[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-661719-105":59,"doc-detail-661719-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","ml40190-1-owners-manual-pdaatf-max-controller","ML40190-1 - Owner’s Manual - PDA/ATF-MAX Controller","","Owner’s manual for the PDA/ATF-MAX dual purpose controller used to monitor differential pressure with an alarm indicator and to automatically control a flush valve of a Thompson strainer. Covers safety precautions, system components, and controller interface details, including the screen and keypad access. Provides step-by-step startup, automatic flushing logic, consecutive flush alarm behavior and reset methods, and menu navigation. Explains how to change parameter values and describes key menu screens such as the power up and manifold pressure displays.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ml40190-1-owners-manual-pdaatf-max-controller/661719/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ml40190-1-owners-manual-pdaatf-max-controller/661719.png","ImageObject",300,407,{"name":92,"@type":93},"Malam Tenang","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety steps must be followed before installation or operation?","Question",{"text":112,"@type":113},"Ensure appropriate personnel read the owner’s manual prior to installation and/or operation. Follow safety precautions to avoid personal injury or product damage.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the controller initiate automatic flushing under normal operation?",{"text":117,"@type":113},"It initiates timed flushes on a periodic schedule and also initiates timed flushes when differential pressure reaches the configured setpoint.",{"name":119,"@type":110,"acceptedAnswer":120},"What triggers the consecutive flush alarm, and how is it reset?",{"text":121,"@type":113},"If three consecutive flushing operations are detected, a consecutive flush alarm triggers and prevents further flush cycles until cleared. After correcting the cause, press the red ESC button while a status screen is displayed, or use the optional Customer’s Remote Reset input (Input iB).","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},661719,1793176693,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},962093532863,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","OWNER’S MANUAL  \nTable of Contents  \nI. Safety Considerations..…………………………………….. 1  \nII. Description………………...…...………………...…………… 1  \nIII. System Overview……………………………………………. 2  \nIV. Operation……………………………………………...………. 3  \nV. Menu Screens……………..…..……………………………… 4  \nVI. Layout & I/O Configuration….………….…………….. 8  \nVII. Electrical Connections…………………………………… 9  \nVIII. Electrical Schematic……………………………………… 10  \nIX. Limited Warranty & Contact Info…………………… 11  \nI. SAFETY CONSIDERATIONS  \n\n|  | GENERAL WARNING |\n| --- | --- |\n| | Ensure all appropriate personnel read owner’s manual prior to installation and/or operation of controller. Failure to Comply with instructions and safety precautions could lead to personal injury or product damage. Please call and ask to speak with one of our customer service representatives if there are any questions. |\n|  | CAUTION |\n|  | Disconnect controller from power source before servicing or removing cover. |\n\nII. DESCRIPTION  \nThe PDA/ATF-MAX is a dual purpose controller for both monitoring the pressure differential with alarm indicator and automatically controlling the flush valve of a Thompson strainer.  \nIII. SYSTEM OVERVIEW  \nThe PDA/ATF-MAX system consists of the following primary components:  \nA) PDA/ATF-MAX controller  \nB) Power supply  \nC) Transducer / Wiring assembly  \nD) Mounting bracket  \nE) Flush valve assembly  \nThe controller interface contains the controller screen and keypad interface as shown. The clear cover provides protection for the controller and can be opened with the two latches on the side of the controller housing to access the keypad.  \nA) Controller Screen  \nIV. OPERATION  \nStartup  \n1) Plug in the power plug into a standard 115VAC wall outlet  \n2) Upon power-up, the company information screen will be shown for 15 seconds.  \n3) After 15 seconds, the screen will change to the manifold pressure screen and will begin monitoring differential pressure across the strainer.  \nAutomatic Flushing  \nUnder normal operation, a timed flush will be initiated on a periodic schedule defined by the PDA/ATF-MAX programmed setting.(every 24 hours per factory setting) .  \nIn addition, a timed flush will be initiated when the differential pressure reaches the setpoint defined by the PDA/ATF-MAX settings.  \nSee the MENU SCREENS section for information on changing factory settings.  \nConsecutive Flush Alarm  \nIf three consecutive flushing operations are detected by the PDA/ATF-MAX, a consecutive flush alarm will be triggered and no additional flush cycles will be initiated until the alarm is cleared.  \nTo reset the Consecutive Flush Alarm, first, correct the cause of the alarm, then push the red ESC button on the controller while a Status screen is displayed. The optional Customer’s Remote Reset input, Input iB, allows for a remote reset of the Consecutive Flush Alarm.  \nScrolling through Menu Screens  \nThe PDA/ATF-MAX allows the operator to scroll through a selection of menu screens by pressing the A or B buttons. Press Ato scroll backward to the previous menu or press B to scroll forward to the next menu. The LCD backlight will automatically turn on for 5 minutes when a button is pressed, thus allowing the operator to easily view the menus in low light situations.  \nChanging Parameter Values  \nTo change an adjustable value, first scroll to the appropriate menu screen using the A or B button. Follow the directions below to modify the value.  \n1) The current selected value will show flashing blocks. Use the + or-keys to select another value if desired.  \n2) Press OK on the selected value. The value will change from flashing blocks to flashing numbers. Flashing blocks indicate the value is locked into memory. Flashing numbers indicates the value is unlocked and can be changed.  \n3) Press the + or-buttons to change the value. Holding the + or-button will allow the value to increase at a faster rate after the first 10 increments have passed.  \n4) When finished, press OK to save the change to memory. The valu","cbCairNFnEpYxVVc","https://ap.wps.com/l/cbCairNFnEpYxVVc","pdf",1747973,11,"English","# Safety Considerations\n# Description\n# System Overview\n# Operation\n## Startup\n## Automatic Flushing\n## Consecutive Flush Alarm\n## Scrolling through Menu Screens\n## Changing Parameter Values\n# Menu Screens\n## Power Up Screen\n## Manifold Pressure Screen\n## Status Screens","[{\"question\":\"What safety steps must be followed before installation or operation?\",\"answer\":\"Ensure appropriate personnel read the owner’s manual prior to installation and/or operation. Follow safety precautions to avoid personal injury or product damage.\"},{\"question\":\"How does the controller initiate automatic flushing under normal operation?\",\"answer\":\"It initiates timed flushes on a periodic schedule and also initiates timed flushes when differential pressure reaches the configured setpoint.\"},{\"question\":\"What triggers the consecutive flush alarm, and how is it reset?\",\"answer\":\"If three consecutive flushing operations are detected, a consecutive flush alarm triggers and prevents further flush cycles until cleared. After correcting the cause, press the red ESC button while a status screen is displayed, or use the optional Customer’s Remote Reset input (Input iB).\"}]","ML40190-1 - Owner’s Manual - PDA/ATF-MAX Controller | PDF",28]