[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-662953-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-662953-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","me7x8j11ae-electrical-schematic-diagrams","ME7X8J11AE - Electrical Schematic Diagrams","","Electrical schematic and component parts documentation for a Milnor system, covering an overview, schematic/electrical parts references, and a detailed table of contents. Sections guide the reader to component part lists, limited standard warranty information, repair component sourcing, and usage of Milnor electrical schematic diagrams. The manual includes multiple diagram types such as 3-phase and multi-volt motor connections, control box layouts, board-to-board wiring, flushing supplies, control circuit transformers, microprocessor inputs, and start/door and variable speed controller wiring.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/me7x8j11ae-electrical-schematic-diagrams/662953/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/me7x8j11ae-electrical-schematic-diagrams/662953.png","ImageObject",300,407,{"name":42,"@type":43},"Dewi_Sukmawati","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":22},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What does the manual include?","Question",{"text":62,"@type":63},"It provides Milnor schematic/electrical parts references, a component parts list, and detailed entries for multiple control and wiring diagrams. It also includes warranty and instructions for obtaining repair components.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"How can I use the Milnor electrical schematic diagrams referenced in the document?",{"text":67,"@type":63},"The table of contents includes a dedicated section titled “How to Use Milnor® Electrical Schematic Diagrams,” indicating the manual’s guidance for interpreting and applying the diagrams.",{"name":69,"@type":60,"acceptedAnswer":70},"Which kinds of electrical topics are covered by the diagrams?",{"text":71,"@type":63},"Covered topics include motor connection diagrams (3-phase and multivolt), control box layouts, board-to-board wiring changes, flushing chemical supplies, speed limits, electric heat/valves, and start/door and variable speed controller circuitry.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},662953,1793223761,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":79,"read_time":144},962094243415,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","Published Manual Number/ECN: ME7X8J11AE/2015436A  \n• Publishing System: TPAS2  \n• Access date: 10/27/2015  \n• Document ECNs: Latest  \nSchematic/Electrical Parts  \nMWF45J8, MWF63J7, MWF77J7 30022X8J, 36026X8J, 42026X7J, 42032X7J, 48040F7J/B  \nwith H-Type Controls  \nPELLERIN MILNOR CORPORATION POST OFFICE BOX 400, KENNER, LOUISIANA 70063-0400, U.S.A.  \nTable of Contents  \nME7X8J11AE/15436A  \nPage Description Document  \n1 Component Parts List W7X8JPL/2015436N  \n9 Limited Standard Warranty BMP720097/2008272A  \n10 How to Get the Necessary Repair Components BIUUUD19/20081231  \n11 How to Use Milnor® Electrical Schematic Diagrams BIUUUK01/20130308  \n24 Sample Schematic BMP010012/2001503N  \n26 3 Phase Motor Connection Diagram BMP850029/1999362B  \n27 3P Motor Diagram-Multivolt W80008/2001253A  \n28 Control Box Layouts 30\" through 42\" W7X8JTG1/2006393B  \n30 Control Box Layouts Sheet 2 W7X8JTG2/2012316B  \n32 Board to Board Wiring before 12-15-03 W7X8JBW/2003022B  \n34 Board to Board Wiring after 12-15-03 W7X8JBWA/2012232B  \n36 Flushing Supplies W7X8JCF/2012232B  \n38 Optional 12 Chemical Flushing W7X8JCM/2012232B  \n40 Extract Speed Limit W7X8JEC/2012232B  \n42 Electric heat W7X8JEH/2012396B  \n44 Electric Valves W7X8JEV/2015205B  \n46 Electric Valves for 48040B7B only W7X8JEVA/2012232B  \n48 Hydraulic Door (48040 Only) W7X8JHD/2012232B  \n50 Control Circuit Transformers W7X8JLV/2012232B  \n52 Microprocessor Inputs W7X8JIA/2012233B  \n54 Raise House (48040X7B only) W7X8JRH/2012233B  \n56 Start & Door Circuit 30022X8J W7X8JS+/2015436B  \n58 Start & Door Circuit 36X8J, 42X7J W7X8JS+A/2015436B  \n60 Start Circuit for48040F7B only W7X8JS+B/2015436B  \n62 Start & Door Circuit 4840F7J only W7X8JS+C/2015436B  \n64 Variable Speed Controller (3PH) W7X8JVPA/2015163B  \n66 Variable Speed Controller (1PH) W7X8JVPB/2015163B  \n68 Variable Speed Controller (3PH) 48040F7J/B W7X8JVPC/2012233B  \nC O M P O N E N T P A R T S L I S T W7X8JPL/2015436N  \n1  \nCOMPONENT  \nNUMBER  \n1  \n2  \n3 ACBA  \nBA  \nBADV  \nBADV  \nBADV  \nBAFR  \nBAFR  \nBAUP  \nBAUP  \nBAUP  \nBBAD-1  \nCL  \nCLA  \nCLA  \nCLA  \nCLA-CHOKE  \nCLA-CHOKE  \nCLA-CHOKE  \nCR  \nCRA  \nCRA  \nCRALT  \nCRC1  \nCRC2  \nCRC3  \nCRC4  \nCRC5  \nCRC6  \nCRD  \nFUNCTION OF THIS COMPONENT NUMBER >>CONTROL BOX LAYOUTS  \nDETAILS X8J CONTROL PANEL  \nDETAILS X8J CONTROL PANEL  \nDETAILS X8J CONTROL PANEL BOARD-ACCELEROMETER  \n>>PRINTED CIRCUIT BOARDS  \nBOARD=DISPLAY/SWITCH PANEL  \nBOARD=DISPLAY/SWITCH PANEL \u003CMODEL AZ  \nBOARD=DISPLAY/SWITCH PANEL >MODEL AZ BOARD-FUSE / RELAY  \nBOARD-FUSE / RELAY BOARD=PROCESSOR+I/O  \nBOARD=PROCESSOR+I/O \u003CMODEL AZ  \nBOARD=PROCESSOR+I/O >MODEL AZ BOARD-A TO D CONVERTER  \n>>RELAY-LATCH  \nRELAY-DOOR SEAL  \nRELAY-DOOR SEAL  \nRELAY-DOOR SEAL  \nCHOKE-DOOR SEAL LATCH  \nCHOKE-DOOR SEAL LATCH  \nCHOKE-DOOR SEAL LATCH  \n>>RELAY-PILOT OR CONTROL  \nRELAY-DOOR OPEN  \nRELAY-DOOR OPEN  \nRELAY-OUT OF BALANCE TOO LARGE RELAY-FLUSH CHEMICAL \\#1  \nRELAY-FLUSH CHEMICAL \\#2  \nRELAY-FLUSH CHEMICAL \\#3  \nRELAY-FLUSH CHEMICAL \\#4  \nRELAY-FLUSH CHEMICAL \\#5  \nRELAY-FLUSH CHEMICAL \\#6 RELAY-OK TO OPEN DOOR  \nWHERE TO FIND  \nTHIS COMPONENT  \nW7X8JTG1  \nW7X8JTG2  \nW7X8JTG2  \nW7X8JEC  \nW7X8JBW  \nW7X8JBWA  \nW7X8JBWA  \nW7X8JS+  \nW7X8JS+A  \nW7X8JBW  \nW7X8JBWA  \nW7X8JBWA  \nW7X8JEC  \nW7X8JS+A  \nW7X8JS+B  \nW7X8JS+C  \nW7X8JS+A  \nW7X8JS+B  \nW7X8JS+C  \nW7X8JS+B  \nW7X8JS+C  \nW7X8JEC  \nW7X8JCM  \nW7X8JCM  \nW7X8JCM  \nW7X8JCM  \nW7X8JCM  \nW7X8JCM  \nW7X8JS+  \nMILNOR P/N  \nB2T2002039  \nB2T2004035  \nB2T2000021  \nEACCLRM3  \n08BHEPSPBT  \n08BHEPSPCT  \n98CMCR1823  \n08BHFRCT  \n08BHFRCT  \n08BH18EPDT  \n08BH18EPDT  \n98CMCR1822  \n08BSBADCTE  \n09CL2C-C71  \n09CL2C-C71  \n09CL2C-C71  \n10YCLCHOKE  \n10YCLCHOKE  \n10YCLCHOKE  \n09C024D71  \n09C024D71  \n09C024D71  \n09C024D71  \n09C024D71  \n09C024D71  \n09C024D71  \n09C024D71  \n09C024D71  \n09C024D71  \nDESCRIPTION  \n3022,3626X8J CONTROL PANEL 48040F7J/B WITH H CONTROLS LOW VOLT 48040F7J/B/N/W HIGH VOLT CONTROL ASSY:ACCEL O-5VOC OP STAPH 42  \nBD:EP+ SW PANEL VER2->TESTEP+ SWPNL VER2 W/LCD>TEST BD:EP PLUS DISPLAY  \nBD-T/V/X START CIRCUIT->TEST","cbCaivUoQiZTOAmU","https://ap.wps.com/l/cbCaivUoQiZTOAmU","pdf",3712781,73,"English","# Table of Contents\n## Component Parts List\n## Limited Standard Warranty\n## How to Get the Necessary Repair Components\n## How to Use Milnor Electrical Schematic Diagrams\n## Sample Schematic\n## 3 Phase Motor Connection Diagram\n## 3P Motor Diagram-Multivolt\n## Control Box Layouts 30\" through 42\"\n## Control Box Layouts Sheet 2\n## Board to Board Wiring before 12-15-03\n## Board to Board Wiring after 12-15-03\n## Flushing Supplies\n## Optional 12 Chemical Flushing\n## Extract Speed Limit\n## Electric heat\n## Electric Valves\n## Electric Valves for 48040B7B only\n## Hydraulic Door (48040 Only)\n## Control Circuit Transformers\n## Microprocessor Inputs\n## Raise House (48040X7B only)\n## Start & Door Circuit 30022X8J\n## Start & Door Circuit 36X8J, 42X7J\n## Start Circuit for 48040F7B only\n## Start & Door Circuit 4840F7J only\n## Variable Speed Controller (3PH)\n## Variable Speed Controller (1PH)\n## Variable Speed Controller (3PH) 48040F7J/B\n## Component Parts List (C O M P O N E N T P A R T S L I S T)","[{\"question\":\"What does the manual include?\",\"answer\":\"It provides Milnor schematic/electrical parts references, a component parts list, and detailed entries for multiple control and wiring diagrams. It also includes warranty and instructions for obtaining repair components.\"},{\"question\":\"How can I use the Milnor electrical schematic diagrams referenced in the document?\",\"answer\":\"The table of contents includes a dedicated section titled “How to Use Milnor® Electrical Schematic Diagrams,” indicating the manual’s guidance for interpreting and applying the diagrams.\"},{\"question\":\"Which kinds of electrical topics are covered by the diagrams?\",\"answer\":\"Covered topics include motor connection diagrams (3-phase and multivolt), control box layouts, board-to-board wiring changes, flushing chemical supplies, speed limits, electric heat/valves, and start/door and variable speed controller circuitry.\"}]","ME7X8J11AE - Electrical Schematic Diagrams | PDF",184]