[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-361471-105":59,"doc-detail-361471-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","maximum-number-of-conductors-in-rigid-metal-conduit-rmc-fill-chart","Maximum Number of Conductors in Rigid Metal Conduit (RMC) - Fill Chart","","Maximum number of conductors for concentric stranded wiring in rigid metal conduit (RMC) is provided as a fill chart. The table lists conductor counts by conductor type (THHN, THWN, THWN-2) across multiple conductor sizes (AWG/kcmil) and corresponding conduit trade sizes (metric designators). Notes clarify this chart’s scope, and direct readers to Table C.8(A) for compact stranded conductors. Copyright and reproduction permissions from NFPA 70 (2023) are included, along with source contact information.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/maximum-number-of-conductors-in-rigid-metal-conduit-rmc-fill-chart/361471/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/maximum-number-of-conductors-in-rigid-metal-conduit-rmc-fill-chart/361471.png","ImageObject",300,407,{"name":92,"@type":93},"Well Done","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-15","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",13,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What conduit type and installation scenario does this chart cover?","Question",{"text":113,"@type":114},"The chart covers rigid metal conduit (RMC) and gives the maximum conductor fill for concentric stranded conductors.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Which conductor types are listed in the fill table?",{"text":118,"@type":114},"The table lists THHN, THWN, and THWN-2 conductor types.",{"name":120,"@type":111,"acceptedAnswer":121},"Does the chart apply to compact stranded conductors?",{"text":122,"@type":114},"No. It states that for compact stranded conductors, Table C.8(A) should be used instead.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},361471,1790269838,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":81,"preview_page_count":8,"preview_urls":145},5909892210082,"https://ap-avatar.wpscdn.com/avatar/56001069da27c9f41e8?x-image-process=image/resize,m_fixed,w_180,h_180&k=1789614185077863061","Maximum Number of Conductors or Fixture Wires in  \nRigid Metal Conduit (RMC)  \n\n| Type | Conductor\u003Cbr>.\u003Cbr>Size\u003Cbr>.\u003Cbr>(AWG/\u003Cbr>.\u003Cbr>kcmil) | Trade Size (Metric Designator) |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  | 3/8\u003Cbr>.\u003Cbr>(12) | 1/2\u003Cbr>.\u003Cbr>(16) | 3/4\u003Cbr>.\u003Cbr>(21) | 1\u003Cbr>.\u003Cbr>(27) | 1 1/4\u003Cbr>.\u003Cbr>(35) | 1 1/2\u003Cbr>.\u003Cbr>(41) | 2\u003Cbr>.\u003Cbr>(53) | 2 1/2\u003Cbr>.\u003Cbr>(63) | 3\u003Cbr>.\u003Cbr>(78) | 3 1/2\u003Cbr>.\u003Cbr>(91) | 4\u003Cbr>.\u003Cbr>(103) | 5\u003Cbr>.\u003Cbr>(129) | 6\u003Cbr>.\u003Cbr>(155) |\n\nCONDUCTORS  \n| THHN,\u003Cbr>THWN,\u003Cbr>THWN-2 | 14 | — | 13 | 22 | 36 | 63 | 85 | 140 | 200 | 309 | 412 | 531 | 833 | 1202 |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  | 12 | — | 9 | 16 | 26 | 46 | 62 | 102 | 146 | 225 | 301 | 387 | 608 | 877 |\n|  | 10 | — | 6 | 10 | 17 | 29 | 39 | 64 | 92 | 142 | 189 | 244 | 383 | 552 |\n|  | 8 | — | 3 | 6 | 9 | 16 | 22 | 37 | 53 | 82 | 109 | 140 | 221 | 318 |\n|  | 6 | — | 2 | 4 | 7 | 12 | 16 | 27 | 38 | 59 | 79 | 101 | 159 | 230 |\n|  | 4 | — | 1 | 2 | 4 | 7 | 10 | 16 | 23 | 36 | 48 | 62 | 98 | 141 |\n|  | 3 | — | 1 | 1 | 3 | 6 | 8 | 14 | 20 | 31 | 41 | 53 | 83 | 120 |\n|  | 2 | — | 1 | 1 | 3 | 5 | 7 | 11 | 17 | 26 | 34 | 44 | 70 | 100 |\n|  | 1 | — | 1 | 1 | 1 | 4 | 5 | 8 | 12 | 19 | 25 | 33 | 51 | 74 |\n|  | 1/0 | — | 1 | 1 | 1 | 3 | 4 | 7 | 10 | 16 | 21 | 27 | 43 | 63 |\n|  | 2/0 | — | 0 | 1 | 1 | 2 | 3 | 6 | 8 | 13 | 18 | 23 | 36 | 52 |\n|  | 3/0 | — | 0 | 1 | 1 | 1 | 3 | 5 | 7 | 11 | 15 | 19 | 30 | 43 |\n|  | 4/0 | — | 0 | 1 | 1 | 1 | 2 | 4 | 6 | 9 | 12 | 16 | 25 | 36 |\n|  | 250 | — | 0 | 0 | 1 | 1 | 1 | 3 | 5 | 7 | 10 | 13 | 20 | 29 |\n|  | 300 | — | 0 | 0 | 1 | 1 | 1 | 3 | 4 | 6 | 8 | 11 | 17 | 25 |\n|  | 350 | — | 0 | 0 | 1 | 1 | 1 | 2 | 3 | 5 | 7 | 10 | 15 | 22 |\n|  | 400 | — | 0 | 0 | 1 | 1 | 1 | 2 | 3 | 5 | 7 | 8 | 13 | 20 |\n|  | 500\u003Cbr>600 |  | 0 | 0 | 0 | 1 | 1 | 1 | 2 | 4 | 5 | 7 | 11 | 16 |\n|  |  | — | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 3 | 4 | 6 | 9 | 13 |\n|  | 700 | — | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 3 | 4 | 5 | 8 | 11 |\n|  | 750 | — | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 3 | 4 | 5 | 7 | 11 |\n|  | 800 | — | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 2 | 3 | 4 | 7 | 10 |\n|  | 900 | — | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 2 | 3 | 4 | 6 | 9 |\n|  | 1000 | — | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 3 | 4 | 6 | 8 |\n\nNotes: This table is for concentric stranded conductors only. For compact stranded conductors, Table C.8(A) should be used.  \nReproduced with permission of NFPA from NFPA 70®, National Electrical Code®, 2023 edition. Copyright© 2022, National Fire Protection Association. For a full copy of the NFPA 70®, please go[to www.nfpa.org](to www.nfpa.org).  \n[Gibsonstainless.com](Gibsonstainless.com)[ ](Gibsonstainless.com)[sales@gibsonstainless.com](sales@gibsonstainless.com)[ ](sales@gibsonstainless.com)800.945.4316","cbCaiidqnSJjjoQg","https://ap.wps.com/l/cbCaiidqnSJjjoQg","pdf",44014,"English","# Maximum Number of Conductors in Rigid Metal Conduit (RMC)\n## Conductor fill by trade size\n## Notes and NFPA 70 reproduction details","[{\"question\":\"What conduit type and installation scenario does this chart cover?\",\"answer\":\"The chart covers rigid metal conduit (RMC) and gives the maximum conductor fill for concentric stranded conductors.\"},{\"question\":\"Which conductor types are listed in the fill table?\",\"answer\":\"The table lists THHN, THWN, and THWN-2 conductor types.\"},{\"question\":\"Does the chart apply to compact stranded conductors?\",\"answer\":\"No. It states that for compact stranded conductors, Table C.8(A) should be used instead.\"}]","Maximum Number of Conductors in Rigid Metal Conduit (RMC) - Fill Chart | PDF",1790144440,[146],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3d494a1426ce3b59e9086c365247f30b.webp",983,1272]