[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-665117-105":59,"doc-detail-665117-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","metal-windows-design-standards","Metal Windows - Design Standards","","Design standards for metal windows, specifying general criteria for steel window applications developed for Yale University. Covers required security screen provision, commercial-grade high-performance window types, complete hardware for operable units, and detailed performance targets including air and water infiltration limits, thermal equivalence to insulating glass, acoustical sound transmission, and maximum deflection. Also defines submission requirements for shop drawings, engineer-sealed calculations, samples, and product data, along with manufacturer qualification and material compliance.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/metal-windows-design-standards/665117/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/metal-windows-design-standards/665117.png","ImageObject",300,407,{"name":92,"@type":93},"WPS_1786070896","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the required performance criteria for metal windows?","Question",{"text":112,"@type":113},"The document specifies maximum limits for water infiltration and air infiltration at 20% of design wind pressure, thermal performance matching insulating glass units, acoustical performance with a sound transmission class of 30–32, and deflection not exceeding 1/175 of unsupported spans.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What must be submitted to Yale University before installing metal windows?",{"text":117,"@type":113},"Submittals include shop drawings showing coordinated layouts and elevations/sections/details, structural calculations sealed by a licensed professional engineer, material samples in required quantities and sizes, and manufacturers’ product data with installation/maintenance instructions and certified test reports where applicable.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the document handle quality control and warranty requirements?",{"text":121,"@type":113},"Quality control requires work to follow the AAMA Metal Curtain Wall guide specifications, maintenance of a manual on site, a single firm assuming undivided fabrication/installation responsibility with at least five years’ experience, and independent laboratory testing. Warranty requires a five-year manufacturer warranty covering system failures to meet specified requirements and glass breakage due to defined defects or installation issues for five years.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},665117,1793290533,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},549768072016,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","08500  \nMetal Windows  \nThis document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on  \ndrawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager.  \nCONTENTS  \nA. Summary  \nB. System Design and Performance Requirements  \nC.  Submittals  \nD. Manufacturers  \nE.  Materials  \nF. Accessories or Special Features  \nG. Special Requirements  \nH. Installation Guidelines  \nI.  Quality Control  \nJ.  Cleaning and Adjusting  \nK. Warranty  \nA. Summary  \nThis section contains general design criteria for metal windows. Yale University has developed a specification for steel windows, which must be used by the architect.  \nB. System Design and Performance Requirements  \n1. Provide security screen design and application as approved by the Yale University Security Committee.  \n2. Metal windows must be commercial grade, high-performance windows of types required by the design or required to match existing window units.  \n3. Provide hardware for all operable windows.  \n4. Performance criteria:  \nWater infiltration—none at 20% of the design wind pressure  \nAir infiltration—none at 20% of the design wind pressure  \n– Fixed windows: 0.06 cfm per linear foot  \n– Operable windows: 0.10 cfm per linear foot of crack  \nThermal performance—the same as specified for insulating glass units  \nAcoustical performance—sound transmission class rating of 30–32  \nDeflection—not to exceed 1/175 of the unsupported spans  \nC. Submittals  \nSubmit the following documentation and samples to Yale University.  \n1. Shop Drawings  \nProvide shop drawings showing materials in place on the building, including coordination of related and adjoining work. Insert drawings and erection diagrams. Show the relative layout for all adjacent walls, beams, columns slabs, ceilings, and similar elements. Drawings must include elevations, floor plans, sections, and details. Details must be full–size and fully drawn, not outlined. Provide isometric details of any conditions, as requested by the architect.  \n2. Calculations  \nProvide structural calculations, sealed by a professional engineer licensed in the applicable state, and prepared in compliance with referenced documents and these standards. Where specifications and code differ, the more stringent requirements take precedence. Test reports are not an acceptable substitute for calculations.  \n3. Samples  \nSubmit samples of all materials to be encompassed in the work in the size and quantity required by the project documents, including extrusions, glass samples, and technical data.  \n4. Product Data  \nSubmit manufacturers' product data and specifications for any materials or fabrication techniques used in the curtain wall work. Include instructions or recommendations for installation and maintenance. Include certified test reports showing compliance with requirements where test methods are indicated.  \nD. Manufacturers  \nSubject to compliance with the design requirements, manufacturers offering products that may be incorporated in the work include, but are not limited to, the following.  \nEquivalent products from other manufacturers must be approved by Yale University.  \n1. Steel Windows  \nHopes Windows  \nCrittall  \nWindows  \n2. Aluminum Windows  \nKawneer  \nTubelite  \nWausau  \nAs approved by Yale University  \nE. Materials  \nProvide aluminum shapes and thicknesses as shown and as required to meet performance requirements. Use an alloy, with adequate structural characteristics, that is suitable for extruding and for finishing as specified. Comply with ASTMB221requirements for extrusions and ASTM B209 requirements for sheet and plate.  \nFormed sheet members must be at least .090\" thick. Form curved shapes accurately to the radius shown.  \nF. Accessories or Special Features  \n1. For each double hung operable window, provide unit aluminum framed screens, wit","cbCaiojSrut5WuaJ","https://ap.wps.com/l/cbCaiojSrut5WuaJ","pdf",265305,"English","# A. Summary\n# B. System Design and Performance Requirements\n# C. Submittals\n# D. Manufacturers\n# E. Materials\n# F. Accessories or Special Features\n# G. Special Requirements\n# H. Installation Guidelines\n# I. Quality Control\n# J. Cleaning and Adjusting\n# K. Warranty","[{\"question\":\"What are the required performance criteria for metal windows?\",\"answer\":\"The document specifies maximum limits for water infiltration and air infiltration at 20% of design wind pressure, thermal performance matching insulating glass units, acoustical performance with a sound transmission class of 30–32, and deflection not exceeding 1/175 of unsupported spans.\"},{\"question\":\"What must be submitted to Yale University before installing metal windows?\",\"answer\":\"Submittals include shop drawings showing coordinated layouts and elevations/sections/details, structural calculations sealed by a licensed professional engineer, material samples in required quantities and sizes, and manufacturers’ product data with installation/maintenance instructions and certified test reports where applicable.\"},{\"question\":\"How does the document handle quality control and warranty requirements?\",\"answer\":\"Quality control requires work to follow the AAMA Metal Curtain Wall guide specifications, maintenance of a manual on site, a single firm assuming undivided fabrication/installation responsibility with at least five years’ experience, and independent laboratory testing. Warranty requires a five-year manufacturer warranty covering system failures to meet specified requirements and glass breakage due to defined defects or installation issues for five years.\"}]","Metal Windows - Design Standards | PDF",13]