[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664829-105":59,"doc-detail-664829-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","module-for-humidity-and-temperature-oem-modules-technical-information","MODULE FOR HUMIDITY AND TEMPERATURE - OEM MODULES - Technical information","","Technical documentation for OEM humidity and temperature measurement modules based on airchip technology, providing adjusted sensor options with or without sensor frame. The modules deliver humidity and temperature with high measuring accuracy over -50…100 °C and 0…100 %RH, including dew and frost point calculations. It specifies analog output ranges, digital UART interface, supported protocols, calibration and scaling through ROTronic HW4 software, firmware update workflow, electrical-mechanical characteristics, and connector/pin descriptions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/module-for-humidity-and-temperature-oem-modules-technical-information/664829/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/module-for-humidity-and-temperature-oem-modules-technical-information/664829.png","ImageObject",300,407,{"name":92,"@type":93},"404brain","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What measurement range and accuracy do the OEM humidity and temperature modules support?","Question",{"text":112,"@type":113},"They cover -50…100 °C and 0…100 %RH, with non-condensing operation. Accuracy at 23 ±5 °C is specified as ±0.8 %RH / 0.1 K.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How do the modules output humidity and temperature signals?",{"text":117,"@type":113},"The standard configuration provides two freely scalable analog outputs (0…1 VDC) and a digital UART interface. Humidity, temperature, or dew/frost point can be assigned to either analog output using HW4 software.",{"name":119,"@type":110,"acceptedAnswer":120},"How are the modules adjusted, configured, and updated on a PC?",{"text":121,"@type":113},"ROPCB modules are adjusted at 10, 35, and 80 %RH with a temperature of 23 °C. For PC connection, the USB cable AC3001-X with open ends is soldered to the boards; via HW4 over USB, functions like adjustment, re-scaling, and firmware update become available.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664829,1793275091,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":24},1099529839291,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","MODULE FOR HUMIDITY AND TEMPERATURE  \nOEM MODULES   \nOEM MODULES FOR CUSTOMERSPECIFIC SOLUTIONS  \nWITH THE LATEST AIRCHIP TECHNOLOGY  \nINNOVATION IN HUMIDITY  \nAND TEMPERATURE MEASUREMENT  \n• Adjusted OEM module for humidity and temperature  \n• Highest possible measuring accuracy  \n• Range of application: -50…100 °C / 0…100 %RH  \n• Calculates dew/frost point  \n• Two freely scalable analog outputs  \n• Digital UART interface  \n• Available with or without sensor frame  \n• Customized versions on request  \nOEM MODULES  \nTECHNICAL INFORMATION  \nTypes  \nThe standard OEM humidity and temperature module comes in two types: one with sensor frame (HC2-ROPCB-F) and one without sensor frame (HC2-ROPCB) . Other types are available upon request.  \nAdjustment  \nEvery ROPCB OEM module is adjusted at 10, 35 and 80 %RHand a temperature of 23 °C.  \nProgramming / PC connection  \nThe modules are supplied without connectors. To connect the modules to a PC, the USB cable AC3001-X with open ends must be soldered to the printed circuit boards. As soon as the module has been connected to a PC and the HW4 software via a USB cable, many functions are available (e.g. adjustment, re-scaling, firmware update, etc.) .  \nOutput signal  \nThe standard configuration outputs a humidity and a temperature signal with a value of 0... 1 VDC at the two analog outputs. The default scale for the humidity signal is 0... 100 %RH and-40... 60 °C forthe temperature signal. The scales can be changed with the HW4 Software. It is also possible to assign the humidity, temperature or dew/ frost point to either of the analog outputs depending on the needs of the application.  \nHC2-ROPCB-F HC2-ROPCB  \n\n| Key features | HC2-ROPCB-(F) |\n| --- | --- |\n| Range of application | -50…100 °C / 0…100 %RH, non-condensing |\n| Humidity sensor | ROTRONIC HYGROMER® IN-1 |\n| Temperature sensor | Pt100 1/3 Class B |\n| Accuracy at 23 ±5 °C | ±0.8 %RH / 0.1 K |\n| Adjustment | At 10, 35 and 80 %RH @ 23 °C |\n| Long-term stability, humidity sensor | Better than 1 %RH / year |\n| Response time t63 | \u003C15 s |\n| Initialization time | \u003C3 s |\n| Supported software protocols | RO-ASCII, MODBUS*, I2C* |\n| Functions |  |\n| Evaluation software / Compatibility | ROTRONIC HW4** |\n| Logging function | 2000 data records. In loop or start-stop mode (function can be switched on with HW4 ** software) |\n| Temperature adjustment | 2 points with HW4** |\n| Humidity adjustment | Up to 100 points with HW4** |\n| Psychrometric calculations | Dew and frost point |\n| Output signals | 2x 0...1 VDC analog / 1x digital UART |\n| Firmware update | Via HW4 software |\n| Electrical specifications |  |\n| Power supply | +3.2...5.5 VDC / Recommended power supply 3.3 VDC\u003Cbr>If a different power supply is used, the module must be readjusted |\n| Current consumption | 4.5 mA at 3.3 VDC |\n| Output signals / Types | Analog / Digital |\n| Circuit type | 3/4 wire |\n| Analog output 1 | 0...1 VDC / [0...100](0...100) %RH |\n| Analog output 2 | 0...1 VDC / -[40...60](40...60) °C |\n| Resolution analog output | 16 bits |\n| Load per analog output | V-signal: ≥1 kΩ/V |\n| Digital interface options | UART / (Ethernet, RS-485, USB optionally via accessories) |\n| Polarity protection | No |\n| Mechanical specifications |  |\n| Housing material | No housing |\n| Cable connections | Solder flats |\n| Weight | Approx. 2 g |\n| Standards | EN 61000-6-4 & EN61000-6-2 |\n| FDA/GAMP compatibility | FDA CFR21 Part 11 and GAMP 5 |\n\n*Only in read mode  \n** The USB connection cable AC3001-x with open end must be soldered to the ROPCB.  \nDiagram  \n| OEM-RoPCB | VDD\u003Cbr>GND\u003Cbr>RXD\u003Cbr>TXD\u003Cbr>OUT1\u003Cbr>OUT2\u003Cbr>AGND |\n| --- | --- |\n\nConnection diagram  \n\n| Pin | Description | Front view | Rear view |\n| --- | --- | --- | --- |\n| 1 | VDD (power supply) | \u003Cbr>1 2 3 | \u003Cbr>7 6 5 4 |\n| 2 | GND (GND) |  |  |\n| 3 | RxD |  |  |\n| 4 | TxD |  |  |\n| 5 | OUT1 *(humidity 0…100 % rh) |  |  |\n| 6 | OUT2 *(temperature-40…60 °C) |  |  |\n| 7 | AGND |  |  |\n\n* Default setting  \nROTRONIC AG, Grindelstrasse ","cbCaibQJXPlh9Lyc","https://ap.wps.com/l/cbCaibQJXPlh9Lyc","pdf",1888583,"English","# Types\n## Adjustment\n## Programming / PC connection\n## Output signal\n# Key features\n## Supported software protocols\n## Output signals and firmware update\n## Electrical specifications\n## Mechanical specifications\n# Diagram\n## Connection diagram","[{\"question\":\"What measurement range and accuracy do the OEM humidity and temperature modules support?\",\"answer\":\"They cover -50…100 °C and 0…100 %RH, with non-condensing operation. Accuracy at 23 ±5 °C is specified as ±0.8 %RH / 0.1 K.\"},{\"question\":\"How do the modules output humidity and temperature signals?\",\"answer\":\"The standard configuration provides two freely scalable analog outputs (0…1 VDC) and a digital UART interface. Humidity, temperature, or dew/frost point can be assigned to either analog output using HW4 software.\"},{\"question\":\"How are the modules adjusted, configured, and updated on a PC?\",\"answer\":\"ROPCB modules are adjusted at 10, 35, and 80 %RH with a temperature of 23 °C. For PC connection, the USB cable AC3001-X with open ends is soldered to the boards; via HW4 over USB, functions like adjustment, re-scaling, and firmware update become available.\"}]","MODULE FOR HUMIDITY AND TEMPERATURE - OEM MODULES - Technical information | PDF"]