[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-349253-105":59,"doc-detail-349253-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","miniaturized-shared-aperture-multiband-antenna-for-wireless-biomedical-applications-research-article","Miniaturized shared aperture multiband antenna for wireless biomedical applications - Research article","","This study presents a compact folded dipole multiband shared-aperture antenna for wireless biomedical applications, operating across sub-1 and sub-6 GHz bands on a single FR-4 substrate. The design uses shared-aperture geometry with horizontally and vertically oriented coaxial feeds on the back layer to enable simultaneous multi-band operation while reducing size. A miniaturization approach based on lumped element integration cuts dimensionality by 80% and preserves function. An integrated measurement subsystem using a cancer-related analyte reports a detectable spectral change at 5.7 GHz, supporting an oncogenic diagnostic indicator in healthcare settings.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/miniaturized-shared-aperture-multiband-antenna-for-wireless-biomedical-applications-research-article/349253/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/miniaturized-shared-aperture-multiband-antenna-for-wireless-biomedical-applications-research-article/349253.png","ImageObject",300,407,{"name":92,"@type":93},"eBook King","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28","2026-09-22",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What frequency bands does the proposed antenna cover?","Question",{"text":113,"@type":114},"It operates in the bands of 0.431-0.435 GHz, 4.75-4.96 GHz, and 5.64-5.88 GHz, enabling coverage across sub-1 and sub-6 GHz ranges.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the shared-aperture design help achieve multiband performance?",{"text":118,"@type":114},"The antenna uses a common aperture that lets multiple radiating elements or functions share physical space, supporting multiband operation while reducing size and complexity.",{"name":120,"@type":111,"acceptedAnswer":121},"What measurement feature is included for biomedical sensing?",{"text":122,"@type":114},"A built-in measurement subsystem incorporates a cancer-related analyte and yields a detectable spectral change at 5.7 GHz, intended as an oncogenic presence diagnostic indicator.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},349253,1790560161,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},962088006270,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","OPEN ACCESS  \nCitation: Chishti AR, Aziz A, Abbasi MN, AAljaloud K, Alqahtani AH, Hussain R (2026) Miniaturized shared aperture multiband antenna for wireless biomedical applications. PLoSOne 21(6): e0349676. [https://doi.org/10.1371/](https://doi.org/10.1371/)[ ](https://doi.org/10.1371/)[journal.pone.0349676](journal.pone.0349676)  \nEditor: Muhammad Zubair, University of Leicester, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND  \nReceived: September 20, 2025  \nAccepted: May 4, 2026  \nPublished: June 4, 2026  \nCopyright: © 2026 Chishti et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.  \nData availability statement: All relevant data are included within the paper.  \nFunding: The author(s) received no specific funding for this work.  \nRESEARCH ARTICLE  \nMiniaturized shared aperture multiband antenna for wireless biomedical applications  \nAbdul Rehman Chishti1*, Abdul Aziz1, Muhammad Nawaz Abbasi1, Khaled A. Aljaloud2*, Ali H. Alqahtani2, Rifaqat Hussain3  \n1 Department of Information and Communication Engineering, Faculty of Engineering, The Islamia University of Bahawalpur, Bahawalpur, Pakistan, 2 College of Engineering, Muzahimiyah Branch, King Saud University, Riyadh, Saudi Arabia, 3 Antenna and Electromagnetics Research Group, School of Electronic Engineering and Computer Science, Queen Mary University of London, London, United Kingdom  \n* [rehman.chishti@iub.edu.pk](rehman.chishti@iub.edu.pk) (ARC); [kaljaloud@ksu.edu.sa](kaljaloud@ksu.edu.sa) (KAA)  \nAbstract  \nThis study presents a compact, folded dipole multiband shared-aperture antenna that operates effectively across both sub-1 and sub-6 GHz frequency bands using a single radiating structure—constructed on an FR-4 substrate.  \nDesign measures 16.40 × 10.50 × 1.52mm3 (0.0386λ × 0.0247λ × 0.0036λ),(0.431λ × 0.276λ × 0.040λ), (0.512λ × 0.328λ × 0.048λ), resonates at the bands of 0.431-0.435 GHz, 4.75-4.96 GHz, and 5.64-5.88 GHz, thus having a flexibility to a wide range of applications. The proposed antenna is a folded dipole built on the upper layer, and the coaxial feeds run to horizontally and vertically oriented strips on the backside layer. This arrangement enables simultaneous use along with various frequency bands in a single physical structure by taking advantage of shared-aperture concept thereby achieving space economy and operational efficiency. By applying a miniaturization plan based on lumped element integration, the radiating system guarantees a reduction of 80% in the dimensionality, and remains functionally intact. Besides, the integrated measurement subsystem incorporates a cancer-related analyte which mimics the electromagnetic nature of cancerous cellular organisms and thus a detectable spectral change at 5.7 GHz. The implication of this phenomenon is the initiation of an oncogenic presence diagnostic indicator. The concomitant capability of operating in multiple bands and smaller footprint make the antenna especially favourable to use in the context of operating in healthcare infrastructures for biomedical platforms along with wireless communication applications.  \nIntroduction  \nAntennas are an important part of modern world of wireless communication [ 1–5], especially 5G communication. Working in specific frequencies, they maintain constant connections of the devices in different settings, at home, at workplace, or on the  \nPLOS One | [https://doi.org/10.1371/journal.pone.0349676](https://doi.org/10.1371/journal.pone.0349676) June 4, 2026 1 / 17  \nCompeting interests: NO authors have competing interests.  \nmove. Recent advancements like MIMO and beamforming improve signal strength and reliability even more, particularly in cities with a large population density with numerous devices competing to get the communication resources.  \nThe recent developments","cbCaieiQrLbQeuhe","https://ap.wps.com/l/cbCaieiQrLbQeuhe","pdf",3597996,17,"English","# Abstract\n# Introduction\n# Antenna design concept: shared aperture multiband operation\n# Miniaturization and impedance-matching considerations\n# Research design and expected biomedical implications","[{\"question\":\"What frequency bands does the proposed antenna cover?\",\"answer\":\"It operates in the bands of 0.431-0.435 GHz, 4.75-4.96 GHz, and 5.64-5.88 GHz, enabling coverage across sub-1 and sub-6 GHz ranges.\"},{\"question\":\"How does the shared-aperture design help achieve multiband performance?\",\"answer\":\"The antenna uses a common aperture that lets multiple radiating elements or functions share physical space, supporting multiband operation while reducing size and complexity.\"},{\"question\":\"What measurement feature is included for biomedical sensing?\",\"answer\":\"A built-in measurement subsystem incorporates a cancer-related analyte and yields a detectable spectral change at 5.7 GHz, intended as an oncogenic presence diagnostic indicator.\"}]","Miniaturized shared aperture multiband antenna for wireless biomedical applications - Research article | PDF",1790082451,43,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/cee45b8cf166129695927ae7b987e387.webp",983,1272,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/35d86d8e1298d4c50fc894d0bd057cb6.webp",982,1270,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/1d82100ff5b1e78349f713188829ca38.webp",981,1269,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/d49c4e13fa0b23e968c555b0d163bb47.webp",980,1268]