[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-651966-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-651966-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","mercury-system-manual-part-105933-00-safety-and-service-chapters","Mercury System Manual - Part 105933-00 - Safety and service chapters","","Mercury System Manual (Part Number 105933-00) provides installation, maintenance, and servicing guidance for Thermo Fisher Scientific Mercury System air quality instruments. It includes safety and equipment damage alerts describing DANGER, WARNING, CAUTION conditions and specific handling restrictions to prevent injury and property damage. The manual outlines operational support across chapters covering system installation and shutdown, calibration procedures, troubleshooting, preventive maintenance, optional equipment, and appendices for warranty, reference drawings, and firmware flowcharts.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/mercury-system-manual-part-105933-00-safety-and-service-chapters/651966/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/mercury-system-manual-part-105933-00-safety-and-service-chapters/651966.png","ImageObject",300,407,{"name":42,"@type":43},"Dewi_Sukmawati","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-28","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What topics are covered in the Mercury System Manual?","Question",{"text":62,"@type":63},"The manual covers installing, maintaining, and servicing the Mercury System, including safety alerts and equipment-damage warnings. It also provides structured access to operation and service information through multiple chapters and appendices.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What are the key safety alert levels used in the manual?",{"text":67,"@type":63},"The manual describes DANGER, WARNING, and CAUTION alerts. Each level explains the risk severity if guidance is ignored, including potential personal injury and equipment/property damage.",{"name":69,"@type":60,"acceptedAnswer":70},"What handling and grounding precautions does the manual emphasize?",{"text":71,"@type":63},"The manual instructs qualified service personnel only for service procedures and warns against defeating the three-wire grounding system. It also recommends using an antistatic wrist strap when handling internal components and handling printed circuit boards by edges only.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},651966,1792929137,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145},962094243415,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","Mercury System Manual  \nPart Number 105933-00  \n7Nov2016  \n© 2007 Thermo Fisher Scientific Inc. All rights reserved.  \nSpecifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.  \nThermo Fisher Scientific Air Quality Instruments  \n27 Forge Parkway Franklin, MA 02038 1-508-520-0430 [www.thermo.com/aqi](www.thermo.com/aqi)  \nAbout This Manual  \nThis manual provides information about installing, maintaining, and servicing the Mercury System. It also contains important alerts to ensure safe operation and prevent equipment damage. The manual is organized into the following chapters and appendices to provide direct access to specific operation and service information.  \n● Chapter 1 “Introduction” provides an overview of Mercury System instruments and describes associated Mercury System components.  \n● Chapter 2 “System Installation, Set Up and Shut Down” describes how to setup, start up, and shut down the instrument. It also provides the recommended initial parameter settings.  \n● Chapter 3 “Calibration” provides the manual system calibration procedure, the auto system calibration procedure, and the calibration check procedure.  \n● Chapter 4 “Troubleshooting” presents guidelines for diagnosing instrument failures, isolating faults, and includes recommended actions for restoring proper operation.  \n● Chapter 5 “Preventive Maintenance” describes the periodic maintenance procedures that should be performed on the system instruments and components to ensure proper operation.  \n● Chapter 6 “Optional Equipment” describes the optional equipment that can be used with the Mercury System.  \n● Appendix A “Warranty” is a copy of the warranty statement.  \n● Appendix B “System Reference Drawings” provides the plumbing and electrical drawings for the Mercury System instruments and associated components.  \n● Appendix C “Flowcharts of Menu-Driven Firmware” presents detailed flowcharts for the 80i and the 81i menu-driven firmware. They are provided here for convenience in navigating the Mercury System menus and screens.  \nThermo Fisher Scientific Mercury System Manual i  \nSafety and Equipment Damage Alerts  \nThis manual contains important information to alert you to potential safety hazards and risks of equipment damage. Refer to the following types of alerts you may see in this manual.  \nSafety and Equipment Damage Alert Descriptions  \nAlert Description  \nDANGER  \nWARNING  \nCAUTION  \nEquipment Damage  \nA hazard is present that will result in death or serious personal injury if the warning is ignored. ▲  \nA hazard is present or an unsafe practice can result in serious personal injury if the warning is ignored. ▲  \nThe hazard or unsafe practice could result in minor to moderate personal injury if the warning is ignored. ▲  \nThe hazard or unsafe practice could result in property damage if the warning is ignored. ▲  \nSafety and Equipment Damage Alerts in this Manual and in the individual Mercury instruction manuals.  \nAlert Description  \nWARNING If the equipment is operated in a manner not specified by  \nthe manufacturer, the protection provided by the equipment may be impaired. ▲  \nThe service procedures in this manual are restricted to qualified service personnel only. ▲  \nThis product is supplied with a three-wire grounding cord. Under no circumstances should this grounding system be defeated. ▲  \nEquipment Damage Do not attempt to lift the instrument by the cover or other external fittings. ▲  \nTo prevent damaging the probe transducer, read the cable labels carefully and DO NOT connect the C or D cable to the wrong connector on the 82i rear panel.  \nSome internal components can be damaged by small amounts of static electricity. A properly ground antistatic wrist strap must be worn while handling any internal component. If an antistatic wrist strap is not available, be sure to touch the instrument chassis before touching any internal components.","cbCaifc122BwESYn","https://ap.wps.com/l/cbCaifc122BwESYn","pdf",7880029,110,"English","# About This Manual\n# Safety and Equipment Damage Alerts\n# Where to Get Help\n# Contents\n## Chapter 1 Introduction","[{\"question\":\"What topics are covered in the Mercury System Manual?\",\"answer\":\"The manual covers installing, maintaining, and servicing the Mercury System, including safety alerts and equipment-damage warnings. It also provides structured access to operation and service information through multiple chapters and appendices.\"},{\"question\":\"What are the key safety alert levels used in the manual?\",\"answer\":\"The manual describes DANGER, WARNING, and CAUTION alerts. Each level explains the risk severity if guidance is ignored, including potential personal injury and equipment/property damage.\"},{\"question\":\"What handling and grounding precautions does the manual emphasize?\",\"answer\":\"The manual instructs qualified service personnel only for service procedures and warns against defeating the three-wire grounding system. It also recommends using an antistatic wrist strap when handling internal components and handling printed circuit boards by edges only.\"}]","Mercury System Manual - Part 105933-00 - Safety and service chapters | PDF",1792877534,277]