[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-662106-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-662106-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","mnl2103-rcs-24-cheeser-station-manual-operator-manual-flammable-refrigerant-safety","MNL2103-RCS-24-Cheeser-Station-Manual - Operator Manual - Flammable Refrigerant Safety","","Operator manual for the Randell RCS-24-WS and RCS-24 24” Cheeser Station with integral scale (model shown) and the standard version. Provides safety requirements and warnings for R290 flammable refrigerant, including proper handling to avoid damaging refrigerant tubing, installation guidance, and limitations that can void warranty. Includes equipment identification, part number PP MNL2103 rev. C (03/24), serial number location, and key specifications such as dimensions, power cycle details, electrical plug type, and shipping weight, plus notices about record retention and product changes.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/mnl2103-rcs-24-cheeser-station-manual-operator-manual-flammable-refrigerant-safety/662106/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/mnl2103-rcs-24-cheeser-station-manual-operator-manual-flammable-refrigerant-safety/662106.png","ImageObject",300,407,{"name":42,"@type":43},"Finn","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":30},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"Where is the serial number located on the unit?","Question",{"text":62,"@type":63},"The serial number is located on the right side inside the base cabinet behind the grilled hinged door.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What refrigerant hazard warnings are included in the manual?",{"text":67,"@type":63},"The manual warns about R290 flammable refrigerant and emphasizes careful handling to avoid damaging refrigerant tubing, since puncture or improper handling increases leak and fire/explosion risk.",{"name":69,"@type":60,"acceptedAnswer":70},"What can cause the warranty to be void?",{"text":71,"@type":63},"Failure to follow installation guidelines and recommended procedures may void the warranty, and exceeding the voltage limits for the unit data tag can also void warranty.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},662106,1793199700,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},7,40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":106,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":30,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":79,"read_time":144},34359740700684,"https://ap-avatar.wpscdn.com/avatar/1f400023980c374ae676?_k=1777273430885731487","| | |\n| --- | --- |\n| OPERATOR MANUAL\u003Cbr>IMPORTANT INFORMATION, KEEP FOR OPERATOR\u003Cbr>\u003Cbr>888-994-7636, fax 888-864-7636 [unifiedbrands.net](unifiedbrands.net) |  |\n\nTHIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.  \nFOR YOUR SAFETY Do not store or use gasoline or other flammable vaporsand liquids in the vicinity of this or any other appliance.  \nWARNING R290 flammable refrigerant in use. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.  \nNOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed damage. Randell suggests that if you are suspicious of damage to make a notation on the delivery receipt. It will be the responsibility of the consignee to file a claim with the carrier. We recommend that you do so at once.  \nManufacture Service/Questions 888-994-7636.  \nEQUIPMENT DESCRIPTION  \nPART NUMBER PP MNL2103, REV. C (03/24)  \nThis manual provides information for:  \nRCS-24-WS 24” CHEESER STATION® WITH INTEGRAL SCALE (SHOWN)  \nRCS-24 24” CHEESER STATION®  \nUS Patent No. D960,641 and additional patents pending.  \nRETAIN THIS MANUAL FOR FUTURE REFERENCE  \nNOTICE: Due to a continuous program of product improvement, Randell reserves the right to make changes in design and specifications without prior notice.  \nNOTICE: Please read the entire manual carefully before installation. If certain recommended procedures are not followed, warranty claims will be denied.  \nMODELNUMBER   SERIAL NUMBER    \nINSTALLATION DATE    \nThe serial number is located on the right side inside the base cabinet behind the grilled hinged door. An example is shown here.  \n| MODEL | LENGTH | DEPTH* | HEIGHT |  | INTEGRATED\u003Cbr>SCALE | CHEESE BIN\u003Cbr>STORAGE CU. FT. | HP | VOLT/CYCLE/\u003Cbr>PHASE | AMPS | NEMA\u003Cbr>PLUG | SHIP WT. |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  | WORK SURFACE | REAR OF UNIT |  |  |  |  |  |  |  |\n| RCS-24-WS | 24” | 33” | 36” | 41” | YES | 1.25 | 1/4 | 115/60/1 | 1.8 | 5-15P | 180 |\n| RCS-24 | 24” | 33” | 36” | 41” | NO | 1.25 | 1/4 | 115/60/1 | 1.8 | 5-15P | 180 |\n\n*Depth = 34” with 1” standoff bumpers  \nInformation contained in this document is known to be current and accurate at the time of printing/creation. Reference our product line website for the most updated product information and specifications. © 2024 Electrolux Professional, Inc. All Rights Reserved.  \nIMPORTANT-READ FIRST-IMPORTANT  \nEXTERIOR OF UNIT  \n\n| CAUTION | MISE EN GARDE RISQUE D’INCENDIE OUD’EXPLOSION. ÉLIMINER (or DISPOSER) CORRECTEMENT CONFORMÉMENT AUX RÉGLEMENTATIONSFÉDÉRALES OU LOCALES. RÉFRIGÉRANT INFLAMMABLE UTILISÉ.\u003Cbr>PP LBL1704 REV B |\n| --- | --- |\n| RISK OF FIRE OR EXPLOSION. DISPOSE OF PROPERLY IN ACCORDANCE WITH FEDERAL OR LOCAL REGULATIONS.\u003Cbr>FLAMMABLE REFRIGERANT USED. |  |\n| PRECAUCIÓN RIESGO DE INCENDIOO EXPLOSIÓN. DESÉCHELOADECUADAMENTE CONFORMEA REGLAMENTOS FEDERALES O LOCALES. REFRIGERANTE INFLAMABLE UTILIZADO. SB6.1.4 |  |\n\nNEAR EXPOSED REFRIGERANT TUBING  \n\n| CAUTION | MISE EN GARDE RISQUE D’INCENDIE OUD’EXPLOSION EN RAISON\u003Cbr>DE LA PERFORATION DU TUBE RÉFRIGÉRANT; SUIVEZ ATTENTIVEMENT LES INSTRUCTIONS DE MANIPULATION. RÉFRIGÉRANT INFLAMMABLE UTILISÉ. |\n| --- | --- |\n| RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOW HANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED. |  |\n| PRECAUCIÓN RIESGO DE INCENDIOO EXPLOSIÓN DEBIDO A LA PERFORACIÓN DE LA TUBERÍA DE REFRIGERANTE; SIGA CUIDADOSAMENTE LAS INSTRUCCIONES DE MANEJO. REFRIGERANTE SB6.1.5\u003Cbr>INFLAMABLE UTILIZADO. PP LBL1705 REV B |  |\n\nNEAR MACHINE COMPARTMENT AND NAMEPLATE  \n\n| DANGER | DANGER RISQUE D’INCENDIE OU\u003Cbr>D’EXPLOSION. ","cbCaibBn4AtUiQGE","https://ap.wps.com/l/cbCaibBn4AtUiQGE","pdf",4560003,17,"English","# Equipment Description\n## Safety Information and Warnings\n# Installation\n## Serial Number Location\n# Specifications\n## Electrical and Shipping Data","[{\"question\":\"Where is the serial number located on the unit?\",\"answer\":\"The serial number is located on the right side inside the base cabinet behind the grilled hinged door.\"},{\"question\":\"What refrigerant hazard warnings are included in the manual?\",\"answer\":\"The manual warns about R290 flammable refrigerant and emphasizes careful handling to avoid damaging refrigerant tubing, since puncture or improper handling increases leak and fire/explosion risk.\"},{\"question\":\"What can cause the warranty to be void?\",\"answer\":\"Failure to follow installation guidelines and recommended procedures may void the warranty, and exceeding the voltage limits for the unit data tag can also void warranty.\"}]","MNL2103-RCS-24-Cheeser-Station-Manual - Operator Manual - Flammable Refrigerant Safety | PDF",43]