[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-374473-105":59,"doc-detail-374473-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","motor-free-soft-robots-for-cancer-detection-surgery-and-in-situ-bioprinting","Motor-Free Soft Robots for Cancer Detection, Surgery, and In Situ Bioprinting","","Recent advances in teleoperated surgical robotic systems improve minimally invasive surgery outcomes, yet increasing procedure complexity demands more capable surgical instruments. This research introduces a portable, motor-free soft robotic platform with soft robotic arms based on a soft fibrous syringe architecture to avoid complex control while enabling precise motion (mean errors \u003C300 µm) and reduced tremor. Two arm designs, with and without a central lumen, integrate microelectrodes for electrical impedance-based cancer detection, radio-frequency ablation, biomaterial injection, and in situ 3D printing for internal wound healing.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/motor-free-soft-robots-for-cancer-detection-surgery-and-in-situ-bioprinting/374473/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/motor-free-soft-robots-for-cancer-detection-surgery-and-in-situ-bioprinting/374473.png","ImageObject",300,407,{"name":92,"@type":93},"Sophia Brooks","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why are motor-free soft robotic arms proposed for minimally invasive surgery?","Question",{"text":112,"@type":113},"The system targets key TSRS challenges such as rigidity, suboptimal actuation, large size, and complex control, using a soft fibrous syringe architecture that removes the need for complex control while enabling precise motion.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the platform support cancer detection?",{"text":117,"@type":113},"Microelectrodes integrated into the soft robotic arms enable electrical impedance measurements, supporting in situ detection of tumor tissue in suspicious regions.",{"name":119,"@type":110,"acceptedAnswer":120},"What additional therapeutic capabilities are demonstrated beyond detection?",{"text":121,"@type":113},"The system supports radio-frequency ablation for surgical treatments, as well as biomaterial injections and in situ 3D printing for internal wound healing.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},374473,1792251990,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962084925636,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","RESEARCH ARTICLE  \n[www.advhealthmat.de](www.advhealthmat.de)  \nMotor-Free Soft Robots for Cancer Detection, Surgery, and In Situ Bioprinting  \nChi Cong Nguyen, James Davies, Aditya Ashok, Trung Thien Hoang, Anahid Ehteda, Tran Bach Dang, Emanuele Nicotra, Hien A. Tran, Bibhu Sharma, Kefan Zhu, Phuoc Thien Phan, Adrienne Ji, Jingjing Wan, Jelena Rnjak-Kovacina, Orazio Vittorio, Hoang-Phuong Phan, Nigel Hamilton Lovell, and Thanh Nho Do*  \nRecent advancements in teleoperated surgical robotic systems (TSRSs) for minimally invasive surgery (MIS) have signiﬁcantly improved diagnostic and surgical outcomes. However, as the complexity of MIS procedures continues to grow, there is an increasing need to enhance surgical tools by integrating advanced functionalities into these instruments for superior medical results. Despite recent advancements, TSRSs face signiﬁcant challenges, including rigidity, suboptimal actuation methods, large sizes, and complex control mechanisms. This paper presents a portable, motor-free soft robotic system equipped with soft robotic arms (SRAs) that provides an innovative solution for performing MIS within complex human organs. Unlike conventional approaches, these SRAs leverage a soft ﬁbrous syringe architecture for operation, eliminating the need for complex control systems. This design achieves precise motion control with mean errors \u003C300 µm, eﬀectively minimizing physical tremors. Two SRAs—one with and one without a central lumen—are developed. By integrating microelectrodes into the SRAs, the system demonstrates capabilities to support cancer detection via electrical impedance measurements and to perform radio-frequency ablation for surgical treatments. Additionally, the system supports biomaterial injectionsand in situ 3D printing for internal wound healing. This simple, cost-eﬀective platform represents a promising new direction for developing TSRSs in MIS.  \n1. Introduction  \nLung, gastrointestinal (GI), and brain (nervous system) cancers, along with other cancers in tubular organs represent the top leading causes of cancer deaths worldwide. Presently, signiﬁcant challenges emerge in early detection/diagnosis and treatment regimes. [1] Traditional diagnostic methods, including biopsy, imaging (e.g., X-ray, CT scan, and MRI), or cytology often fail to detect small tumors accurately.[2] For instance, imaging methods can yield false-positive outcomes, complicating the diagnosis and subsequent treatment plans. In situ (direct) detection using onboard electronics such as electrical impedance measurements via minimally invasive delivery techniques has emerged as a transformative solution. This approach leverages the electrical impedance spectroscopy (EIS) measured from the integrated metal electrodes at the tip of miniaturized surgical instruments to detect the tumor tissue in suspicious lesions. [3,4] By integrating EIS into ﬂexible surgical instruments such as endoscopes, bronchoscopes, and catheters, a more precise  \nC. C. Nguyen, J. Davies, T. T. Hoang, E. Nicotra, H. A. Tran, B. Sharma, K. Zhu, P. T. Phan, A. Ji, J. Wan, J. Rnjak-Kovacina, N. H. Lovell, T. N. Do  \nGraduate School of Biomedical Engineering Faculty of Engineering  \nand Tyree Institute of Health Engineering (IHealthE) UNSW Sydney  \nKensington Campus, Sydney, NSW 2052, Australia E-mail: [tn.do@unsw.edu.au](tn.do@unsw.edu.au)  \nThe ORCID identiﬁcation number(s) for the author(s) of this article  \ncan be found under [https://doi.org/10.1002/adhm.202404623](https://doi.org/10.1002/adhm.202404623)[ ](https://doi.org/10.1002/adhm.202404623)© 2025 The Author(s). Advanced Healthcare Materials published by Wiley-VCH GmbH. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modiﬁcations or adaptations are made.  \nA. Ashok, T. B. Dang, H.-P. Phan  \nSchool of ","cbCaif7BDZjbflZE","https://ap.wps.com/l/cbCaif7BDZjbflZE","pdf",14381111,15,"English","# Introduction\n## Background: MIS and current limitations\n## In situ detection via electrical impedance measurements\n## Need for flexible instruments and tremor mitigation\n## Regenerative approaches: biomaterial injection and 3D bioprinting","[{\"question\":\"Why are motor-free soft robotic arms proposed for minimally invasive surgery?\",\"answer\":\"The system targets key TSRS challenges such as rigidity, suboptimal actuation, large size, and complex control, using a soft fibrous syringe architecture that removes the need for complex control while enabling precise motion.\"},{\"question\":\"How does the platform support cancer detection?\",\"answer\":\"Microelectrodes integrated into the soft robotic arms enable electrical impedance measurements, supporting in situ detection of tumor tissue in suspicious regions.\"},{\"question\":\"What additional therapeutic capabilities are demonstrated beyond detection?\",\"answer\":\"The system supports radio-frequency ablation for surgical treatments, as well as biomaterial injections and in situ 3D printing for internal wound healing.\"}]","Motor-Free Soft Robots for Cancer Detection, Surgery, and In Situ Bioprinting | PDF",1790201733,38,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/70ee24515ef8458234246db2e4013b64.webp",983,1291,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/be742d8242b88b5e56935228c2190336.webp",982,1290,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/a14c6d8c67232a87b196636d00add8b9.webp",981,1289,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/619b4f4bcca7e27da95edd7e3a132c0b.webp",980,1287]