[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-340581-105":59,"doc-detail-340581-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","measurement-of-tissue-optical-properties-in-the-400-to-700-nm-range-to-assess-light-penetration-depths-for-laser-treatment-of-upper-tract-urothelial-carcinomas","Measurement of tissue optical properties in the 400 to 700 nm range to assess light penetration depths for laser treatment of upper tract urothelial carcinomas","","Therapeutic strategies for upper tract urothelial carcinomas require tissue absorption (μa) and reduced scattering (μ0s) coefficients to quantify how laser light distributes during treatment. Human ureter, fatty tissue, ureteral/renal pelvic carcinomas, and porcine ureter and fatty tissue are measured from 400 to 700 nm to determine projected light penetration depths (δ). Optical properties are obtained using a double integrating sphere system and inverse Monte Carlo methods, then δ is computed and compared across normal versus cancerous human tissues and across human versus porcine tissues, supporting evaluation of ex vivo models.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/measurement-of-tissue-optical-properties-in-the-400-to-700-nm-range-to-assess-light-penetration-depths-for-laser-treatment-of-upper-tract-urothelial-carcinomas/340581/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/measurement-of-tissue-optical-properties-in-the-400-to-700-nm-range-to-assess-light-penetration-depths-for-laser-treatment-of-upper-tract-urothelial-carcinomas/340581.png","ImageObject",300,407,{"name":92,"@type":93},"Clementine","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-01","2026-09-22",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why are μa and μ0s coefficients important for laser treatment of UTUC?","Question",{"text":112,"@type":113},"They are essential parameters used to quantitatively model how light absorption and scattering occur in tissue, which determines the spatial distribution of light and treatment effects.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How were the optical properties in the 400–700 nm range measured?",{"text":117,"@type":113},"The study used a double integrating sphere optical system and inverse Monte Carlo methods to determine μa and μ0s from measured diffuse reflectance and total transmittance.",{"name":119,"@type":110,"acceptedAnswer":120},"What does δ represent and how was it used in the comparisons?",{"text":121,"@type":113},"δ is the projected light penetration depth calculated from μa and μ0s. It was compared between normal and cancerous human tissues and between human and porcine tissues to evaluate differences in light distribution.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},340581,1790196761,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},1374391974564,"https://ap-avatar.wpscdn.com/avatar/14000253aa45c000a9e?x-image-process=image/resize,m_fixed,w_180,h_180&k=1779874745381141002","RESEARCH PAPER  \nMeasurement of tissue optical properties in the 400 to 700 nm range to assess light penetration depths for laser treatment of upper tract urothelial carcinomas  \nHimemi Watabe,a,† Yu Shimojo,a,b,c,*,† Asako Shingu,d Hidenori Ito,d Hideo Fukuhara,e Makito Miyake,f Keiji Inoue,e Kiyohide Fujimoto,f  \nand Takahiro Nishimuraa,*  \naOsaka University, Graduate School of Engineering, Osaka, Japan  \nbOsaka Metropolitan University, Graduate School of Medicine, Osaka, Japan  \ncResearch Fellow of Japan Society for the Promotion of Science, Tokyo, Japan  \ndSBI Pharmaceuticals Co. , Ltd. , Tokyo, Japan  \neKochi Medical School, Department of Urology, Kochi, Japan  \nfNara Medical University, Department of Urology, Nara, Japan  \n\n| ABSTRACT. Significance: For therapeutic approaches for upper tract urothelial carcinomas, the absorption μa and reduced scattering μ0s coefficients of these tissues are essential parameters to quantitatively evaluate the distribution of light treatment effects. Aim: The μa and μ0s spectra of the human ureter, fatty tissue, ureteral and renal pelvic carcinomas, and porcine ureter and fatty tissue are measured over 400 to\u003Cbr>700 nm to evaluate projected light penetration depths δ .\u003Cbr>Approach: The optical properties were determined with a double integrating sphere optical system and inverse Monte Carlo methods. δ was calculated and compared between normal and cancerous human tissues as well as between normal human and porcine tissues.\u003Cbr>Results: μa and μ0s spectra of each tissue were determined. The δ of the normal human ureter was less than those of the ureteral and renal pelvic carcinomas, whereas that of the porcine ureter was similar to that of the human ureter over\u003Cbr>400 to 600 nm and ∼0 .2 times smaller above 600 nm.\u003Cbr>Conclusion: Optical properties of human and porcine upper urinary tracts provide insights into light distributions and the validity of ex vivo porcine models in preclinical evaluations of laser treatments.\u003Cbr>© The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. [DOI: 10.1117/1.JBO.29.12.125001]\u003Cbr>Keywords: upper urinary tract; optical properties; light penetration depth; human tissue; laser treatment; upper tract urothelial carcinoma\u003Cbr>Paper 240235GR received Aug. 20, 2024; revised Nov. 19, 2024; accepted Nov. 22, 2024; published Dec.\u003Cbr>10, 2024 . |\n| --- |\n| 1 Introduction\u003Cbr>Upper tract urothelial carcinoma (UTUC) is a malignant tumor occurring in the urothelial mucosa of the ureter and renal pelvis. Radical nephroureterectomy has been considered the |\n\n*Address all correspondence to Yu Shimojo, [x22800k@omu.ac.jp](x22800k@omu.ac.jp); Takahiro Nishimura, [nishimura-t@see.eng.osaka-u.ac](nishimura-t@see.eng.osaka-u.ac)[.jp](.jp)  \n†These authors contributed equally to this work.  \nJournal of Biomedical Optics 125001-1 December 2024 • Vol. 29(12)  \nWatabe et al.: Measurement of tissue optical properties in the 400 to 700 nm range. . .  \nstandard of care.1,2 This procedure has been overused for low-grade tumors with little risk of metastatic progression, and even for some early-stage high-grade superficial tumors,3,4 leading to increased interest in organ-sparing strategies to preserve renal function. One of the most promising strategies is an endoscopic approach using laser light that can be delivered minimally invasively via an optical fiber and can interact specifically with tumors.5 These modalities include photodynamic therapy (PDT)6 and laser ablation (LA) .7 Laser-tissue interactions in these treatments are related to optical absorption and scattering by the tumors, making information on the spatial distribution of light in the tissue crucial for estimating treatment effects.8  \nThe light distribution in the tissue can be analyzed using absorption (μa ) and reduced scattering (μ0s) coefficie","cbCaihSmEGcPtRIG","https://ap.wps.com/l/cbCaihSmEGcPtRIG","pdf",1908626,13,"English","# Abstract\n# 1 Introduction\n## Clinical context of UTUC and organ-sparing laser approaches\n## Optical parameters and need for visible-wavelength spectra\n## Study objective and measurement strategy","[{\"question\":\"Why are μa and μ0s coefficients important for laser treatment of UTUC?\",\"answer\":\"They are essential parameters used to quantitatively model how light absorption and scattering occur in tissue, which determines the spatial distribution of light and treatment effects.\"},{\"question\":\"How were the optical properties in the 400–700 nm range measured?\",\"answer\":\"The study used a double integrating sphere optical system and inverse Monte Carlo methods to determine μa and μ0s from measured diffuse reflectance and total transmittance.\"},{\"question\":\"What does δ represent and how was it used in the comparisons?\",\"answer\":\"δ is the projected light penetration depth calculated from μa and μ0s. It was compared between normal and cancerous human tissues and between human and porcine tissues to evaluate differences in light distribution.\"}]","Measurement of tissue optical properties in the 400 to 700 nm range to assess light penetration depths for laser treatment of upper tract urothelial carcinomas | PDF",1790037493,33,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/e3dd7076a539dc04dad7ee007e6c4593.webp",983,1272,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/926700d060d39f93460b3daa1d9ccfdd.webp",982,1270,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/5e7000c01f848d4060a4dd559bd80816.webp",981,1269,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/c3be77d8b81d4659765d7099a95fc903.webp",980,1268]