[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664087-105":59,"doc-detail-664087-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","method-of-statement-mos-mechanical-electrical","Method of Statement (MOS) - Mechanical & Electrical","","Method of Statement (MOS) document for the LONZA BIOLOGICS TUAS PTE LTD (LBT) Road Runner Expansion Project, covering subcontract requisition for fit-out works. The scope includes installation procedures for electrical systems (cable conduits, cable trunking, cable trays, ladders, termination, switchboards and sub distribution boards) and mechanical/HVAC equipment installation (chillers, cooling towers, pumps, AHUs, heat exchangers), followed by pipework and ductwork installation. It specifies references, tools and materials, pre-preparation steps, safety precautions, and step-by-step work procedures with checklist forms.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/method-of-statement-mos-mechanical-electrical/664087/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/method-of-statement-mos-mechanical-electrical/664087.png","ImageObject",300,407,{"name":92,"@type":93},"Franzy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of this Method of Statement (MOS) document?","Question",{"text":112,"@type":113},"It defines installation methods for mechanical and electrical fit-out works, including detailed procedures for electrical components and HVAC equipment, along with pipework and ductwork installation steps.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which standards and references are cited for electrical installation work?",{"text":117,"@type":113},"The document references working drawings and Singapore Standard CP5: 1988 as the code of practice for electrical installation.",{"name":119,"@type":110,"acceptedAnswer":120},"What elements does the cable conduit installation section include?",{"text":121,"@type":113},"It covers purpose, document references, equipment/tools/materials, pre-preparation work, safety precautions, and a numbered work procedure, followed by checklist records.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664087,1793238838,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},2336478945519,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","ACROMEC Engineers Pte Ltd-Method of Statement (MOS)   \nMethod of Statement  \n(Mechanical & Electrical)  \nRevision 0  \nPrepared for:  \nLONZA BIOLOGICS TUAS PTE LTD (LBT): Road Runner Expansion ProjectSubcontract Requisition for Fit-Out  \nDecember 2016  \nACROMEC Engineers Pte Ltd-Method of Statement (MOS)   \nTable of Content  \n\n|  | Description | PAGE |\n| --- | --- | --- |\n| 1 | ELECTRICAL | 3-16 |\n|  | 1.1 Installation of cable conduit works |  |\n|  | 1.2 Installation of cable trunking works |  |\n|  | 1.3 Installation of cable tray works |  |\n|  | 1.4 Installation of cable ladder works |  |\n|  | 1.5 Installation of cable and termination works |  |\n|  | 1.6 Installation of sub distribution board works |  |\n|  | 1.7 Installation of LT Main Switchboard works |  |\n| 2 | HVAC EQUIPMENT INSTALLATION | 17-30 |\n|  | 2.1 Installation of Chiller works |  |\n|  | 2.2 Installation of cooling tower works |  |\n|  | 2.3 Installation of pump works |  |\n|  | 2.4 Installation of air handling unit (AHU) works |  |\n|  | 2.5 Installation of Heat Exchanger works |  |\n| 3 | PIPEWORK INSTALLATION | 31-35 |\n| 4 | DUCTWORK INSTALLATION | 36-44 |\n\nACROMEC Engineers Pte Ltd-Method of Statement (MOS)   \n1. ELECTRICAL  \n1.1  Installation of cable conduit works  \nPurpose  \n􀀁 To define the method of installation for Cable Conduits.  \nDocument/Drawing/Standard Reference  \n􀀁 Working Drawings.  \n􀀁 Singapore Standard CP5: 1988 (Code of practice for electrical Installation)  \nEquipment/Tools/Material Requirements  \n􀀁 Concrete Drill.  \n􀀁 Hand Tools.  \n􀀁 Hand Drills.  \n􀀁 Hacksaw.  \n􀀁 Measuring Tape.  \n􀀁 Fibre Cutter & Raw plugs.  \n􀀁 Scaffolding.  \n􀀁 Ladder.  \n􀀁 Marker Pen.  \nACROMEC Engineers Pte Ltd-Method of Statement (MOS)   \n􀀁 Conduit Bender and Dies.  \n􀀁 Conduits & Fittings.  \nPre-Preparation Work  \n􀀁 Ensure that site access and location is clear and free of debris and obstruction.  \n􀀁 Marked out all relevant positions or locations on the working drawings for the installation to proceed.  \nSafety Precautions  \n􀀁 Barricade all work areas relating to the works if required.  \n􀀁 Wear Proper Protection Equipment (PPE) for personal safety.  \n􀀁 Proper ladder should be secured by tight rope/wire, proper roller clamp on suitable hook.  \n􀀁 All electrical tools and equipment shall be properly earth.  \n􀀁 Proper scaffolding to be provided while working in the heights.  \nWork Procedures  \n1. Refer to working drawings and marked out the position of conduit saddle on the Working drawings.  \n2. Marked out the relevant positions to install the conduit saddle at the walls and ceilings.  \n3. Cut the conduit to the required length. Use the conduit Reamer or half round file to smoothen the sharp edges at both end of the conduit.  \n4. Confirm actual location of conduit. Drill the required diameter at the walls and ceilings.  \n5. Ensure all conduit saddle are provided at one metre apart.  \n6. Install conduit box by turning the conduit box in to the threaded conduit. Use monkey pliers it tightens up the conduit box.  \nACROMEC Engineers Pte Ltd-Method of Statement (MOS)   \n7. By making use of the conduit bender, fabricate 90-degree bend. Off set to meets the site condition.  \n8. Insert the raw plugs into the drilled holes of walls and ceilings.  \n9. Secure the G. I. conduit by saddle and screw nuts.  \n10. Touch up the edges, bending and scratches areas of conduit ends to touch up with 2nd layer of final coat paint.  \nForms /Checklist Records  \n􀀁 Checklist for Cable Conduits Installation.  \n1.2  Installation of cable trunking works  \nPurpose  \n􀀁 To define the method of installation for Cable Trunking.  \nDocument/Drawing/Standard Reference  \n􀀁 Working Drawings.  \n􀀁 Singapore Standard CP5: 1988 (Code of practice for electrical Installation)  \nEquipment/Tools/Material Requirements  \n􀀁 Hand Tools.  \n􀀁 Concrete Drill.  \n􀀁 Hand Drills.  \n􀀁 Hack Saws.  \n􀀁 Measuring Tapes.  \n􀀁 Fiber Cutter.  \n􀀁 Scaffolding.  \nACROMEC Engineers Pte Ltd-Method of Statement (MOS)   \n􀀁 Ladder.  \n􀀁 Marker Pen.  \n􀀁 Tru","cbCaiaDj7cuiUTDc","https://ap.wps.com/l/cbCaiaDj7cuiUTDc","pdf",274637,46,"English","# ELECTRICAL\n## Installation of cable conduit works\n## Installation of cable trunking works\n## Installation of cable tray works\n## Installation of cable ladder works\n## Installation of cable and termination works\n## Installation of sub distribution board works\n## Installation of LT Main Switchboard works\n# HVAC EQUIPMENT INSTALLATION\n## Installation of Chiller works\n## Installation of cooling tower works\n## Installation of pump works\n## Installation of air handling unit (AHU) works\n## Installation of Heat Exchanger works\n# PIPEWORK INSTALLATION\n# DUCTWORK INSTALLATION","[{\"question\":\"What is the purpose of this Method of Statement (MOS) document?\",\"answer\":\"It defines installation methods for mechanical and electrical fit-out works, including detailed procedures for electrical components and HVAC equipment, along with pipework and ductwork installation steps.\"},{\"question\":\"Which standards and references are cited for electrical installation work?\",\"answer\":\"The document references working drawings and Singapore Standard CP5: 1988 as the code of practice for electrical installation.\"},{\"question\":\"What elements does the cable conduit installation section include?\",\"answer\":\"It covers purpose, document references, equipment/tools/materials, pre-preparation work, safety precautions, and a numbered work procedure, followed by checklist records.\"}]","Method of Statement (MOS) - Mechanical & Electrical | PDF",116]