[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-639831-105":59,"doc-detail-639831-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","modular-cuber-prodigy-plus-e-series-installation-and-users-manual-installation","Modular Cuber Prodigy Plus E Series Installation and User’s Manual - Installation","","Installation and user guidance for the modular cuber Prodigy Plus E Series covering multiple air-cooled and water-cooled model numbers (C0322 through C1030). Provides product specifications including location, space, and environmental limits; minimum/maximum air and water temperatures, water pressure, and power supply voltage ranges. Includes model number decoding, cabinet layout references, and guidance on airflow, adapters, and field-installed options. Notes capacity impacts with clearance and emphasizes correct service access for safe, efficient operation.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/modular-cuber-prodigy-plus-e-series-installation-and-users-manual-installation/639831/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/modular-cuber-prodigy-plus-e-series-installation-and-users-manual-installation/639831.png","ImageObject",300,407,{"name":92,"@type":93},"sagouaw","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-26","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Where should the modular cuber be installed for safe operation?","Question",{"text":112,"@type":113},"Install indoors in a controlled environment. Air-cooled models discharge very warm air out the back and need space at the sides and back for airflow, while water-cooled models discharge warm water to the building’s drain.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What environmental limits must be followed?",{"text":117,"@type":113},"Air temperature must be between 50°F and 100°F, and water temperature between 40°F and 100°F. Water pressure should be between 20 psi and 80 psi.",{"name":119,"@type":110,"acceptedAnswer":120},"How are the model numbers interpreted?",{"text":121,"@type":113},"The manual explains that the model number characters describe the cuber, nominal ice capacity in 100s of pounds, cabinet width, cube size, condenser type (air or water cooled), electrical phase/voltage, and the series revision code.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},639831,1793029978,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},3985747862151,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Installation and User’s Manual for Modular Cuber  \nProdigy Plus E Series Models C0322, C0522, C0722, C0330, C0530, C0630, C0830 and C1030  \nC0322 through C1030 E Series Air and Water Cooled User Manual Introduction  \nThe design of this modular cuber is the result of years This installation and user manual is divided into of experience and testing. Standard features include three main sections: Installation, which provides front accessible indicator lights and on-off switches the trade person with the information needed to  \nthat provide the user with fast access to critical set up and install this product; Use and Operation,  \ninformation and easy operational control. which provides the user with the information to use  \nthe product; and Maintenance, which provides the  \nKeep this manual for future reference. user with the information needed keep it operating  \nefficiently.  \nContents  \nInstallation: Product Specifications .................................. Page 2  \nModel Number Description ...................................... Page 3  \nProduct Description & Electrical Requirements ............................ Page 4  \nC0322 and C0522 Cabinet Layout .................................. Page 5  \nC0722 Cabinet Layout ......................................... Page 6  \nC0330, C0530, C0630 Cabinet Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7  \nC0830 and C1030 Cabinet Layout .................................. Page 8  \nWater ................................................. Page 9  \nPanel Removal ............................................ Page 10  \nPlumbing Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11  \nElectrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 12  \nFinal Check List ............................................ Page 13  \nInitial Start Up ............................................. Page 14  \nAdjustments .............................................. Page 15  \nUse and Operation .......................................... Page 16  \nControl Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 17  \nCleaning, Sanitation and Maintenance ................................ Page 18  \nAir cooled condenser filter ....................................... Page 20  \nWhat to do before calling for service ................................. Page 21  \nNote any Caution or Warning symbols when they appear on the product or in this manual. They indicate potential hazards.  \nC0322 through C1030 E Series Air and Water Cooled User Manual Installation: Product Specifications  \nLocation Limitations:  \nThe product is designed to be installed indoors, in a controlled environment. Air cooled models discharge very warm air into the room out the back. Space must be allowed at the sides and back for air discharge. Water cooled models discharge warm water into the building’s drain.  \nSpace needs to be provided on both sides and above for service access.  \nSpace Limitations  \n\n| Note: Although the machine will function, ice capacity of air cooled machines will be significantly reduced with minimal clearance at the sides, back and top. |\n| --- |\n| Some space is recommended for service and maintenance purposes on all models. 6\" of space at the sides and back are required for adequate operation. To get the most capacity, locate the machine away from heat producing appliances and heating ducts, and allow 12-18 inches of space atthe sides and top for good air flow.\u003Cbr>Airflow is in the front, out the back. Attach a baffle kit to the back when an air cooled unit is installed with minimal side and top clearance. See the next page forkit numbers.\u003Cbr>|\n\nEnvironmental Limitations  \n\n|  | Minimum | Maximum |\n| --- | --- | --- |\n| Air temperature | 50oF. | 100oF. |\n| Water temperature | 40oF. | 100oF. |\n| Water pressure | 20 psi | 80 psi |\n\nPower supply – acceptable voltage range","cbCaip9FdNWGvNeq","https://ap.wps.com/l/cbCaip9FdNWGvNeq","pdf",3471524,23,"English","# Installation: Product Specifications\n## Location Limitations\n## Environmental Limitations\n## Power Supply and Warranty Information\n## Product Information and Air Flow\n# Model Number Description\n## Options and Side Air Flow Kits\n## Bin Applications-Adapter Information","[{\"question\":\"Where should the modular cuber be installed for safe operation?\",\"answer\":\"Install indoors in a controlled environment. Air-cooled models discharge very warm air out the back and need space at the sides and back for airflow, while water-cooled models discharge warm water to the building’s drain.\"},{\"question\":\"What environmental limits must be followed?\",\"answer\":\"Air temperature must be between 50°F and 100°F, and water temperature between 40°F and 100°F. Water pressure should be between 20 psi and 80 psi.\"},{\"question\":\"How are the model numbers interpreted?\",\"answer\":\"The manual explains that the model number characters describe the cuber, nominal ice capacity in 100s of pounds, cabinet width, cube size, condenser type (air or water cooled), electrical phase/voltage, and the series revision code.\"}]","Modular Cuber Prodigy Plus E Series Installation and User’s Manual - Installation | PDF",1792705605,58]