[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663466-105":59,"doc-detail-663466-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","modular-hydraulic-elevator-specifications-part-1-general","MODULAR HYDRAULIC ELEVATOR SPECIFICATIONS - PART 1 - GENERAL","","Modular hydraulic passenger elevator specifications define the required scope for furnishing, complete installation, and testing of hydraulic elevator systems shown on project drawings. The document details related technical sections, required submittals including shop drawings, engineering calculations, color and texture samples, maintenance manuals, and project record drawings. Quality assurance sets applicable safety and electrical standards, while warranty and maintenance specify replacement/repair responsibilities and service duration, coverage, exclusions, and maintenance activities to ensure compliant operation.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/modular-hydraulic-elevator-specifications-part-1-general/663466/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/modular-hydraulic-elevator-specifications-part-1-general/663466.png","ImageObject",300,407,{"name":92,"@type":93},"Syukur Setiap Hari","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What work scope is included in this section for modular hydraulic passenger elevators?","Question",{"text":112,"@type":113},"The section covers supply, complete installation, and testing of hydraulic passenger elevators indicated on the drawings, including cylinders, plungers, pumping units, oil storage tanks, controllers, guide rails, and entrances.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What submittals are required before installation and acceptance?",{"text":117,"@type":113},"Required submittals include complete shop drawings with control, power, and piping diagrams; engineering calculations for guide rail supporting brackets and splice/jack support locations; a complete list of items to be furnished; manufacturer-recommended installation procedures; finish samples; maintenance manuals; and project record drawings.",{"name":119,"@type":110,"acceptedAnswer":120},"What warranty and maintenance coverage must be provided?",{"text":121,"@type":113},"A special project warranty is required for defective materials and workmanship, with the warranty period defined as the earlier of 12 months from acceptance or 13 months from delivery. Full maintenance service for 12 months after acceptance must include monthly preventative maintenance plus repair/replacement of worn or defective parts and required lubrication, cleaning, and adjusting, excluding misuse, abuse, accidents, or neglect by others.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663466,1793228314,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},962093541965,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","MODULAR HYDRAULIC ELEVATOR SPECIFICATIONS  \nPART 1-GENERAL  \n1.0 SUMMARY  \nA. Section Includes: Supply and complete installation and testing of the hydraulic passenger elevators indicated on Drawings including cylinders, plungers, pumping units, oil storage tanks, controllers, guide rails, and entrances.  \nB. Related Sections  \n1. Excavating, Backfilling and Compacting for Utilities: Section 02222.  \n2. Elevator Pit Concrete; Cast-In-Place Concrete: Section 03300.  \n3. Resilient Flooring: Section 09650.  \n4. Heat and Smoke Sensing Devices: Division 15.  \n5. Power and Telephone Service to Elevator Control Panel: Division16 .  \n1.1 SUBMITTALS  \nA. Submit in accordance with Section 01300: Submittals and Section 01350:  \n1. Shop Drawings: Submit complete shop drawings, indicate control, power and piping diagrams. Include dimensioned plan of hoistway and machine room and full height section through hoistway.  \n2. Submit engineering calculations for the guide rail supporting brackets, splice locations, and jack(s) support beams and brackets.  \n3. Submit a complete list of all items to be furnished and installed under this Section.  \nB. Submit manufacturer’s recommended installation procedures which, when approved by the architect, shall be the basis for inspecting and accepting or rejecting actual installation.  \nC. Samples: Submit samples showing full range of colors and textures ofall finish materials specified including 2” x 3” sample of light-diffusing plastic ceiling panels.  \nD. Maintenance Manuals: Furnish to the inspector prior to final inspection, one bound maintenance manual containing specifications and instructions for the maintenance and adjustment of operating equipment and controls. Include with the special control directions, any special tools or testing equipment required.  \nE. Submit Project Record Drawings in accordance with Section 01720.  \n1. Submit one (1) set of 24” x 36” reproducible vellums.  \n1.2 QUALITY ASSURANCE  \nA. Work of this section shall conform to the following standards:  \n1. American National Standard Safety Code for Elevators (ANSI) A17.1  \n2. The National Electrical Code (NEC)  \n3. The American National Standard Specifications (ANSI) A117.1  \n4. “Minimum Passenger Elevator Requirements for Handicapped”, Third edition, as published by the National Elevator Industry, Inc.  \nA. Qualifications of Manufacturer: Elevator manufacturer shall be regularly engaged in the business of manufacturing elevators ofthe type specified and shall have a history of successful installations acceptable to the architect.  \nB. Qualifications of Installer: Provide a thoroughly qualified, trained and experienced person who shall be present at site and shall direct all work performed under this section.  \n1.3 PRODUCT HANDLING  \nA. Use all means necessary to protect the materials required by this section before, during and after installation and to protect the work form other trades. In the event of damage, immediately make all necessary repairs and replacements at no cost to the customer. All such costs shall be borne by the responsible party.  \n1.4 WARRANTY AND MAINTENANCE  \nA. Warranty: Provide special project warranty, signed by the contractor, installer and manufacturer, agreeing to replace/repair/restore defective materials and workmanship of elevator work during warranty period. “Defective” is hereby defined to include, but not byway of limitation, operation or control system failures, performances below required minimums, excessive wear, unusual deterioration or aging of materials or finishes, unsafe conditions, the need for excessive maintenance, abnormal noise or vibrations, and similar unusual, unexpected and unsatisfactory conditions.  \n1. The warranty period is for the earlier of 12 months starting on the date of acceptance by the State Elevator Inspector or 13 months from date of delivery of elevator unit(s) .  \nB. Maintenance Service: Provide full maintenance service by skilled, competent employees of elevat","cbCaiur7WcWZhShh","https://ap.wps.com/l/cbCaiur7WcWZhShh","pdf",142202,11,"English","# 1.0 SUMMARY\n## A. Section Includes\n## B. Related Sections\n# 1.1 SUBMITTALS\n## A. Shop Drawings and Engineering Calculations\n## B. Manufacturer Installation Procedures\n## C. Samples\n## D. Maintenance Manuals\n## E. Project Record Drawings\n# 1.2 QUALITY ASSURANCE\n## A. Standards\n## B. Manufacturer Qualifications\n## C. Installer Qualifications\n# 1.3 PRODUCT HANDLING\n# 1.4 WARRANTY AND MAINTENANCE\n## A. Warranty\n## B. Maintenance Service\n## C. Product Warranties\n# 2.0 MANUFACTURERS\n## A. Available Manufacturers\n# 2.1 SYSTEMS AND EQUIPMENT\n## A. General Characteristics","[{\"question\":\"What work scope is included in this section for modular hydraulic passenger elevators?\",\"answer\":\"The section covers supply, complete installation, and testing of hydraulic passenger elevators indicated on the drawings, including cylinders, plungers, pumping units, oil storage tanks, controllers, guide rails, and entrances.\"},{\"question\":\"What submittals are required before installation and acceptance?\",\"answer\":\"Required submittals include complete shop drawings with control, power, and piping diagrams; engineering calculations for guide rail supporting brackets and splice/jack support locations; a complete list of items to be furnished; manufacturer-recommended installation procedures; finish samples; maintenance manuals; and project record drawings.\"},{\"question\":\"What warranty and maintenance coverage must be provided?\",\"answer\":\"A special project warranty is required for defective materials and workmanship, with the warranty period defined as the earlier of 12 months from acceptance or 13 months from delivery. Full maintenance service for 12 months after acceptance must include monthly preventative maintenance plus repair/replacement of worn or defective parts and required lubrication, cleaning, and adjusting, excluding misuse, abuse, accidents, or neglect by others.\"}]","MODULAR HYDRAULIC ELEVATOR SPECIFICATIONS - PART 1 - GENERAL | PDF",28]