[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-652617-105":59,"doc-detail-652617-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","mettler-toledo-calibration-instructions-impulse-systems-quick-start-guide","Mettler Toledo Calibration Instructions - imPULSE Systems Quick Start Guide","","Quick Start Guide for calibration of Mettler Toledo IND331 and IND560 models used on Thermo Scientific imPULSE Single-Use Mixers (S.U. M.s). The guide describes control key functions and step-by-step procedures to run Set Zero and CalFREE calibration, including prompts, menu navigation, and expected display confirmations such as “Capture Zero Ok” and “CALIBRATION OK.” It also notes safety and operational guidance to consult the imPULSE S.U. M. User’s Guide.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/mettler-toledo-calibration-instructions-impulse-systems-quick-start-guide/652617/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/mettler-toledo-calibration-instructions-impulse-systems-quick-start-guide/652617.png","ImageObject",300,407,{"name":92,"@type":93},"WPS_1790064749","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of this Quick Start Guide?","Question",{"text":112,"@type":113},"It provides a brief overview of calibration procedures for the Mettler Toledo IND331 and IND560 models used on Thermo Scientific imPULSE Single-Use Mixers (S.U. M.s).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How do you begin IND331 calibration?",{"text":117,"@type":113},"Press and hold the Print key for three seconds to access information recall, then use the Clear and Print keys to enter the Setup Mode and navigate to Set Zero.",{"name":119,"@type":110,"acceptedAnswer":120},"What display messages should be expected during calibration?",{"text":121,"@type":113},"During IND331 calibration it indicates “Capture Zero Ok” after Set Zero, and later shows “CALIBRATION OK.” During IND560 calibration it shows “Capture Zero Ok,” followed by “Calibration OK.”","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},652617,1793128735,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":19,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":52},3985747859154,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Mettler Toledo Calibration Instructions (For imPULSE Systems) Quick Start Guide  \nThis guide provides a brief overview of calibration for the Mettler Toledo™ IND331 and IND560 models used on the Thermo Scientific™ imPULSE™ Single-Use Mixers (S.U. M.s) . Please take the time to review the imPULSE S.U. M. User’s Guide (DOC0043) for important information on safety and operation.  \nMettler Toledo IND331 Calibration steps  \nIND331 control descriptions and navigations:  \nFigure 1 includes a description of the scale function keys. In the Setup Menu, the scale function keys are used for navigation as described in Figure 2.  \nTare  \nWeight display  \nZero  \nPrint  \nClear  \nFigure 1. Functions of the scale function keys in the Setup Menu.  \nFigure 2. Description of navigation using the scale function keys.  \nProcess steps  \n1. Press and hold the Print key (see Figure 1) for three seconds. The display will change from showing a normal weight to the information recall icon:  .  \n2. Press the Clear key (Figure 1) until the Setup icon appears  , then press the Print key to enter the Setup Mode. Note: This gives access to all setup parameters for the terminal.  \n3. Use the scale function keys to navigate (see Figure 2) to Set Zero in the setup menu. See Figure 3 for the path in the menu tree.  \nFigure 3. Location of Set Zero in the Setup Menu.  \n4. Follow the prompts and remove all weight. Press Print. The display will indicate “Capture Zero Ok”.  \n5. After Set Zero is completed, press the Print key. Use the scale function keys to navigate through the calibration menu again to select CalFREE (Figure 4) and press Print.  \nFigure 4. Location of CalFREE in the Setup Menu.  \n6. After selecting CalFREE , follow the prompts and either input the full scale weight (using the navigation keys), or accept the current value and press the Print key.  \n7. Press the Print key again to accept the rated cell output. The display will indicate “Perform CalFREE?”  \n8. Press Print, and after cycling through the percentage completed, the display will read: “CALIBRATION OK.”  \n9. Press Print to return to the scale menu.  \n10. Press the Zero key twice to exit the Setup Menu and then press the Tare key until you return the the weight indication display.  \n2  \nMettler Toledo IND560 Calibration steps  \nIND560 control descriptions and navigations:  \nFigure 5 includes a description of the scale function keys. Use the Up and Down navigation (nav.) keys to navigate the menu tree. Use the Right nav. key to expand a branch, and the Left nav. key to collapse a branch.  \nNumeric keys  \nFigure 5. IND560 control descriptions.  \nProcess steps  \n1. Press the Down nav. key (Figure 5) to view the Setup Menu softkey label  .  \n2. Press the Setup Menu  softkey (Figure 6) .  \nFigure 6. Softkey that corresponds with Setup Menu icon.  \n3. Navigate to Calibration (Figure 7) .  \n4. Once the desired menu option is highlighted, press the Enter key (center nav. key) .  \nFigure 7. Location of Calibration in the Setup Menu.  \n5. The calibration menu has multiple pages similar to those shown in Figures 8 and 9. Press the Down nav. key to navigate through the calibration menu pages until the Softkey Calibration Labels are visible.  \nFigure 8. Softkey Calibration Labels not visible on page 1.  \nFigure 9. Softkey Calibration Labels visible on page 3.  \n6. Press the Capture Zero  softkey.  \nFigure 10. Softkey that corresponds with the Capture Zero icon.  \n7. Remove any weights and follow the prompts. Press the Start  softkey (Figure 11) . The screen will read“Capture Zero Ok.”  \nFigure 11. Softkey that corresponds with the Start icon.  \n8. After Set Zero is comple, press the Exit  softkey (Figure 12) to exit the current menu.  \nFigure 12. Softkey that corresponds with the Exit icon.  \n9. Press the softkey that corresponds with the CalFREE softkey label (Figure 13) .  \nFigure 13. Softkey that corresponds with the CalFREE icon.  \n10. Press the Down nav. key to navigate through the CalFREE menu pages u","cbCaiewexrVKBBnH","https://ap.wps.com/l/cbCaiewexrVKBBnH","pdf",495885,"English","# Calibration instructions overview\n# IND331 calibration steps\n## Control keys and navigation\n## Process steps: Set Zero and CalFREE\n# IND560 calibration steps\n## Control keys and navigation\n## Process steps: Capture Zero and CalFREE","[{\"question\":\"What is the purpose of this Quick Start Guide?\",\"answer\":\"It provides a brief overview of calibration procedures for the Mettler Toledo IND331 and IND560 models used on Thermo Scientific imPULSE Single-Use Mixers (S.U. M.s).\"},{\"question\":\"How do you begin IND331 calibration?\",\"answer\":\"Press and hold the Print key for three seconds to access information recall, then use the Clear and Print keys to enter the Setup Mode and navigate to Set Zero.\"},{\"question\":\"What display messages should be expected during calibration?\",\"answer\":\"During IND331 calibration it indicates “Capture Zero Ok” after Set Zero, and later shows “CALIBRATION OK.” During IND560 calibration it shows “Capture Zero Ok,” followed by “Calibration OK.”\"}]","Mettler Toledo Calibration Instructions - imPULSE Systems Quick Start Guide | PDF",1792881365]