[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-515684-105":59,"doc-detail-515684-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","miniature-transducer-using-pnn-pzt-based-ceramic-for-intravascular-ultrasound","Miniature Transducer Using PNN-PZT-based Ceramic for Intravascular Ultrasound","","Development and performance evaluation of a high-frequency miniature ultrasonic transducer for intravascular imaging is presented using a Pb(Ni1/3Nb2/3)O3-Pb(Zr0.3Ti0.7)O3 (PNN-PZT-based) ceramic. The ceramic shows ultrahigh relative clamped dielectric permittivity (ƐS/Ɛ0 = 3409) and strong electromechanical coupling (kt = 0.60). A 42-MHz side-looking probe with a 0.33 mm × 0.33 mm miniature aperture is designed and fabricated, achieving 79% wide-6 dB bandwidth and -19.6 dB insertion loss. Imaging performance is validated via axial resolution of 36 μm and lateral resolution of 141 μm using a 13-μm tungsten wire phantom, with ex vivo IVUS imaging of a porcine coronary artery demonstrating strong potential for high-resolution miniature transducers.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/miniature-transducer-using-pnn-pzt-based-ceramic-for-intravascular-ultrasound/515684/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/miniature-transducer-using-pnn-pzt-based-ceramic-for-intravascular-ultrasound/515684.png","ImageObject",300,407,{"name":92,"@type":93},"Ivy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-10-06",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What material is used to build the miniature ultrasonic transducer?","Question",{"text":112,"@type":113},"The transducer is based on a PNN-PZT-based ceramic, specifically Pb(Ni1/3Nb2/3)O3-Pb(Zr0.3Ti0.7)O3, designed for high-frequency intravascular imaging.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the main electrical and bandwidth performance metrics reported?",{"text":117,"@type":113},"The ceramic exhibits ultrahigh relative clamped dielectric permittivity (ƐS/Ɛ0 = 3409) and electromechanical coupling kt = 0.60. The fabricated 42-MHz probe achieves 79% wide-6 dB bandwidth and -19.6 dB insertion loss.",{"name":119,"@type":110,"acceptedAnswer":120},"How is imaging resolution evaluated and what imaging test is performed?",{"text":121,"@type":113},"Resolution is measured using a 13-μm tungsten wire phantom, yielding 36 μm axial resolution and 141 μm lateral resolution. Ex vivo IVUS imaging of a porcine coronary artery demonstrates the miniature transducer’s imaging capability.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},515684,1791417486,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},549758252649,"https://ap-avatar.wpscdn.com/avatar/8000253669c5317157?_k=1778319167496531819","This article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication. Citation information: DOI 10.1109/TUFFC.2019.2906652, IEEE  \nTransactions on Ultrasonics, Ferroelectrics, and Frequency Control  \n> REPLACE THIS LINE WITH YOUR PAPER IDENTIFICATION NUMBER (DOUBLE-CLICK HERE TO EDIT) \u003C 1  \nMiniature Transducer Using PNN-PZT-based Ceramic for Intravascular Ultrasound  \nQi Zhang, Student Member, IEEE, Xuming Pang, Zhiqiang Zhang, Min Su, Jiehan Hong, Hairong Zheng, Senior Member, IEEE, Weibao Qiu, Senior Member, IEEE, Kwok Ho Lam, Senior Member,  \nIEEE  \nAbstract—In this work, the development and performance evaluation of a high-frequency miniature ultrasonic transducer based on a Pb(Ni1/3Nb2/3)O3-Pb(Zr0.3Ti0.7)O3 (PNN-PZT-based) ceramic for intravascular imaging application are reported. The fabricated PNN-PZT-based ceramic possesses ultrahigh relative clamped dielectric permittivity (ԑS/ԑ0 = 3409) and high electromechanical coupling capability (kt = 0.60). A 42-MHz highfrequency side-looking ultrasonic transducer probe using the PNN-PZT-based ceramic with a miniature aperture of 0.33 mm × 0.33 mm was designed and fabricated, which exhibited a wide-6 dB bandwidth of 79% and an insertion loss of -19.6 dB. High spatial resolution, including the axial resolution of 36 μm and lateral resolution of 141 μm, was determined by imaging a 13-μm tungsten wire phantom. Ex vivo intravascular ultrasound (IVUS) imaging of a porcine coronary artery was performed to show the imaging capability of the miniature transducer. The results demonstrated the great potential of PNN-PZT-based ceramic for high-resolution miniature transducers application.  \nIndex Terms—Intravascular ultrasound, miniature ultrasonic transducer, PNN-PZT-based ceramic, ultrahigh dielectric permittivity, wide bandwidth.  \nI. INTRODUCTION INTRAVASCULAR ultrasound (IVUS) imaging, stretching a  \ncatheter-based miniature side-looking ultrasonic transducer into the blood vessel, has been an effective diagnosis method to determine the amount of plaques in the coronary artery diseases. In a diseased artery, the intima is thickened by plaques or other tissue growth together such that the inner diameter of lumen is reduced. Besides, the fine spatial resolution is essential to estimate the thickness of a thin-cap fibroatheroma (\u003C65 μm), which is a type of vulnerable plaque and the major precursor lesion to acute coronary syndromes [1] . As the spatial imaging resolutions and penetration depth would affect the diagnostic accuracy of coronary artery diseases, the development of miniature high-frequency transducers with broad bandwidth and high resolution is critical for IVUS application.  \nAs a tomographic imaging technique, IVUS can provide an accurate assessment of lumen size, plaque characteristics and  \nManuscript submitted xxxx, xxxx; accepted xxxx, xxxx. Date of publication xxxx, xxxx; date of current version xxxx, xxxx. This work was financially supported by the Hong Kong Polytechnic University (Grant Nos. G-YBLM, GYBPN) and the Hong Kong Research Grants Council (ECS Grant No. 253001/14P) .  \nQi Zhang and Kwok Ho Lam* are with Department of Electrical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China ([e-mail: kokokh.lam@polyu.edu.hk](e-mail: kokokh.lam@polyu.edu.hk)).  \nlesion severity [2-5] . Typically, a miniature needle singleelement transducer with the center frequency from 20 MHz to 45 MHz was operated and driven by a rotational shaft to visualize the internal cross-sectional structure of coronary artery, providing the axial resolution of 70 to 200 μm and the lateral resolution of 200 to 400 μm [6]. Nevertheless, according to the aforementioned cases, miniature ultrasonic transducers that can offer much better spatial resolutions are highly desired, which can be done by further increasing the transducer frequency and improving the bandwidth performance.  \nTo achie","cbCaimPLgwCEbwct","https://ap.wps.com/l/cbCaimPLgwCEbwct","pdf",827074,14,"English","# Introduction\n## Background and need for high-resolution IVUS\n# Abstract\n## Development approach and key performance results","[{\"question\":\"What material is used to build the miniature ultrasonic transducer?\",\"answer\":\"The transducer is based on a PNN-PZT-based ceramic, specifically Pb(Ni1/3Nb2/3)O3-Pb(Zr0.3Ti0.7)O3, designed for high-frequency intravascular imaging.\"},{\"question\":\"What are the main electrical and bandwidth performance metrics reported?\",\"answer\":\"The ceramic exhibits ultrahigh relative clamped dielectric permittivity (ƐS/Ɛ0 = 3409) and electromechanical coupling kt = 0.60. The fabricated 42-MHz probe achieves 79% wide-6 dB bandwidth and -19.6 dB insertion loss.\"},{\"question\":\"How is imaging resolution evaluated and what imaging test is performed?\",\"answer\":\"Resolution is measured using a 13-μm tungsten wire phantom, yielding 36 μm axial resolution and 141 μm lateral resolution. Ex vivo IVUS imaging of a porcine coronary artery demonstrates the miniature transducer’s imaging capability.\"}]","Miniature Transducer Using PNN-PZT-based Ceramic for Intravascular Ultrasound | PDF",1791321181,35,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/0eba0d858734cbc6b83616abaa8bbd9c.webp",983,1272,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ef67148cb214496a1f18ea845ece193b.webp",982,1270,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c471fd2ff7043284304ff6a1e7983164.webp",981,1269,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/7a8d8aa3aa3dd60f90babe9b348a679d.webp",980,1268]