[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-652610-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-652610-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","mettler-toledo-ph-transmitter-2100-e2xh-instruction-manual","Mettler Toledo pH Transmitter 2100 e/2(X)H - Instruction Manual","","Instruction manual for the METTLER TOLEDO pH Transmitter 2100 e/2(X)H, providing guidance for safe commissioning, installation, wiring, configuration, operation, calibration, diagnostics, and disposal. Covers safety information and intended use, EC conformity and FDA 21 CFR Part 11 related requirements, assembly and mounting options, terminal assignments and wiring examples for pH and ORP, user interface controls, alarm and passcode settings, calibration modes including Calimatic and manual procedures, as well as error messages, Sensoface monitoring, specifications, buffer tables, drawings, glossary, and index.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/mettler-toledo-ph-transmitter-2100-e2xh-instruction-manual/652610/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/mettler-toledo-ph-transmitter-2100-e2xh-instruction-manual/652610.png","ImageObject",300,407,{"name":42,"@type":43},"Rainbow Cat","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",6,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"Who may carry out commissioning and what safety checks are required before recommissioning?","Question",{"text":63,"@type":64},"Commissioning may only be carried out by trained experts. If protection may be impaired, the device must be made inoperative and secured, and a professional routine test in accordance with EN 61010-1 must be performed before recommissioning.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What topics are covered for installation and electrical connection of the pH transmitter?",{"text":68,"@type":64},"The manual includes assembly and mounting plans, installation and connection information, Division 2 wiring, terminal assignments, and wiring examples for pH and ORP.",{"name":70,"@type":61,"acceptedAnswer":71},"How does the manual describe calibration and calibration-related diagnostics?",{"text":72,"@type":64},"It covers calibration modes, pH and ORP calibration procedures (including automatic calibration with Calimatic and manual calibration), zero point adjustment, temperature probe adjustment, and diagnostics such as operating states, error messages (error codes), calibration error messages, and Sensoface monitoring.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},652610,1793030005,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145},962090769181,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Mettler Toledo pH 2100/2H Transmitter  \n$ 195.00  \nIn Stock  \nQty Available: 10+  \nUsed and in Excellent Condition  \nOpen Web Page  \n[https://www.artisantg.com/77039-3](https://www.artisantg.com/77039-3)  \nArtisan Scientific Corporation dba Artisan Technology Group is not an affiliate, representative, or authorized distributor for any manufacturer listed herein.  \nInstruction manual pH Transmitter 2100 e/2(X)H  \n70090  \nScientific-Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | [www.artisan-sci](www.artisan-sci)e  \nWarranty  \nDefects occurring within 1 year from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender) .  \nSubject to change without notice.  \nReturn of products under warranty  \nPlease contact METTLER TOLEDO’s Customer Service Dept. before returning a defective device. Ship the cleaned device to the address you have been given. If the device has been in contact with process fluids, it must bedecontaminated/disinfected before shipment. In that case, please attach a corresponding certificate, for the health and safety of our service personnel.  \nDisposal (Directive 2002/96/EC of January 27, 2003) Please observe the applicable local or national regulations concerning the disposal of “waste electrical and electronic equipment”.  \nMettler-Toledo GmbH, Process Analytics, Industrie Nord, CH-8902 Urdorf, Tel. +41 (01) 736 22 11 Fax +41 (01) 736 26 36 Subject to technical changes. Mettler-Toledo GmbH, 09/03 .  \nPrinted in Germany.  \nScientific-Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | [www.artisan-sci](www.artisan-sci)e  \nContents  \nSafety information ......................... 5  \nIntended use ..................................7  \nTrademarks ...................................7  \nEC Declaration of Conformity................. 8  \nConformity with FDA 21 CFR Part 11 ........... 9  \nEC-Type-Examination Certificate.............. 10  \nOverview of pH Transmitter 2100 e /2XH ....... 15  \nAssembly................................. 16  \nPackage contents ............................. 16  \nMounting plan ............................... 17  \nPipe mounting, panel mounting ..................18  \nInstallation and connection ................. 20  \nInformation on installation ...................20, 22  \nDivision 2 wiring ..............................20    \nTerminal assignments ...........................21  \nWiring examples pH ...........................24  \nWiring example ORP ...........................29  \nUser interface and display .................. 30  \nOperation: Keypad ......................... 32  \nSafety functions ........................... 33  \nSensocheck, Sensoface sensor monitoring ...........33  \nGainCheck device self test .......................33  \nAutomatic device self-test .......................33  \nHold mode ..................................34  \nOutputs .................................. 35  \n(Loop current, HART communication, Alarm)  \nPasscodes ................................ 37  \nConfiguration ............................. 38  \nMenu structure of configuration ..................39  \n3  \nScientific-Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | [www.artisan-sci](www.artisan-sci)e  \nOverview of configuration steps ..................40  \nCurrent output ...............................42  \nTemperature compensation ......................50  \nCalibration mode .............................54  \nAlarm settings ................................56  \nPasscodes according to FDA 21 CFR Part 11 .... 58  \nCalibration ............................... 60  \npH calibration ................................61  \nZero point adjustment ..........................62  \nAutomatic calibration with Calimatic ...............64  \nManual calibration ............................66  \nData entry of premeasured electrodes ..............68  \nProduct calibration ............................70  \nORP calibration ...............................72  \n Temp probe adjustment ..........","cbCaifyyUXNBoNcj","https://ap.wps.com/l/cbCaifyyUXNBoNcj","pdf",4257511,118,"English","# Safety information\n# Intended use\n# Trademarks\n# EC Declaration of Conformity\n# Conformity with FDA 21 CFR Part 11\n# EC-Type-Examination Certificate\n# Overview of pH Transmitter 2100 e /2XH\n## Assembly\n## Package contents\n## Mounting plan\n## Pipe mounting, panel mounting\n# Installation and connection\n## Information on installation\n## Division 2 wiring\n## Terminal assignments\n## Wiring examples pH\n## Wiring example ORP\n# User interface and display\n## Operation: Keypad\n## Safety functions\n## Sensocheck, Sensoface sensor monitoring\n## GainCheck device self test\n## Automatic device self-test\n## Hold mode\n# Outputs\n## Passcodes\n# Configuration\n## Menu structure of configuration\n## Overview of configuration steps\n## Current output\n## Temperature compensation\n## Calibration mode\n## Alarm settings\n## Passcodes according to FDA 21 CFR Part 11\n# Calibration\n## pH calibration\n## Zero point adjustment\n## Automatic calibration with Calimatic\n## Manual calibration\n## Data entry of premeasured electrodes\n## Product calibration\n## ORP calibration\n## Temp probe adjustment\n# Measurement\n## Diagnostics functions\n## Operating states\n## Error messages (error codes)\n## Calibration error messages\n## Sensoface\n# Appendix\n## Product line and accessories\n## Specifications\n## Buffer tables\n## Control / Installation Drawings\n## Glossary\n## Index","[{\"question\":\"Who may carry out commissioning and what safety checks are required before recommissioning?\",\"answer\":\"Commissioning may only be carried out by trained experts. If protection may be impaired, the device must be made inoperative and secured, and a professional routine test in accordance with EN 61010-1 must be performed before recommissioning.\"},{\"question\":\"What topics are covered for installation and electrical connection of the pH transmitter?\",\"answer\":\"The manual includes assembly and mounting plans, installation and connection information, Division 2 wiring, terminal assignments, and wiring examples for pH and ORP.\"},{\"question\":\"How does the manual describe calibration and calibration-related diagnostics?\",\"answer\":\"It covers calibration modes, pH and ORP calibration procedures (including automatic calibration with Calimatic and manual calibration), zero point adjustment, temperature probe adjustment, and diagnostics such as operating states, error messages (error codes), calibration error messages, and Sensoface monitoring.\"}]","Mettler Toledo pH Transmitter 2100 e/2(X)H - Instruction Manual | PDF",1792881349,297]