[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-361789-105":59,"doc-detail-361789-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","modeling-and-testing-of-steel-emt-imc-and-rigid-grc-conduit-part-1-final-report","Modeling and Testing of Steel EMT, IMC, and RIGID (GRC) Conduit - Part 1 - Final Report","","Final report submitted to NEMA detailing modeling and testing of steel EMT, IMC, and RIGID (GRC) conduit, prepared by researchers from Georgia Institute of Technology. The study addresses fault-current behavior where steel conduit can carry return fault current or act as the only return path, treating this as a worst-case condition. The document includes field test data and computer program modeling, with instrumentation validation emphasized. It defines key electrical and grounding terms and introduces the research motivation linked to increasing fault current levels and grounding requirements.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/modeling-and-testing-of-steel-emt-imc-and-rigid-grc-conduit-part-1-final-report/361789/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/modeling-and-testing-of-steel-emt-imc-and-rigid-grc-conduit-part-1-final-report/361789.png","ImageObject",300,407,{"name":92,"@type":93},"Jordan Avery","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-14","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the report’s focus regarding steel conduit in fault conditions?","Question",{"text":112,"@type":113},"The report focuses on the performance of steel conduit as the equipment grounding conductor, especially scenarios where the conduit carries most or all return fault current as the worst case.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What types of information does the report include?",{"text":117,"@type":113},"The report contains field test data and results obtained with a model computer program, along with efforts to ensure accurate instrumentation and validate the computer program.",{"name":119,"@type":110,"acceptedAnswer":120},"Why does the report reexamine existing grounding parameters?",{"text":121,"@type":113},"Fault current levels have increased, creating greater protection and safety concerns, so the study evaluates the performance of steel EMT, IMC, or RIGID conduit during faults in secondary distribution systems.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},361789,1790668258,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":24,"preview_urls":146},1099523882367,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","File: IR_NEMA. DOC  \nFinal Report  \nSubmitted to  \nNEMA  \nfor  \nModeling and Testing of Steel EMT, IMC and RIGID (GRC) Conduit  \nPart 1  \nPrepared by  \nA. P. Sakis Meliopoulos  \nElias N. Glytsis  \nSchool of Electrical and Computer Engineering  \nGeorgia Institute of Technology  \nAtlanta, Georgia 30332  \nMay 1994  \nCopyright 1994  \nGeorgia Tech Research Institute  \nAtlanta, Georgia 30332-0415  \nAll Rights Reserved  \nDisclaimer  \nThis report contains (a) field test data and (b) results obtained with a model computer program. Every effort has been made to ensure accurate instrumentation for the field tests and to validate the computer program. However, the authors disclaim any responsibility relative to the utilization of these results.  \nTable of Contents  \nGlossary____________________________________________________________________ 1  \nModeling and Testing of Steel EMT, IMC, and RIGID (GRC) Conduit _________ 2  \n1.0 Introduction ____________________________________________________________ 2  \n2.0 Determination of Steel Conduit Material Parameters _______________________ 7  \n3.0 Computer Modeling of Steel Conduit Enclosed Power Systems_____________ 9  \n4.0 Simulation of Steel EMT, IMC and RIGID Conduit Enclosed Power Systems_ 13  \n4.1 Effect of Electric Current Magnitude on Maximum Allowable Length ________________ 17  \n5.0 High Current Laboratory Tests ___________________________________________ 23  \n6.0 Comparisons and Discussion ___________________________________________ 34  \n7.0 Summary and Conclusions______________________________________________ 37  \n8.0 References ____________________________________________________________ 39  \nEMT  \nIMC  \nGRC  \nArc Voltage, Varc  \nShort Circuit Current  \nOvercurrent Protective Device, OPD  \nMinimum Ground Fault Current, IGFC  \nMaximum Allowable Length, Lmax  \nPermeability  \nGlossary  \nElectrical Metallic Tubing  \nIntermediate Metal Conduit  \nGalvanized Rigid Conduit  \nThe voltage across the electric arc between two phase conductors or between a phase conductor and a grounding conductor.  \nThe electric current flowing in a circuit whenever a short circuit is applied.  \nA protective Device which is designed to disconnect a circuit whenever the electric current exceeds a certain value.  \nThe minimum ground fault current which will result in the safe operation of an overcurrent protective device within specified time. This value is normally selected as a multiple of the overcurrent protective device rating.  \nThe length of the conduit which will result in a total ground fault current equal to or higher than a specified value, IGFC, with an arc voltage equal or lower than a specified value, Varc .  \nThe property of the material which equals the ratio of magnetic flux density to the magnetic field intensity.  \nModeling and Testing of Steel EMT, IMC, and RIGID (GRC) Conduit  \n1.0 Introduction  \nSteel conduit is widely used in secondary power distribution systems, indoors and outdoors. Systems are designed in such a way that the steel conduit does not carry any appreciable electric current under normal operating conditions. Under certain fault conditions, the steel conduit will carry most of the return fault current or in some cases it will be the only return path of the fault current to the source. In reality, the conduit is only one of fault current return paths as illustrated in Figure 1.1a. Specifically, in a practical system the fault current will split among several parallel paths in returning to the source. As an example, for a phase to neutral to ground fault in the bottom conduit of Figure 1.1a the fault current will return to the source through the conduit (path BA), neutral (path DC), and facility ground (path FE) . For a phase to conduit fault, the fault current will return to the source through the conduit and facility ground. It is possible that for a phase to conduit fault the only return path for the fault current is the conduit. This is possible for the systems illustrated in F","cbCainDor6mJLEec","https://ap.wps.com/l/cbCainDor6mJLEec","pdf",316366,43,"English","# Glossary\n# Modeling and Testing of Steel EMT, IMC, and RIGID (GRC) Conduit\n## 1.0 Introduction\n## 2.0 Determination of Steel Conduit Material Parameters\n## 3.0 Computer Modeling of Steel Conduit Enclosed Power Systems\n## 4.0 Simulation of Steel EMT, IMC and RIGID Conduit Enclosed Power Systems\n## 5.0 High Current Laboratory Tests\n## 6.0 Comparisons and Discussion\n## 7.0 Summary and Conclusions\n## 8.0 References","[{\"question\":\"What is the report’s focus regarding steel conduit in fault conditions?\",\"answer\":\"The report focuses on the performance of steel conduit as the equipment grounding conductor, especially scenarios where the conduit carries most or all return fault current as the worst case.\"},{\"question\":\"What types of information does the report include?\",\"answer\":\"The report contains field test data and results obtained with a model computer program, along with efforts to ensure accurate instrumentation and validate the computer program.\"},{\"question\":\"Why does the report reexamine existing grounding parameters?\",\"answer\":\"Fault current levels have increased, creating greater protection and safety concerns, so the study evaluates the performance of steel EMT, IMC, or RIGID conduit during faults in secondary distribution systems.\"}]","Modeling and Testing of Steel EMT, IMC, and RIGID (GRC) Conduit - Part 1 - Final Report | PDF",1790145593,108,[147,151,155,159,163],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/8b02383f04f8c7c3b7226c92c7f08833.webp",983,1272,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/62db008fee5f5e469882484cb483d258.webp",982,1270,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/64442ba207c2ea2b6114a0fad5e75245.webp",981,1269,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/c4764097983459fd4806c442f58f2b8d.webp",980,1268,{"page_no":24,"url":164,"width":165,"height":166},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/fe6aa831c76ee6a3d4815b461c754f6c.webp",979,1267]