[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-289226-105":59,"doc-detail-289226-en":135},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":128,"head_meta":130,"extra_data":132,"updated_unix":134},105,"en","matrixtm-direct-antiglobulin-test-card-ifu","MatrixTM Direct Antiglobulin Test Card - IFU","","MatrixTM Direct Antiglobulin Test Card instructions describe the purpose, principle, and performance of a Direct Antiglobulin Test (DAT) to detect red-cell coating in vivo with IgG, complement components (C3d), or both. The card differentiates IgG and/or C3d activity using a gel column format. The guide covers reagent contents, storage and stability conditions, required additional materials, sample collection and preparation, test procedure, and interpretation of positive, negative, mixed-field, and hemolysis reactions, plus control validation and safety notes.",{"@graph":69,"@context":127},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/matrixtm-direct-antiglobulin-test-card-ifu/289226/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/matrixtm-direct-antiglobulin-test-card-ifu/289226.png","ImageObject",300,407,{"name":92,"@type":93},"Hazel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-21","2026-09-17",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",13,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119,123],{"name":110,"@type":111,"acceptedAnswer":112},"What is the purpose of the MatrixTM Direct Antiglobulin Test Card?","Question",{"text":113,"@type":114},"It performs a Direct Antiglobulin Test (DAT) to determine whether red cells are coated in vivo with IgG, C3d, or both, and provides differentiation of IgG and/or C3d activity.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How should the card be stored and what is the stability guidance?",{"text":118,"@type":114},"Store the gel cards upright at 4–25°C and do not freeze. Avoid direct sunlight or heat sources, follow the expiry date on the label, and use immediately after removing the aluminium foil.",{"name":120,"@type":111,"acceptedAnswer":121},"How are DAT results interpreted with this gel card system?",{"text":122,"@type":114},"Positive reactions show agglutinated red cells forming a clear line at the top of the gel column or dispersed agglutinates in the gel. Negative reactions show non-agglutinated cells settling as a compact button at the bottom, with reaction strength graded from 4+ to ±; mixed-field patterns show both line formation and a compact button.",{"name":124,"@type":111,"acceptedAnswer":125},"What is required to validate the test results?",{"text":126,"@type":114},"The control microtube (Ctrl) must be negative to validate results; if it is not negative, wash the patient’s red blood cells with warm saline and repeat the test.","https://schema.org",{"og:url":83,"og:type":129,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":131,"canonical":83},"index,follow",{"doc_id":133,"site_id":62},289226,1789634780,{"code":4,"msg":5,"data":136},{"doc_id":133,"user_id":137,"nickname":92,"user_avatar":138,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":139,"file_id":140,"file_url":141,"file_type":142,"file_size":143,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":144,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":145,"faqs":146,"seo_title":147,"seo_description":67,"update_tm":134,"read_time":24,"preview_page_count":14,"preview_urls":148},137441390410,"https://ap-avatar.wpscdn.com/avatar/2000252f4ab5702993?_k=1776741390130283984","| \u003Cbr>+ 4 C0 \u003Cbr>\u003Cbr> + 25 C0 \u003Cbr>Store at 4-250C Consult Instructions for use \u003Cbr>Manufacturer IVD\u003Cbr>In vitro Diagnostic Medical Device LOT\u003Cbr>Batch Number / Lot Number \u003Cbr>This way up \u003Cbr>Expiry date \u003Cbr>Authorised Representative \u003Cbr>Date of Manufacture REF\u003Cbr>Catalogue Number PS\u003Cbr>Production Site DAT\u003Cbr>MatrixTM DAT Antiglobulin Test Card\u003Cbr>\u003Cbr>\u003Cbr> TULIP DIAGNOSTICS (P) LTD.\u003Cbr> PS\u003Cbr>\u003Cbr>10267/0 115/VER-04\u003Cbr>GITANJALI, TULIP BLOCK, DR. ANTONIO DO REGO BAGH, ALTO SANTACRUZ, BAMBOLIM COMPLEX P.O., GOA-403 202, [INDIA. Website: www.tulipgroup.com](INDIA. Website: www.tulipgroup.com)\u003Cbr>PLOT NOS. 92/96, PHASE II C, VERNA IND. EST. , VERNA, GOA-403 722, INDIA.\u003Cbr>EC REP\u003Cbr>Qarad b.v. b.a. Cipalstraat 3, B-2440 Geel, Belgium | \u003Cbr>\u003Cbr>REF 102670024 102670048 Pack Size 24 Cards 48 Cards\u003Cbr>MatrixTM Direct Antiglobulin Test Card\u003Cbr>SUMMARY\u003Cbr>A Direct Antiglobulin Test (DAT) is generally used to determine if the red cells have been coated in vivo with immunoglobulin (IgG), Components of complement (C3d) or both. Most DATs are initially performed with a polyspecific Anti-Human Globulin (AHG) reagent capable of detecting both IgG and C3d. If positive with polyspecific AHG, tests with monospecific anti-IgG and anti-complement reagents are recommended. These tests are useful in autoimmune hemolytic anemia, drug induced hemolytic anemia, hemolytic transfusion reactions and HDFN.\u003Cbr>MatrixTM Direct Antiglobulin Test Card gives DAT results with differentiation for IgG and or C3d activity.\u003Cbr>REAGENTS\u003Cbr>The MatrixTM Direct Antiglobulin Test Card contains six microtubes, prefilled with a gel in a suitable buffer containing goat polyclonal Anti-Human IgG and monoclonal Anti-C3d (Clone 12011D10)and neutral gel inappropriate microtubes.\u003Cbr>STORAGE AND STABILITY\u003Cbr>Store the MatrixTM gel cards in an upright position at 4-25°C. Do not freeze.\u003Cbr>Avoid exposure of MatrixTM gel cards to direct sunlight or any heat source. The shelf life of MatrixTM gel cards is as per the expiry date mentioned on the label. Do not use beyond expiry date. Once the aluminium foil is removed from the microtube, it should be used immediately.\u003Cbr>ADDITIONAL REAGENTSAND MATERIALS REQUIRED\u003Cbr>MatrixTM Diluent-2 LISS for preparation of red cell suspension (Refer package insert before use) . Gel card centrifuge (85g), Workstation, Micropipette capable of delivering 5-50ìlof specimen and Bottle top dispenser.\u003Cbr>PRINCIPLE\u003Cbr>As the MatrixTM gel card containing red blood cells is centrifuged under specific conditions, red blood cells possessing the corresponding antigen will agglutinate in presence of the specific antibody andwill be trapped inthe gel column. The red blood cells, which do not react are not trapped inthegel column and get settled atthe bottom of the microtube. The reactions are then read and graded according to their reactivity pattern.\u003Cbr>SAMPLE COLLECTION\u003Cbr>No special preparation of the patient is required prior to sample collection by approved techniques. For optimal results, freshly collected sample should be used. Anticoagulants like EDTA, CPD-A and Citrate can be used. Samples should be centrifugedat 1500g for 10 minutes to avoid fibrin residue which may interfere with results.\u003Cbr>SAMPLE PREPARATION\u003Cbr>Prepare a 0 .8% red blood cell suspension in MatrixTM Diluent-2 LISSas follows:\u003Cbr>1. Bring the MatrixTM Diluent-2 LISSto room temperature before testing.\u003Cbr>2. Dispense 1 ml of MatrixTM Diluent-2 LISS intoa clean test tube.\u003Cbr>3. Add 10ìlof packed red cells and mix gently.\u003Cbr>4. Red blood cell suspension so obtained should be used for testing.\u003Cbr>TEST PROCEDURE\u003Cbr>1. Label the first three microtubes of “MatrixTM Direct Antiglobulin Test Card” with patient’s name or identification number. Remove the aluminium foil carefully by pulling it backwards.\u003Cbr>2. Pipette 50ìl of 0 .8% patient’s red blood cell suspension to the labeled microtubes, taking care to ensure that micropipette tip does not touches the microtube.\u003Cbr>3. Centrifuge the cards for 10 m","cbCaikX4idUH3chK","https://ap.wps.com/l/cbCaikX4idUH3chK","pdf",37228,"English","# Summary\n# Reagents\n# Storage and Stability\n# Additional Reagents and Materials Required\n# Principle\n# Sample Collection\n# Sample Preparation\n# Test Procedure\n# Interpretation of Results\n# Note","[{\"question\":\"What is the purpose of the MatrixTM Direct Antiglobulin Test Card?\",\"answer\":\"It performs a Direct Antiglobulin Test (DAT) to determine whether red cells are coated in vivo with IgG, C3d, or both, and provides differentiation of IgG and/or C3d activity.\"},{\"question\":\"How should the card be stored and what is the stability guidance?\",\"answer\":\"Store the gel cards upright at 4–25°C and do not freeze. Avoid direct sunlight or heat sources, follow the expiry date on the label, and use immediately after removing the aluminium foil.\"},{\"question\":\"How are DAT results interpreted with this gel card system?\",\"answer\":\"Positive reactions show agglutinated red cells forming a clear line at the top of the gel column or dispersed agglutinates in the gel. Negative reactions show non-agglutinated cells settling as a compact button at the bottom, with reaction strength graded from 4+ to ±; mixed-field patterns show both line formation and a compact button. \"},{\"question\":\"What is required to validate the test results?\",\"answer\":\"The control microtube (Ctrl) must be negative to validate results; if it is not negative, wash the patient’s red blood cells with warm saline and repeat the test.\"}]","MatrixTM Direct Antiglobulin Test Card - IFU | PDF",[149,153],{"page_no":8,"url":150,"width":151,"height":152},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/25846dd8c4f8bd94b716b7c60f8b85a4.webp",983,759,{"page_no":14,"url":154,"width":155,"height":156},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/247891636952134605dcc6d0ab0e2901.webp",982,758]