[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-676022-105":59,"doc-detail-676022-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","miller-400d-digital-resistance-meter-users-manual","MILLER 400D Digital Resistance Meter - User’s Manual","","MILLER 400D Digital Resistance Meter user’s manual explains how to measure earth resistance with appropriate electrodes and test leads. It describes the meter’s automatic resistance reading without dial adjustments, and how Bluetooth-enabled computers can acquire readings through the built-in interface. The manual covers manual resistance measurement using the read button, supported electrode configurations (4-electrode, 3-electrode, 2-electrode), and applications such as earth resistivity, soil/liquid resistivity, buried electrode resistance, and electrode-to-electrode resistance. It also provides key specifications, status and error codes, maintenance and calibration, configuration settings, supporting ProCP software guidance, accuracy factors, and FCC compliance information.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/miller-400d-digital-resistance-meter-users-manual/676022/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/miller-400d-digital-resistance-meter-users-manual/676022.png","ImageObject",300,407,{"name":92,"@type":93},"lugxt","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"How does the MILLER 400D measure earth resistance?","Question",{"text":111,"@type":112},"With appropriate electrodes (pins) and test leads connected, the meter provides a direct resistance reading using a push-button operation. It automatically provides the resistance value without requiring range selection or dial adjustment.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"How do you take a manual resistance reading?",{"text":116,"@type":112},"Connect the electrodes and test leads as described in the Applications section, then press the Read button once momentarily (less than 2 seconds). The LCD Ω symbol flashes while the reading is performed, and the value is shown when complete.",{"name":118,"@type":109,"acceptedAnswer":119},"What measurement applications are supported by electrode configurations?",{"text":120,"@type":112},"The manual states that 4-electrode, 3-electrode, and 2-electrode applications can determine average earth resistivity to a depth, resistivity of soil or liquids via an electrolyte box, resistance-to-earth of buried electrodes (e.g., ground rod or anode), and resistance between two buried electrodes (e.g., two ground rods or two anodes).","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},676022,1793774652,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":128,"read_time":143},3985747862600,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","MILLER 400D  \nDIGITAL RESISTANCE METER  \nUSER’S MANUAL  \nRevised May 19, 2014  \n11640 US Hwy 1 Sebastian, FL 32958 Tel: 1.772.794.9448 ~ Fax: 1.772.589.9072  \nE-mail: [sales@mcmiller.com](sales@mcmiller.com) ~ [Web Site:](Web Site: www.mcmiller.com)[ ](Web Site: www.mcmiller.com)[www.mcmiller.com](Web Site: www.mcmiller.com)  \nInstruments and Software for the Corrosion Engineer  \nCONTENTS  \nPage  \nSection 1: Description ……………………………………………… 3  \nSection 2: How to Take Resistance Readings Manually …………… 4  \nSection 3: Logging Resistance Readings on a Bluetooth-Enabled Computer (PDA, Laptop etc.)………………………….. 5  \nSection 4: Applications ……………………………………………... 6  \n4-Electrode Applications .……………………………………. 6  \nEarth Resistivity Measurement ………………………... 6  \nSoil Sample Resistivity Measurement …………………. 8  \n3-Electrode Application ………………………………………. 10  \n2-Electrode Application ………………………………………. 13  \nSection 5: Status Indicators and Error Codes ………………………. 15  \nSection 6: Maintenance & Calibration ……………………………... 17  \nAppendix 1: How to Change Settings (from their default values) Using the Miller 400D Configuration Program ………. 18  \nAppendix 2: How to use the ProCP Soil Resistivity Survey Program in conjunction with the Miller 400D …….…. 23  \nAppendix 3: Influence of test lead proximity on the accuracy of AC resistance meter readings ……………………… 38  \nAppendix 4: Specifications…………………………………………... 39  \nFCC Statement:  \nThe Miller 400D Resistance Meter meets current FCC radio frequency exposure guidelines and complies with Part 15 of the FCC Rules.  \nFCC Equipment Authorization ID: POOWML-C40  \n11640 US Hwy 1 Sebastian, FL 32958 Tel: 1.772.794.9448 ~ Fax: 1.772.589.9072  \nE-mail: [sales@mcmiller.com](sales@mcmiller.com) ~ [Web Site:](Web Site: www.mcmiller.com)[ ](Web Site: www.mcmiller.com)[www.mcmiller.com](Web Site: www.mcmiller.com)  \nInstruments and Software for the Corrosion Engineer  \nSECTION 1: DESCRIPTION  \nWhen combined with appropriate electrodes (pins) and test leads, the MILLER-400D can be used to measure earth resistance with the push of a button.  \nThere is no need to adjust dials or select ranges; the MILLER-400D automatically provides a direct resistance reading.  \nIn addition to taking (and recording) readings manually (see Section 2), a Bluetooth-enabled computer (PDA, laptop etc.) can be programmed to acquire resistance readings directly from the Miller 400D, since the resistance meter has a built-in Bluetooth interface (see Section 3) . In the latter case, the PDA or PC, which is in control of the Bluetooth link, commands the Miller 400D to take a reading and the resistance value is sent automatically to the PDA or PC.  \nDepending on the application, 4-Electrode, 3-Electrode or 2-Electrode, the MILLER-400D can be used to determine the following:  \n• The average earth resistivity to a specific depth (with the application of an appropriate multiplier to convert resistance to resistivity, based on the electrode separation distance)– 4-Electrode Application  \n• The resistivity of a soil sample, or of a liquid, via an electrolyte (soil/liquid) box (with the application of an appropriate multiplier to convert resistance to resistivity, depending on the box geometry)– 4-Electrode Application  \n• The resistance-to-earth of a buried electrode, such as a ground rod, or an anode, for example – 3-Electrode Application  \n• The resistance between two buried electrodes, such as two ground rods, or two anodes – 2-Electrode Application  \nThe MILLER-400D has a resistance measurement range (with automatic ranging) from 0.01Ω to 10MΩ . Over the range, 0.01Ω to 1MΩ, the specified meter accuracy is ±1.6% ±1 LS display digit ±0.01Ω and over the range, 1MΩ to 10MΩ, the specified accuracy is ±5% ±1 LS display digit. Note:  \nFor load resistances >1MΩ, in addition to internal meter errors, errors  \n11640 US Hwy 1 Sebastian, FL 32958 Tel: 1.772.794.9448 ~ Fax: 1.772.589.9072  \nE-mail: [sales@mcmiller.com](sales@mcmiller.com) ~ [Web Site:](Web Site: www.mcm","cbCaiuFC7hFvoQXU","https://ap.wps.com/l/cbCaiuFC7hFvoQXU","pdf",1497107,39,"English","# Section 1: Description\n# Section 2: How to Take Resistance Readings Manually\n# Section 3: Logging Resistance Readings on a Bluetooth-Enabled Computer (PDA, Laptop etc.)\n# Section 4: Applications\n## 4-Electrode Applications\n## Earth Resistivity Measurement\n## Soil Sample Resistivity Measurement\n## 3-Electrode Application\n## 2-Electrode Application\n# Section 5: Status Indicators and Error Codes\n# Section 6: Maintenance & Calibration\n# Appendix 1: How to Change Settings (from their default values) Using the Miller 400D Configuration Program\n# Appendix 2: How to use the ProCP Soil Resistivity Survey Program in conjunction with the Miller 400D\n# Appendix 3: Influence of test lead proximity on the accuracy of AC resistance meter readings\n# Appendix 4: Specifications","[{\"question\":\"How does the MILLER 400D measure earth resistance?\",\"answer\":\"With appropriate electrodes (pins) and test leads connected, the meter provides a direct resistance reading using a push-button operation. It automatically provides the resistance value without requiring range selection or dial adjustment.\"},{\"question\":\"How do you take a manual resistance reading?\",\"answer\":\"Connect the electrodes and test leads as described in the Applications section, then press the Read button once momentarily (less than 2 seconds). The LCD Ω symbol flashes while the reading is performed, and the value is shown when complete.\"},{\"question\":\"What measurement applications are supported by electrode configurations?\",\"answer\":\"The manual states that 4-electrode, 3-electrode, and 2-electrode applications can determine average earth resistivity to a depth, resistivity of soil or liquids via an electrolyte box, resistance-to-earth of buried electrodes (e.g., ground rod or anode), and resistance between two buried electrodes (e.g., two ground rods or two anodes).\"}]","MILLER 400D Digital Resistance Meter - User’s Manual | PDF",98]