[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646468-105":59,"doc-detail-646468-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","merlinnet-patient-care-network-arrhythmia-and-device-management-application-help-manual","Merlin.net™ Patient Care Network Arrhythmia and Device Management Application - Help Manual","","Help manual describing the Merlin.net Patient Care Network (PCN) Arrhythmia and Device Management Application for clinicians. It covers intended purpose, users, indications, intended patient population, and clinical benefits at a high level. It provides workflow guidance for logging in/out, using the Arrhythmia and Device Management features, reviewing recent transmissions, and managing patient lists and information. It also includes user profile, clinic administration, system requirements, data security, supported devices, follow-up sessions, troubleshooting, and symbol definitions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/merlinnet-patient-care-network-arrhythmia-and-device-management-application-help-manual/646468/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/merlinnet-patient-care-network-arrhythmia-and-device-management-application-help-manual/646468.png","ImageObject",300,407,{"name":92,"@type":93},"Connor ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-11","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the intended purpose of the Merlin.net™ PCN Arrhythmia and Device Management Application?","Question",{"text":112,"@type":113},"It enables authorized clinic personnel to view and remotely monitor an implanted heart device’s data and condition through the web portal using data received from a transmitter, programmer, or mobile application.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Who is the intended user population for this PCN application?",{"text":117,"@type":113},"It is intended to be used by, or under the supervision of, physicians or allied health professionals trained in managing implantable heart devices.",{"name":119,"@type":110,"acceptedAnswer":120},"Which patients and devices are indicated for remote monitoring?",{"text":121,"@type":113},"Remote monitoring is indicated for patients with bradyarrhythmias, tachyarrhythmias, sinus pauses, and/or heart failure who have compatible implantable heart devices. Specific patient selection should follow the compatible device IFUs.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646468,1792762178,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144,"preview_page_count":4},687207022233,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","[Merlin.net](Merlin.net)™ Patient Care Network Arrhythmia and Device Management Application  \nHelp Manual  \n™ Indicates a trademark of the Abbott group of companies.  \n‡ Indicates a third-party trademark, which is property of its respective owner. St. Jude Medical is a wholly-owned subsidiary of Abbott.  \nPat. [http://www.abbott.com/patents](http://www.abbott.com/patents)[ ](http://www.abbott.com/patents)© 2024 Abbott. All Rights Reserved.  \nContents  \nIntroduction.......................................................................................................... 1  \nIntended Purpose.................................................................................................................. 1  \nIntended Users.................................................................................................................... 1  \nIndications....................................................................................................................... 1  \nIntended Patient Population......................................................................................................... 1  \nIntended Clinical Benefits........................................................................................................... 1  \nLog In............................................................................................................... 2  \nPassword Requirements............................................................................................................ 2  \n[Merlin.net](Merlin.net) Applications............................................................................................................. 2  \nLog Out.......................................................................................................................... 2  \nArrhythmia and Device Management Application........................................................................... 3  \nClinic Types....................................................................................................................... 3  \nRecent Transmissions............................................................................................................... 3  \nPatient List....................................................................................................................... 5  \nPatient Information................................................................................................................ 7  \nTools............................................................................................................................ 8  \nYour User Profile and Preferences.................................................................................................... 9  \nClinic Administration............................................................................................................... 9  \nMobile DirectAlerts™ Application....................................................................................... 13  \nAdditional Information................................................................................................ 14  \nSystem Requirements............................................................................................................. 14  \nData Security.................................................................................................................... 14  \nSummary of Safety and Clinical Performance.......................................................................................... 14  \nUDI-DI Information............................................................................................................... 14  \nTechnical Support................................................................................................................. 14  \nPatient Selection................................................................................................................. 14  \nSupported Devices..........................................","cbCaiqQsOswzv5nY","https://ap.wps.com/l/cbCaiqQsOswzv5nY","pdf",2556812,22,"English","# Introduction\n## Intended Purpose\n## Intended Users\n## Indications\n## Intended Patient Population\n## Intended Clinical Benefits\n# Log In\n## Password Requirements\n# Merlin.net Applications\n## Log Out\n# Arrhythmia and Device Management Application\n## Clinic Types\n## Recent Transmissions\n## Patient List\n## Patient Information\n# Tools\n## Your User Profile and Preferences\n## Clinic Administration\n## Mobile DirectAlerts™ Application\n## Additional Information\n## System Requirements\n## Data Security\n## Summary of Safety and Clinical Performance\n## UDI-DI Information\n## Technical Support\n## Patient Selection\n## Supported Devices\n## Follow-up Sessions\n## Troubleshooting\n## Symbol Definitions","[{\"question\":\"What is the intended purpose of the Merlin.net™ PCN Arrhythmia and Device Management Application?\",\"answer\":\"It enables authorized clinic personnel to view and remotely monitor an implanted heart device’s data and condition through the web portal using data received from a transmitter, programmer, or mobile application.\"},{\"question\":\"Who is the intended user population for this PCN application?\",\"answer\":\"It is intended to be used by, or under the supervision of, physicians or allied health professionals trained in managing implantable heart devices.\"},{\"question\":\"Which patients and devices are indicated for remote monitoring?\",\"answer\":\"Remote monitoring is indicated for patients with bradyarrhythmias, tachyarrhythmias, sinus pauses, and/or heart failure who have compatible implantable heart devices. Specific patient selection should follow the compatible device IFUs.\"}]","Merlin.net™ Patient Care Network Arrhythmia and Device Management Application - Help Manual | PDF",55]