[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-652611-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-652611-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","mettler-toledo-ampm-balances-operating-instructions","METTLER TOLEDO AM/PM Balances - Operating Instructions","","Operating instructions for METTLER TOLEDO precision and analytical balances in the AM and PM series (up to a 6 kg weighing range). Covers choosing a suitable installation location, mounting the weighing pan/platform, leveling, and installing the draft shield. Details control elements, display indicators (including METTLER DeltaTrac/DeltaRange), switching the display, basic weighing and taring, menu navigation, calibration, adapting to weighing process and vibration conditions, configuration and configuration protection, applications (unit switching, piece counting, plus/minus and percent weighing, animal weighing, print/transfer), and troubleshooting faults, plus maintenance items such as voltage and fuse replacement.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/mettler-toledo-ampm-balances-operating-instructions/652611/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/mettler-toledo-ampm-balances-operating-instructions/652611.png","ImageObject",300,407,{"name":42,"@type":43},"pop out","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-28","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":30},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What installation location is recommended for best weighing results?","Question",{"text":62,"@type":63},"Use a firm, vibration-free location as horizontal as possible. Avoid direct sunlight, extreme temperature changes, and drafts.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"How should the draft shield be installed and aligned?",{"text":67,"@type":63},"Install the recommended draft shield to prevent draft influence on sensitive ranges. Ensure it is properly engaged and aligned parallel to the balance.",{"name":69,"@type":60,"acceptedAnswer":70},"Which procedures are covered for calibration and adapting the balance?",{"text":71,"@type":63},"The instructions include calibrating, adapting to the type of weighing using the weighing process adapter, and adapting to ambient conditions using the vibration adapter.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},652611,1793051756,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":30,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145},962090760408,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","Operating instructions  \nMETTLER TOLEDO AM/PM Balances  \nThank you very much for the confidence you have shown in our products by choosing a METTLER TOLEDO precision or analytical balance. To obtain complete satisfaction from your balance, it is essential that you read through these operating instructions carefully.  \nThese operating instructions apply to balances of the AM and PM series with a weighing range up to 6 kg. Although the operating procedures for these balances are identical, differences exist regarding the weighing range, the readability accuracy and the weighing pan or platform. Enclosed with these operating instructions is the booklet «Technical data and accessories», which also contains possibilities of the METTLER TOLEDO AM/PM balances.  \nPage  \nPreparation Choosing the location 4  \nMounting the weighing pan / levelling the balance 5  \nInstalling the draft shield 6  \nOperation Control elements / connections / display 8  \nMETTLER DeltaTrac / METTLER DeltaRange 9  \nSwitching display on and off 10  \nSimple weighing / taring 11  \nSingle-key (control bar) operation 12  \nMenu Overview 14  \nCalibrating 15  \nAdapting to the type of weighing (weighing process adapter) 16  \nAdapting to the ambient conditions (vibration adapter) 17  \nConfiguring Overview 18  \nConfiguration example 20  \nStandard settings and record printout 22  \nBalance operating settings 24  \nUnit selection, applications, print / transfer command, status display 26  \nAdapting to external equipment 28  \nProtecting the configuration 30  \nApplications Overview 32  \nSwitching the weight unit 33  \nPiece counting 34  \nPlus / minus and percent weighing 36  \nAnimal weighing 38  \nPrint / transfer command 39  \nWhat if... Fault rectification 40  \nMiscellaneous Changing the operating voltage / replacing the fuse 42  \nChanging the protective cover / maintenance 43  \nTechnicals terms 44  \nTechnical data Overview 45  \nPreparation 4  \nSelect the proper location  \nFor best results choose a suitable location for your balance.  \nA firm, vibration-free location as horizontal as possible Avoid exposure to direct sunlight  \nNo extreme temperature changes  \nNo draft  \nDespite a possible unfavorable location, your balance can still produce accurate weighing results:  \nIn this case you should adjust the vibration adapter accordingly. For procedures refer to section «Menu» .  \nMount the weighing pan / platform  \n10   \n11   \n17   \n20  \n| 10\u003Cbr>11\u003Cbr>40 | | 20 |\n| --- | --- | --- |\n\nPM balances with weighing pan Place pan support 11 and weighing pan 10 on tapered pin 17 ; connect power cable 20.  \nPM balances with weighing platform Install platform support 11 with the four pins resting on the four rubber grommets 40 ; then position weighing platform 10 on platform support 11 ; connect power cable 20.  \nAM balances: see page 7.  \n…and now, level the balance  \n\n| 8 \u003Cbr>\u003Cbr>9\u003Cbr>~~ ~~ 8\u003Cbr>| |  |\n| --- | --- | --- |\n|  | | |\n\nAfter each relocation of the balance, repeat levelling procedures. For this purpose adjust bubble in level indicator 9 with the two levelling screws 8.  \nPreparation 5  \nPreparation 6  \nDon't forget to install the draft shield  \nTo ensure that the weighing results are not influenced by the drafts (particularly for sensitive measuring ranges) we recommend the installation of a draft shield.  \nPM balances with 1 mg readability  \nMounting procedures 1 and 2 are needed only if the bottom element 12 has not been installed at the factory.  \nRemove weighing pan 10 and pan support 11.  \nPlace bottom element 12 on balance, and rotate to stop. Replace pan support 11 and weighing pan 10.  \nMount draft shield 13 and engage.  \n2  \n3  \nAM balances  \nMount glass draft shield 13 on scale rotated by 45° . Note that tapered pin 17 must be visible through bottom hole 27. Now rotate glass draft shield clockwise to stop.  \nVerify that the draft shield is aligned parallel to the balance and is properly engaged in bayonet base.  \nInstall ring 25 and weighing pan 10 , close sliding door","cbCaiqHW5BLcRWnb","https://ap.wps.com/l/cbCaiqHW5BLcRWnb","pdf",914726,48,"English","# Preparation\n## Choosing the location\n## Mounting the weighing pan / levelling the balance\n## Installing the draft shield\n# Operation\n## Control elements / connections / display\n## METTLER DeltaTrac / METTLER DeltaRange\n## Switching display on and off\n## Simple weighing / taring\n## Single-key (control bar) operation\n## Menu Overview\n## Calibrating\n## Adapting to the type of weighing (weighing process adapter)\n## Adapting to the ambient conditions (vibration adapter)\n# Configuration\n## Configuration example\n## Standard settings and record printout\n## Balance operating settings\n## Unit selection, applications, print / transfer command, status display\n## Adapting to external equipment\n## Protecting the configuration\n# Applications\n## Switching the weight unit\n## Piece counting\n## Plus / minus and percent weighing\n## Animal weighing\n## Print / transfer command\n## What if... Fault rectification\n# Miscellaneous\n## Changing the operating voltage / replacing the fuse\n## Changing the protective cover / maintenance\n## Technical terms\n# Technical data","[{\"question\":\"What installation location is recommended for best weighing results?\",\"answer\":\"Use a firm, vibration-free location as horizontal as possible. Avoid direct sunlight, extreme temperature changes, and drafts.\"},{\"question\":\"How should the draft shield be installed and aligned?\",\"answer\":\"Install the recommended draft shield to prevent draft influence on sensitive ranges. Ensure it is properly engaged and aligned parallel to the balance.\"},{\"question\":\"Which procedures are covered for calibration and adapting the balance?\",\"answer\":\"The instructions include calibrating, adapting to the type of weighing using the weighing process adapter, and adapting to ambient conditions using the vibration adapter.\"}]","METTLER TOLEDO AM/PM Balances - Operating Instructions | PDF",1792881350,121]