[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-155067-105":59,"doc-detail-155067-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","monroe-282is-and-282a-1-electrostatic-fieldmeters-data-sheet","Monroe 282IS and 282A-1 Electrostatic Fieldmeters - Data Sheet","","Full-featured handheld electrostatic fieldmeters for static surveys in electronic manufacturing and industrial operations, designed for consistently accurate non-contact measurements. The Monroe 282-IS Digital Stat-ArcTM 2 and Monroe 282A-1 Digital Stat-ArcTM 3 measure voltages up to 20 kV using a rangefinder LED beam and provide 100 V resolution with drift-free accuracy in ionized environments. Includes recorder output, optional charge plate system testing, straightforward operation steps, and technical specifications covering performance, mechanical, electrical, and environmental ratings.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/monroe-282is-and-282a-1-electrostatic-fieldmeters-data-sheet/155067/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/monroe-282is-and-282a-1-electrostatic-fieldmeters-data-sheet/155067.png","ImageObject",300,407,{"name":92,"@type":93},"Liam","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-06","2026-08-28",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"How do the Monroe 282IS and 282A-1 meters perform non-contact measurements?","Question",{"text":112,"@type":113},"They use a rangefinder LED beam that indicates when the instrument is at the correct distance from the target, enabling consistent readings of field strength and charged surface voltage up to 20 kV.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What accuracy and response time can be expected?",{"text":117,"@type":113},"Accuracy is listed as ±5% of reading with zero offset and ±LSD, and response time is typically 80 to 100 msec for 10 to 90% measurement response.",{"name":119,"@type":110,"acceptedAnswer":120},"What maintenance is required to keep readings accurate and drift-free?",{"text":121,"@type":113},"Replace the battery annually or when BAT appears, and keep the sensor plate and the area around the aperture absolutely clean. Never touch the aperture with anything, even a cotton swab.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},155067,1787904766,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":19,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":52},8796095461564,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","MONROE 282IS AND 282A-1  \nFull-featured, hand-held fieldmeters for performing static surveys and evaluate charge accumulation in electronic manufacturing and in industrial operations.  \nThe Monroe 282-IS Digital Stat-ArcTM 2 and Monroe 282A-1 Digital Stat-ArcTM 3 are pocket-sized, non-contacting static meters for consistently accurate readings. Simply hold the instrument so the rangefinder LED beams from a non-pulsing circle indicating you're at exactly the right distance from the target for readings up to 20 kV.  \nPRODUCT HIGHLIGHTS  \nHIGHLIGHTS  \nNormal Range  \n0 to ±19.99 kV @ 1 in  \nAccuracy  \n􀂄 Easy-to-read digital display of field strength provides quantitative data with 100V resolution  \n􀂄 LED pulsed beam range finder identifies calibrated distance from the surface  \n􀂄 Chopper-stabilized measurement technique works in the presence of ionization  \n􀂄 Recorder output to pass measurements to auxiliary instruments to display or record the data  \n􀂄 Drift-free accuracy even in ionized environments  \n􀂄 Optional Charge Plate System for testing ionization systems  \n􀂄 Monroe 282IS is UL approved for use in hazardous environments  \nTYPICAL APPLICATIONS  \n􀂄 Monitoring \"static-free\" electronic workstations  \n􀂄 Measuring static build-up on webs in converting, laminating, and printing operations  \n􀂄 Checking grounds and bonding in dry particle/power transport systems  \n􀂄 Testing ionizer performance using optional charged plate adapter Monroe 282CPS  \n±5% of reading, + zero offset,±LSD  \nResponse Time  \n80 to 100 msec, 10 to 90%  \n©2020 Advanced Energy Industries, Inc.  \nMONROE ELECTROSTATIC FIELDMETERS 282IS AND 282A-1  \nTECHNICAL DATA  \n\n| Performance Specifications |  |  |  |\n| --- | --- | --- | --- |\n| Display | LCD 3 ½-digit with auto polarity readout, with hold and low battery indicators |  |  |\n| Range | 0 to ±19.99 kV at 1 in |  |  |\n|  | Voltages of 20kV and higher may be measured by increasing the distance to the target: |  |  |\n|  | kV | Distance | Multiply Reading By |\n|  | 0 to 40 | 4.0 in | 2 |\n|  | 0 to 80 | 8.5 in | 4 |\n| Accuracy | ±5% of reading, + zero offset, ± LSD |  |  |\n| Analog Output Amplitude | 1 Vsignal denotes 10 kV reading at 1 in for high impedance loads |  |  |\n| Response Time | Typical 80 to 100 msec 10 to 90% |  |  |\n\n\n| Mechanical Specifications |  |\n| --- | --- |\n| Dimensions (Lx W x H) | 6.1 x 10.7 x 2.3 cm (2.4 x 4.2 x 0.9 in) |\n| Weight | 0.14 kg (0.31 lb) with battery |\n| Jack Type | Accepts standard 2.5 mm (3/32 in) monaural phone plug |\n\n\n| Electrical Specifications |  |\n| --- | --- |\n| Battery | 9 V NEDA \\#1604 or equivalent |\n| Battery Life | 40 hours of normal use, with alkaline battery |\n\n\n| Environmental Specifications |  |\n| --- | --- |\n| Operating Temperature | 0 to 50°C (32 to 122°F) |\n| Relative Humidity | 0 to 85% noncondensing |\n| Ionized | Unaffected by ionized equipment |\n\n282IS Industral Approval and Certification1  \n\n| UL Certification Class I Groups A, B, C, D, and Class II Groups E, F, G, when powered by 9 V carbon zinc or zinc chloride battery NEDA 1604 or NEDA 1604D |\n| --- |\n| UL Certification for Class I, Division 1, Groups Cand D only when powered by 9 V alkaline NEDA 1604A |\n\n1 For UL approved, intrinsically safe meters,customers must specifically request Monroe 282IS when ordering.  \n[2 advancedenergy.com](2 advancedenergy.com)    \nMONROE ELECTROSTATIC FIELDMETERS 282IS AND 282A-1  \nEASY-TO-USE OPERATION  \n1. Turn the instrument ON.  \n2. Discharge your body by touching a grounded metal object.  \n3. Point the aperture toward a grounded object and press the ZERO button.  \n4. Aim the aperture toward the target surface at a distance of 1 in. Adjust the distance until the flashing beams of the LEDs inthe instrument converge. Read the voltage and polarity of the charged surface on the meter display.  \nFor additional measurements, repeat step four. To freeze the display, press the HOLD button. To read the voltages, start at a greater distanceto the target as given under specifica","cbCaidSszGL3smYg","https://ap.wps.com/l/cbCaidSszGL3smYg","pdf",183347,"English","# Product Highlights\n## Typical Applications\n# Technical Data\n## Performance Specifications\n## Mechanical Specifications\n## Electrical Specifications\n## Environmental Specifications\n# Easy-to-Use Operation\n# Maintenance","[{\"question\":\"How do the Monroe 282IS and 282A-1 meters perform non-contact measurements?\",\"answer\":\"They use a rangefinder LED beam that indicates when the instrument is at the correct distance from the target, enabling consistent readings of field strength and charged surface voltage up to 20 kV.\"},{\"question\":\"What accuracy and response time can be expected?\",\"answer\":\"Accuracy is listed as ±5% of reading with zero offset and ±LSD, and response time is typically 80 to 100 msec for 10 to 90% measurement response.\"},{\"question\":\"What maintenance is required to keep readings accurate and drift-free?\",\"answer\":\"Replace the battery annually or when BAT appears, and keep the sensor plate and the area around the aperture absolutely clean. Never touch the aperture with anything, even a cotton swab.\"}]","Monroe 282IS and 282A-1 Electrostatic Fieldmeters - Data Sheet | PDF"]