[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-651155-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-651155-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","mat-slab-bending-details-raft-slab-reinforcement-details","MAT SLAB - Bending Details - Raft Slab Reinforcement Details","","This drawing sheet provides bending and reinforcement placement details for a mat slab and raft slab foundation. It includes bar mark tables with quantities, bar sizes, total lengths, and types, along with structural notes specifying clear cover requirements and lap schedules. Material specifications reference ASTM A615, Grade 60 black steel, and provide legend definitions for top/bottom, elevations, clear cover, typical thickness, and long/short way labeling. It references raft slab placing details with drawing numbers R-1 and R-2.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/mat-slab-bending-details-raft-slab-reinforcement-details/651155/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/mat-slab-bending-details-raft-slab-reinforcement-details/651155.png","ImageObject",300,407,{"name":42,"@type":43},"Jordan Avery","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":22},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What material standard and grade are specified for the reinforcement?","Question",{"text":62,"@type":63},"All material on the drawing is specified as ASTM A615, Grade 60 black U.N.O.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What information is listed in the bar mark table?",{"text":67,"@type":63},"The table lists bar mark, quantity, size, total length, type, and multiple dimensional markers (A', B', C, D', etc.) for bending layout.",{"name":69,"@type":60,"acceptedAnswer":70},"How is lap length scheduled for the bars?",{"text":71,"@type":63},"The drawing includes a lap schedule stating LAP = 36 BAR DIA and provides related lap and length details under bar dia entries.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},651155,1792866190,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":96},1099523882367,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","| BENDING DETAILS  \u003Cbr>Drawing Sheet:R-1   |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Bar Mark   | Qty   | Size   | Total Length   | Type   | A'   | ’B'   | 'C   | ’D'   | E'   | F'   | 'G'   | H'   | J   | K'   | ’0   | ’R'   |\n| 4A05   | 745   | \\#4   | 6'-3”   | 25   |  | 1'-6”   | 1'-3 Y”   | 0′-8”   | 1'-3Y”   | 1'-6”   |  | 1'-3”   |  | 0'-7x”   |  |  |\n| 7A01   | 86   | \\#7   | 7'-11”   | 3   |  | 1'-2”   | 4'-1”   | 2'-8”   |  |  |  | 2'-114”   |  | 2'-10”   | 6'-8”   |  |\n| 7A04   | 44   | \\#7   | 8'-7 k”   | 3   |  | 1'-2”   | 4'-9Y”   | 2'-8”   |  |  |  | 3'-54”   |  | 3'-4”   | 7'-2”   |  |\n\n\n| STRUCTURAL NOTES   |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| CLEAR COVER TO REINFORCEMENT   |  |  |  |  |  |  | FOR MAT FOUNDATION   |  |  |\n| REFT SLAB   |  |  | 3\"   | BOTTOM4 SIDES   |  |  |  |  |  |\n|  |  |  |  |  |  |  | LAP SCHEDULE  \u003Cbr>(LAP=36 BAR DIA)   |  |  |\n| REFT SLAB   |  |  | 2\"   | TOP   |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |\n|  | ALL MATERIAL ON THIS DRAWING  \u003Cbr>ASTM A615  \u003Cbr>GRADE 60 BLACK U.N.O   |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  | BAR DIA.   | LAP   | LD   |\n|  |  |  |  |  |  |  | \\#7   | 2'-8\"   | 2'-I\"   |\n|  |  |  |  |  |  |  |  |  |  |\n| LEGENDS   |  |  |  |  | LABEL LEGENDS   |  |  |  |  |\n| T  \u003Cbr>-TOP  \u003Cbr>B  \u003Cbr>-BOTTOM  \u003Cbr>EL.  \u003Cbr>-ELEVATION  \u003Cbr>CLR  \u003Cbr>-CLEAR COVER  \u003Cbr>TYP.  \u003Cbr>-TYPICAL  \u003Cbr>T.0.5  \u003Cbr>-TOP OF SLAB  \u003Cbr>LW  \u003Cbr>-LONG WAY  \u003Cbr>SW  \u003Cbr>-SHORT WAY  \u003Cbr>THK.    -THICKNESS   |  |  |  |  | 6×2×6\\#44CO9 @l2\"B2  \u003Cbr>NOTES  \u003Cbr>SPACING  \u003Cbr>BAR MARK  \u003Cbr>—BAR SIZE  \u003Cbr>—  NUMBER OF BARS  \u003Cbr>——EACH FACE/EACH SIDE  \u003Cbr>——NUMBER OF LOCATION   |  |  |  |  |\n|  |  |  |  |  | [EL.X'-X×\"]     DENOTES TOP ELEVATIONS   |  |  |  |  |\n| RAFT SLAB-PLACING DRAWING REFERENCE   |  |  |  |  |  |  |  |  |  |\n| DWG.NO:   |  | DRAWING DESCRIPTION   |  |  |  |  |  |  |  |\n| R-l   |  | RAFT SLAB BOTTOM REINF.DETAILS   |  |  |  |  |  |  |  |\n| R-2   |  | RAFT SLAB TOP REINF.DETAILS   |  |  |  |  |  |  |  |\n\n| Drawing Sheet:R-2  \u003Cbr>BENDING DETAILS   |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Bar Mark   | Qty   | Size   | Total Length   | Type   | A'   | 'B'   | C   | ’D'   | E'   | F'   | ’G'   | 'H   | J   | K'   | ’0'   | ’R'   |\n| 7A02   | 96   | \\#7   | 6'-9”   | 20   |  | 1'-2”   | 2'-11”   | 2'-8”   |  |  |  |  |  |  |  |  |\n| 7A03   | 62   | \\#7   | 7'-3”   | 20   |  | 1'-2”   | 3'-5”   | 2'-8”   |  |  |  |  |  |  |  |  |\n\nB  \nC  \nD  \n20  \n\n| STRUCTURAL NOTES   |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| CLEAR COVER TO REINFORCEMENT   |  |  |  |  | FOR MAT FOUNDATION   |  |  |\n| REFT SLAB   |  | 3\"   | BOTTOM 4SIDES   |  |  |  |  |\n|  |  |  |  |  | LAP SCHEDULE  \u003Cbr>(LAP=36 BAR DIA)   |  |  |\n| REFT SLAB   |  | 2\"   | TOP   |  |  |  |  |\n|  |  |  |  |  |  |  |  |\n|  |  |  |  |  | BAR DIA.   | LAP   | LD   |\n|  |  |  |  |  | \\#7   | 2'-8\"   | 2'-I\"   |\n| LEGENDS   |  |  |  | LABEL LEGENDS   |  |  |  |\n| T -TOP  \u003Cbr>-BOTTOM  \u003Cbr>B  \u003Cbr>-ELEVATION  \u003Cbr>EL.  \u003Cbr>-CLEAR COVER  \u003Cbr>CLR  \u003Cbr>-TYPICAL  \u003Cbr>TYP.  \u003Cbr>-TOP OF SLAB  \u003Cbr>T.O.S  \u003Cbr>-LONG WAY  \u003Cbr>LW  \u003Cbr>-SHORT WAY  \u003Cbr>SW  \u003Cbr>THK.     -THICKNESS   |  |  |  | 6×2×6 \\#44C09 @l2\"B2  \u003Cbr>NOTES  \u003Cbr>SPACING  \u003Cbr>BAR MARK  \u003Cbr>BAR SIZE  \u003Cbr>NUMBER OF BARS  \u003Cbr>EACH FACE/EACH SIDE  \u003Cbr>NUMBER OF LOCATION   |  |  |  |\n|  |  |  |  | [EL.X'-X×\"]    DENOTES TOP ELEVATIONS   |  |  |  |\n| RAFT SLAB-PLACING DRAWING REFERENCE   |  |  |  |  |  |  |  |\n| DWG.NO:   | DRAWING DESCRIPTION   |  |  |  |  |  |  |\n| R-l   | RAFT SLAB BOTTOM REINF.DETAILS   |  |  |  |  |  |  |\n| R-2   | RAFT SLAB TOP REINF.DETAILS   |  |  |  |  |  |  |\n\n\n| ALL MATERIAL ON THIS DRAWING  \u003Cbr>ASTM A615  \u003Cbr>GRADE 60 BLACK U.N.O   |\n| --- |\n\nSECTION①  \nSEC","cbCaihtElijc78lL","https://ap.wps.com/l/cbCaihtElijc78lL","pdf",291245,"English","# BENDING DETAILS\n## Drawing Sheet R-1\n## Drawing Sheet R-2\n# STRUCTURAL NOTES AND LEGENDS\n## Material and specification notes\n## Lap schedule and clear cover\n# RAFT SLAB-PLACING DRAWING REFERENCE\n## DWG R-1 and R-2","[{\"question\":\"What material standard and grade are specified for the reinforcement?\",\"answer\":\"All material on the drawing is specified as ASTM A615, Grade 60 black U.N.O.\"},{\"question\":\"What information is listed in the bar mark table?\",\"answer\":\"The table lists bar mark, quantity, size, total length, type, and multiple dimensional markers (A', B', C, D', etc.) for bending layout.\"},{\"question\":\"How is lap length scheduled for the bars?\",\"answer\":\"The drawing includes a lap schedule stating LAP = 36 BAR DIA and provides related lap and length details under bar dia entries.\"}]","MAT SLAB - Bending Details - Raft Slab Reinforcement Details | PDF"]