1 .11  \n© 2013-2017 Microchip Technology Inc. All rights reserved.  \nRelease Notes   \nThis topic provides the release notes for this version of MPLAB Harmony.  \nDescription  \nMPLAB Harmony Version: v1 .11 Release Date: April 2017  \nSoftware Requirements  \nBefore using MPLAB Harmony, ensure that the following are installed:  \n• MPLAB X IDE 3.60  \n• MPLAB XC32 C/C++ Compiler 1.43  \n• MPLAB Harmony Configurator 1.11.xx  \nUpdating to This Release of MPLAB Harmony  \nUpdating to this release of MPLAB Harmony is relatively simple. For detailed instructions, please refer to Porting and Updating to MPLAB Harmony.  \nWhat is New and Known Issues  \nThe following tables list the features that have been changed or added and any known issues that have been identified since the last release of MPLAB Harmony. Any known issues that have yet to be resolved were retained from the previous release.  \nMPLAB Harmony:  \n\n| Feature | Additions and Updates | Known Issues |\n| --- | --- | --- |\n| General |  | MPLAB Harmony has not been tested with C++; therefore, support for this programming language is not supported.\u003Cbr>The \" -O1\" optimization level is recommended when building any projects that include the MPLAB Harmony prebuilt binary ( .a file) peripheral library. This is necessary so that the linker will remove code from unused sections (for peripheral library features that are not used) . Alternately, you may select \"Remove Unused Sections\" in the General options for the xc32-ld (linker) properties dialog box.\u003Cbr>The MPLAB Harmony uninstaller will delete all files installed by the installer, even if they were modified by the user. However, the uninstaller will not delete new files added by the user to the MPLAB Harmony installation folder.\u003Cbr>The MPLAB Harmony Display Manager plug-in provides complete configuration and simulation support to the LCC generated driver, and also provides basic support for all other graphics controller drivers. Full configuration and simulation support for the other graphics controller drivers will be added in a future release of MPLAB Harmony. |\n\nMiddleware and Libraries:  \n\n| Feature | Additions and Updates | Known Issues |\n| --- | --- | --- |\n| Bootloader Library |  | The UDP bootloader does not compile for PIC32MZ devices when microMIPS is selected. |\n| Crypto Library | N/A | Migrating projects that use the hardware Crypto library, and have multiple configurations, may run into a compile issue after regenerating code. MPLAB X IDE will show that thepic32mz-crypt .h and pic32mz-hash .c files are excluded from the configuration, even though it tried to add them. The compiler will generate errors, saying that certain Crypto functions cannot be referenced. To work around this issue, remove both files (pic32mz-crypt .h and pic32mz-hash.c) from the project and use the MPLAB Harmony Configurator (MHC) to regenerate all configurations that use these files. |\n\n\n| Decoder Libraries |  | Due to memory requirements and the amount of available SRAM, some decoders cannot operate concurrently with other decoders. However, each decoder will operate individually in the universal_audio_decoders demonstration. |\n| --- | --- | --- |\n| File System | Found and fixed potential null pointer exception in the unmount function. |  |\n| Graphics Libraries |  | JPEG decoding does not support progressive scanned images. Some transparency-incorporated animated GIF images may demonstrate tearing.\u003Cbr>The generated LCCG driver supports display resolution up to WVGA or equivalent. |\n| TCP/IP Stack |  | SMTPC:\u003Cbr>• API to abort a message, which is useful when retries are needed is currently not available\u003Cbr>• Multiple DNS addresses to provide a more reliable mail transmission is currently not available\u003Cbr>• Support for the optional mail header fields is currently not available |\n| USB Device Library | N/A | The USB Device Stack has been tested in limited capaci","cbCaiaYz2gGOjbI1","https://ap.wps.com/l/cbCaiaYz2gGOjbI1","pdf",729891,59,"English","# Release Notes\n## MPLAB Harmony Version and Release Date\n## Software Requirements\n## Updating to This Release\n## What Is New and Known Issues\n## Middleware and Libraries","[{\"question\":\"What version of MPLAB Harmony do these release notes cover?\",\"answer\":\"They cover MPLAB Harmony Integrated Software Framework version v1.11.\"},{\"question\":\"When was MPLAB Harmony v1.11 released?\",\"answer\":\"The release date is April 2017.\"},{\"question\":\"What key software requirements must be installed before using MPLAB Harmony?\",\"answer\":\"Install MPLAB X IDE 3.60, MPLAB XC32 C/C++ Compiler 1.43, and MPLAB Harmony Configurator 1.11.xx.\"}]","MPLAB Harmony Integrated Software Framework v1 - 11 - Release Notes - April 2017 | PDF",149]