[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663120-105":59,"doc-detail-663120-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","metal-building-system-specifications-general","METAL BUILDING SYSTEM SPECIFICATIONS - General","","Metal Building System Specifications define the standard materials and components used in the design and fabrication of Miller Building Systems, Inc. metal building systems. The document outlines the building scope and describes major framing configurations, including gable, single slope, and lean-to options, along with standard roof slope, width, eave height, length, and bay spacing measurement rules. It also specifies required drawings for identification, assembly, anchor bolts, erection details, and certification expectations. Structural steel design references recognized standards and establishes criteria and tolerances, including design load requirements such as dead load, live load, wind, snow, and seismic, governed by applicable codes.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/metal-building-system-specifications-general/663120/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/metal-building-system-specifications-general/663120.png","ImageObject",300,407,{"name":92,"@type":93},"Tirek","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose and scope of these metal building system specifications?","Question",{"text":112,"@type":113},"They provide an outline of performance and the standard materials/components basis so architects, engineers, builders, and owners understand design, manufacture, and application. They also note that the specifications may change without notice and do not limit available Miller options unless contract documents require otherwise.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How are building width, length, eave height, and bay spacing measured?",{"text":117,"@type":113},"Width is measured outside-to-outside of the sidewall steel line, with different steel-line definitions for sheeted vs. open sidewalls. Eave height is measured from the bottom of the finished floor top to the roof/sidewall sheet intersection. Length is outside-to-outside of the endwall steel line, and bay spacing follows specified standard distances unless otherwise stated.",{"name":119,"@type":110,"acceptedAnswer":120},"Which standards and codes govern structural steel design and design loads?",{"text":121,"@type":113},"Structural steel design uses professionally recognized sources such as AISC, AISI, AWS, ASTM, MBMA, and SSPC, with Miller’s criteria governing unless contract documents state otherwise. Design loads include dead load plus live, wind, snow, and seismic loads as required by specified building codes, including the International Building Code, Standard Building Code, Uniform Building Code, and the National Building Code of Canada.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663120,1793225190,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},5909896572756,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","METAL BUILDING SYSTEM SPECIFICATIONS  \n1. GENERAL  \n1.1. SCOPE  \n1.1.1. The attached specifications cover the standard materials and components used in the design and fabrication of Miller Building Systems, Inc’s (“Miller”) metal building systems.  \n1.1.2. These specifications describe Miller’s “standard” metal building system. In the absence of contract requirements or restrictions to the contrary, these specifications accurately describe the product provided by Miller. However, these specifications are in no way intended to limit the available options associated with Miller’s metal building system.  \n1.1.3. These specifications are an outline of performance to insure that the architect, engineer, builder and/or owner understand the basis for design, manufacture and application of all Miller metal building systems.  \n1.1.4. Due to a continuing program of research and development, specifications in this manual are subject to change without notice.  \n1.2. BUILDING DESCRIPTION  \n1.2.1. Gable (SYM, UNSYM) is a continuous frame building. The primary frames have tapered columns and rafters with continuous sidewall girts bypassing the column or uniform depth columns and tapered rafters with Simple span sidewall girts inset into the column line. Also it may have one or more interior columns.  \n1.2.2. Single Slope (SS) is a continuous frame building. The primary frames have tapered columns and rafters with continuous sidewall girts bypassing the column or uniform depth columns and uniform depth or tapered rafters with Simple span sidewall girts inset into the column line. Also it may have one or more interior columns.  \n1.2.3. Lean-To (LT) is a single slope extension to a primary structure which provides structural support. These units usually have the same standard roof slope and girt design as the building to which they are attached.  \n1.3. BUILDING NOMENCLATURE  \n1.3.1. Standard Roof Slope  \n1.3.1.1 1/2” of rise for each 12” of horizontal run (Gable, Single Slope, Lean-To) .  \n1.3.1.2 1” of rise for each 12” of horizontal run (Gable, Single Slope, Lean-To) .  \n1.3.1.3 4” of rise for each 12” of horizontal run (Gable, Single Slope, Lean-To) .  \n1.3.2. Building “Width” is measured from outside to outside of sidewall steel line.  \n1.3.2.1 For sheeted sidewall, steel line is outside of sidewall girt.  \n1.3.2.2 For open sidewall, steel line is back of eave strut.  \n1.3.3. Building “Eave Height” is measured from the bottom of the top of finished floor to the intersection of the roof and sidewall sheets(top of eave strut in most cases) .  \n1.3.4. Building “Length” is measured from outside to outside of endwall steel line.  \n1.3.4.1 For sheeted endwall, steel line is outside of endwall girt.  \n1.3.4.2 For open endwall, steel line is outside of sheeting angle @ rake.  \n1.3.5. Standard “Bay Spacing” @ sidewall shall be 20’, 25’ or 30’, unless otherwise specified.  \n1.3.5.1 End bay space is measured from steel line to center line of frame.  \n1.3.5.2 Interior bay spaces are measured from center line to center line of frames.  \n1.3.6. Standard “Bay Spacing” @ endwall shall be 15’, or 20’, unless otherwise specified.  \n1.3.6.1 End bay space is measured from steel line to center line of endwall column.  \n1.3.6.2 Interior bay spaces are measured from center line to center line of endwall columns.  \n1.4. DRAWINGS & CERTIFICATION  \n1.4.1. Drawings: Miller shall furnish the following drawings with all metal building systems for the proper identification and assembly of building components.  \n1.4.2. Anchor Bolt Plan: Shows the diameter, location and projection of all anchor bolts for the components of the metal building system. Column/bracing reactions and base plate size will also be shown.  \n1.4.3. Erection Drawings: Complete erection (framing) drawings for the proper identification & assembly of all building components. These drawings will show main frame cross sections, sidewall, endwall and roof framing plans, sheeting/trim & insulation layouts. ","cbCainoXHq2sDqvW","https://ap.wps.com/l/cbCainoXHq2sDqvW","pdf",187561,11,"English","# 1. GENERAL\n## 1.1. SCOPE\n## 1.2. BUILDING DESCRIPTION\n## 1.3. BUILDING NOMENCLATURE\n## 1.4. DRAWINGS & CERTIFICATION\n# 2. STRUCTURAL STEEL DESIGN\n## 2.1. GENERAL\n## 2.2. DESIGN LOADS","[{\"question\":\"What is the purpose and scope of these metal building system specifications?\",\"answer\":\"They provide an outline of performance and the standard materials/components basis so architects, engineers, builders, and owners understand design, manufacture, and application. They also note that the specifications may change without notice and do not limit available Miller options unless contract documents require otherwise.\"},{\"question\":\"How are building width, length, eave height, and bay spacing measured?\",\"answer\":\"Width is measured outside-to-outside of the sidewall steel line, with different steel-line definitions for sheeted vs. open sidewalls. Eave height is measured from the bottom of the finished floor top to the roof/sidewall sheet intersection. Length is outside-to-outside of the endwall steel line, and bay spacing follows specified standard distances unless otherwise stated.\"},{\"question\":\"Which standards and codes govern structural steel design and design loads?\",\"answer\":\"Structural steel design uses professionally recognized sources such as AISC, AISI, AWS, ASTM, MBMA, and SSPC, with Miller’s criteria governing unless contract documents state otherwise. Design loads include dead load plus live, wind, snow, and seismic loads as required by specified building codes, including the International Building Code, Standard Building Code, Uniform Building Code, and the National Building Code of Canada.\"}]","METAL BUILDING SYSTEM SPECIFICATIONS - General | PDF",28]