[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-500491-105":59,"doc-detail-500491-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","maxwell-fsc-dna-iq-casework-kit-instructions-for-use-1-description","Maxwell® FSC DNA IQ™ Casework Kit - Instructions for Use - 1. Description","","Technical manual for using the Maxwell® FSC DNA IQ™ Casework Kit with specified Maxwell® instruments to achieve optimal DNA extraction from forensic casework samples. It describes the kit’s purpose for DNA yield and purity for STR analysis, supported instrument models, and how processing works with prefilled reagent cartridges and magnetic-particle handling. It also covers related components, storage conditions, and notes on preprocessing using 1-Thioglycerol and optional Maxprep™ Liquid Handler workflows.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/maxwell-fsc-dna-iq-casework-kit-instructions-for-use-1-description/500491/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/maxwell-fsc-dna-iq-casework-kit-instructions-for-use-1-description/500491.png","ImageObject",300,407,{"name":92,"@type":93},"McGucket","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-16","2026-10-03",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the Maxwell® FSC DNA IQ™ Casework Kit used for?","Question",{"text":112,"@type":113},"It is used with compatible Maxwell® instruments to extract DNA from forensic casework samples, including blood stains, semen stains, hair, cigarette butts, tissue samples, and “touch” DNA samples.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which preprocessing reagent is recommended instead of DTT?",{"text":117,"@type":113},"The manual instructs using 1-Thioglycerol for sample preprocessing, noting it can be stored at 2–10°C and provides extraction performance comparable to DTT.",{"name":119,"@type":110,"acceptedAnswer":120},"How can samples be preprocessed before running on the Maxwell® instruments?",{"text":121,"@type":113},"Samples can be preprocessed manually or using the Maxprep™ Liquid Handler, which prepares samples and can load them into Maxwell® FSC cartridges and dispense elution buffer.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},500491,1791295316,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},1236954412713,"https://us-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","FSS.0001.0001.0987  \nT E C H N I C A L M A N U A L  \nMaxwell® FSC DNA IQ™ Casework Kit  \nInstructions for Use of Products  \nAS1550 and DC6745  \nNote: To use the Maxwell® FSC DNA IQ™ Casework Kit, you must have the “DNA IQ Casework” method loaded on the Maxwell® Instrument.  \nCaution: Handle cartridges with care; seal edges maybe sharp.  \nRevised 8/21 TM499  \nFSS.0001.0001.0988  \nMaxwell® FSC DNA IQ™ Casework Kit  \nAll technical [literature is available at: www.promega.com/protocols/](literature is available at: www.promega.com/protocols/)[ ](literature is available at: www.promega.com/protocols/)Visit the web site to verify that you are using the most current version of this Technical Manual. E-mail Promega Technical Services if you have questions on use of this system:  \n1. Description......................................................................................................................................... 1  \n2. Product Components and Storage Conditions ........................................................................................ 2  \n3. Sample Preprocessing ......................................................................................................................... 3  \n3.A. Samples on a Solid Support ......................................................................................................... 3  \n3.B. Liquid Samples........................................................................................................................... 5  \n3.C. Differential Extraction Samples ................................................................................................... 6  \n4. Maxwell® FSC DNA IQ™ Casework Cartridge Preparation .....................................................................8  \n5. Maxprep™ Preprocessing .................................................................................................................... 9  \n6. Maxwell® Instrument Setup and Run .................................................................................................... 9  \n7. Storing Eluted DNA........................................................................................................................... 11  \n8. Troubleshooting................................................................................................................................ 12  \n9. Related Products............................................................................................................................... 14  \n10. Summary of Changes ......................................................................................................................... 14  \n1. Description  \nThe Maxwell® FSC DNA IQ™ Casework Kit(a) is used with the Maxwell® Instruments specified below and is specifically designed for optimal DNA extraction from forensic casework samples. These samples include blood stains, semen stains, hair, cigarette butts, tissue samples and “touch” DNA samples regularly encountered in forensic DNA analysis.  \nExtraction from certain sample types (e.g., sperm cells) traditionally requires the use of dithiothreitol (DTT) as part of the extraction method. The Casework Extraction Kit (Cat.\\# DC6745) includes 1-Thioglycerol, which, unlike DTT, can be stored at 2–10°C, and provides extraction performance comparable to that with DTT. This Technical Manual provides instructions to use 1-Thioglycerol for sample preprocessing.  \nSupported Instruments  \nInstrument Cat.\\# Technical Manual  \n\n| Maxwell® RSC | AS4500 | TM411 |\n| --- | --- | --- |\n| Maxwell® RSC 48 | AS8500 | TM510 |\n| Maxwell® FSC | AS4600 | TM462 |\n| Maxprep™ Liquid Handler | AS9100, AS9101, AS9200, AS9201 | TM509 |\n\nPromega Corporation · 2800 Woods Hollow Road · Madison, WI 53711-5399 USA · Toll Free in USA 800-356-9526 · 608-274-4330 · Fax 608-277-2516 1  \n[www.promega.com](www.promega.com) TM499 ·Revised 8/21  \nFSS.0001.0001.0989  \n1. Description (continued)  \nMaxwell® Instruments are designed ","cbCaioSx9E2C2cU4","https://ap.wps.com/l/cbCaioSx9E2C2cU4","pdf",17836330,362,"English","# 1. Description\n## Supported Instruments\n# 2. Product Components and Storage Conditions\n# 3. Sample Preprocessing\n## 3.A. Samples on a Solid Support\n## 3.B. Liquid Samples\n## 3.C. Differential Extraction Samples\n# 4. Maxwell® FSC DNA IQ™ Casework Cartridge Preparation\n# 5. Maxprep™ Preprocessing\n# 6. Maxwell® Instrument Setup and Run\n# 7. Storing Eluted DNA\n# 8. Troubleshooting\n# 9. Related Products\n# 10. Summary of Changes","[{\"question\":\"What is the Maxwell® FSC DNA IQ™ Casework Kit used for?\",\"answer\":\"It is used with compatible Maxwell® instruments to extract DNA from forensic casework samples, including blood stains, semen stains, hair, cigarette butts, tissue samples, and “touch” DNA samples.\"},{\"question\":\"Which preprocessing reagent is recommended instead of DTT?\",\"answer\":\"The manual instructs using 1-Thioglycerol for sample preprocessing, noting it can be stored at 2–10°C and provides extraction performance comparable to DTT.\"},{\"question\":\"How can samples be preprocessed before running on the Maxwell® instruments?\",\"answer\":\"Samples can be preprocessed manually or using the Maxprep™ Liquid Handler, which prepares samples and can load them into Maxwell® FSC cartridges and dispense elution buffer.\"}]","Maxwell® FSC DNA IQ™ Casework Kit - Instructions for Use - 1. Description | PDF",1791012008,912]