[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646605-105":59,"doc-detail-646605-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","milton-roy-metering-pump-a-b-iom-manual-54649-rev07","MILTON ROY - Metering Pump A & B - IOM Manual 54649 - Rev.07","","General precautions for MILTON ROY metering pumps covering protective clothing, hearing protection thresholds, electrical safety steps, liquid/material compatibility checks, and flushing guidance for pumps primed with water. It details safe plumbing and electrical connections, line depressurization before maintenance, and over-pressure protection recommendations. Lifting and servicing requirements emphasize preventing accidental startup, attaching switch notices, proper waste oil collection and spill cleanup, and correct storage of oil/degreasing agents to comply with pollution rules.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/milton-roy-metering-pump-a-b-iom-manual-54649-rev07/646605/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/milton-roy-metering-pump-a-b-iom-manual-54649-rev07/646605.png","ImageObject",300,407,{"name":92,"@type":93},"Finn","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-01","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What PPE should be worn when working near a metering pump?","Question",{"text":112,"@type":113},"Wear protective clothing, face shield, safety glasses, and gloves when working on or near the metering pump.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What electrical safety steps are required during pump work?",{"text":117,"@type":113},"Remove power and ensure it remains off while maintaining the pump, connect the pump to earth, and match motor electrical protection to the rated current on the motor data plate.",{"name":119,"@type":110,"acceptedAnswer":120},"How should lines be handled before disassembly or maintenance?",{"text":121,"@type":113},"Depressurize the suction and discharge lines before servicing to reduce the risk of chemical contact.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646605,1792883380,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":4},34359740700684,"https://ap-avatar.wpscdn.com/avatar/1f400023980c374ae676?_k=1777273430885731487","# MILTON ROY\n\nmROY®A &B  \nMetering Pump IOM ManualManual No :54649Rev.:07Rev.Date :2/2025  \nMILTON ROY  \n## GENERAL PRECAUTIONS FOR ALL PUMPS\n\nThe following precautions should be taken when working with metering pumps.Please read thissection carefully prior to installation.  \n## Protective Clothinq\n\nALWAYS wear protective clothing,face shield,safety glasses and gloves when working on or near yourmetering pump.Additional precautions should be taken depending on the solution being pumped.Refer to Material Safety Data Sheets for the solution being pumped.  \n## Hearing Protection\n\nIt is recommended that hearing protection be used f the pump is in an environment where thetimeweighted average sound level(TWA)of 85 decibels is exceeded.(as measured on the A scaleslow response).  \n## Electrical Safety\n\n·Remove power and ensure that it remains off while maintaining pump.  \n·DO NOT FORGET TO CONNECT THE PUMP TO EARTH.  \n·Electric protection of the motor(Thermal protection or by means of fuses)is to correspond to the ratedcurrent indicated on the motor data plate.  \n## Liquid Compatibility\n\nVerify if the materials of construction of the wetted components of your pump are recommended forthe solution (chemical)to be pumped.  \n## Pumps Water“Primed”\n\nAllpumps are tested with water at the factory.If your process solution is not compatible with water,  flush the Pump Head Assembly with an appropriate solution before introducing the process solution.  \n## Plumbing and Electrical Connections\n\nAlways adhere to your local plumbing and electrical codes.  \n## Line Depressurization\n\nTo reduce the risk of chemical contact during disassembly or maintenance,the suction and dischargelines should be depressurized before servicing.  \n## Over Pressure Protection\n\nTo ensure safe operation of the system,it is recommended that some type of safety /pressure reliefvalve be installed to protect the piping and other system components from damage due to over-pressure.  \n## Lifting\n\nThis manual should be used as a guide only-Follow your company's recommended lifting procedures.It is not intended to replace or take precedence over recommendations,policies and proceduresjudged as safer due to the local environment than what is contained herein.Use lifting equipment thatis rated for the weight of the equipment 'to be lifted.  \nThe personnel responsible for installing,operating and maintaining this equipment must becomeacquainted with,assimilate and comply with the contents of this manual in order to:  \n·Avoid any possible risk to themselves or to third parties,  \n·Ensure the reliability of the equipment,  \n·Avoid any error or pollution due to incorrect operation.  \nAny servicing on this equipment must be carried out when it is stopped.Any accidental startup mustbe prevented (either by locking the switch or removing the fuse on the power supply line).  \nA notice must be attached to the location of the switch to warn that servicing is being carried out onthe equipment.  \nDuring oil changing operations,the waste oil must be collected in a suitable receptacle.Any overflowof oil which may result must be removed using a degreasing agent suitabie for the operatingconditions.  \nSoiled cleaning cloths must be stored in suitable receptacles.The oil,degreasing agent and cleaningcloths must be stored in accordance with the rules on pollution.  \nSwitch off the power supply as soon as any fault is detected during operation,such as overheatingor unusual noise.  \nSpecial care has to be taken for chemicals used in the process (acids,bases,oxidizing/reducingsolutions,etc.).  \nTABLE OF CONTENTS  \n1.0 GENERAL DESCRIPTION…………………………………………………………………………………………………………………………………7  \n1.1 INTRODUCTION……………………………………………………………………………………………………………………………………………………7  \n1.2 GENERAL INFORMATION…………………………………………………………………………………………………………………………………7  \n1.3 PUMP CHARACTERISTICS………………………………………………………………………………………………………………………………7  \n1.4 PUMP PERFORMANCE…………………………………………………………………………………………………………………………………………7  \n1.5 PRINCIPLE OF ","cbCaikWSD8bg7ZFu","https://ap.wps.com/l/cbCaikWSD8bg7ZFu","pdf",17771389,78,"English","# GENERAL PRECAUTIONS FOR ALL PUMPS\n## Protective Clothing\n## Hearing Protection\n## Electrical Safety\n## Liquid Compatibility\n## Pumps Water“Primed”\n## Plumbing and Electrical Connections\n## Line Depressurization\n## Over Pressure Protection\n## Lifting\n# TABLE OF CONTENTS\n## 1.0 GENERAL DESCRIPTION\n## 2.0 INSTALLATION\n## 3.0 OPERATION\n## 4.0 MAINTENANCE","[{\"question\":\"What PPE should be worn when working near a metering pump?\",\"answer\":\"Wear protective clothing, face shield, safety glasses, and gloves when working on or near the metering pump.\"},{\"question\":\"What electrical safety steps are required during pump work?\",\"answer\":\"Remove power and ensure it remains off while maintaining the pump, connect the pump to earth, and match motor electrical protection to the rated current on the motor data plate.\"},{\"question\":\"How should lines be handled before disassembly or maintenance?\",\"answer\":\"Depressurize the suction and discharge lines before servicing to reduce the risk of chemical contact.\"}]","MILTON ROY - Metering Pump A & B - IOM Manual 54649 - Rev.07 | PDF",1792764636,197]