[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-664430-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-664430-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","manual-no-71201-installation-operation-and-maintenance-manual-agitators-model-20-gta-gtl-gtnt-20-hta-htl-htnt","Manual No. 712.01 - Installation, Operation and Maintenance Manual - Agitators Model 20 GTA, GTL, GTNT, 20 HTA, HTL, HTNT","","Installation, Operation and Maintenance Manual No. 712.01 provides service guidance for Chemineer agitator models 20 GTA, GTL, GTNT and 20 HTA, HTL, HTNT, including case sizes 21–23. The manual covers product nomenclature, initial inspection, safety requirements and checklists, storage practices, vessel mounting and agitator load descriptions, and detailed installation procedures for seals, couplings, gear drive, shafts, handhole covers, and motor. It also addresses impellers, options, lubrication schedules, and operation instructions.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/manual-no-71201-installation-operation-and-maintenance-manual-agitators-model-20-gta-gtl-gtnt-20-hta-htl-htnt/664430/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/manual-no-71201-installation-operation-and-maintenance-manual-agitators-model-20-gta-gtl-gtnt-20-hta-htl-htnt/664430.png","ImageObject",300,407,{"name":42,"@type":43},"Terk","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"Which agitator models are covered by Manual No. 712.01?","Question",{"text":62,"@type":63},"The manual covers Chemineer agitator models 20 GTA, GTL, GTNT, and 20 HTA, HTL, HTNT, for case sizes 21, 22, and 23.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What safety topics and checklist items are included?",{"text":67,"@type":63},"The safety section includes vessels, fasteners, CE marking (where applicable), and a safety checklist to guide safe handling and installation.",{"name":69,"@type":60,"acceptedAnswer":70},"What maintenance areas does the manual address after installation?",{"text":71,"@type":63},"After installation, it provides guidance on impellers, options, lubrication (motor, gear drive, shaft seals, steady bearings), and operation procedures such as agitator operation.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},664430,1793254663,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":7,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":143},1099525198933,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Manual No. 712.01  \nInstallation, Operation and Maintenance Manual Model 20 GTA, GTL, GTNT Agitators  \nModel 20 HTA, HTL, HTNT Agitators  \n(Case Size 21, 22, 23)  \nEquipment Reference:  \nFor service and information contact:  \nChemineer, Inc. 5870 Poe Ave, Dayton, OH 45414  \nToll Free: 1 (800) 643-0641  \nPhone: 1 (937) 454 3200  \nFax: 1 (937) 454 3379  \nE-mail: [reachus.chemineerus@robn.com](reachus.chemineerus@robn.com)  \n[techsales.chemineerus@robn.com](techsales.chemineerus@robn.com)[ ](techsales.chemineerus@robn.com)[parts.chemineerus@robn.com](parts.chemineerus@robn.com)  \n[Web:](Web: www.chemineer.com)[ www.chemineer.com](Web: www.chemineer.com)  \nChemineer  \n7 Cranmer Road West Meadows Derby, UK  \nDE21 6XT  \nPhone: +44 (0) 1332 363175  \nFax: +44 (0) 1332 290323  \nE-mail: [sales.chemineeruk@robn.co.uk](sales.chemineeruk@robn.co.uk)  \n[parts.chemineeruk@robn.co.uk](parts.chemineeruk@robn.co.uk)  \n[Web:](Web: www.chemineer.com)[ www.chemineer.com](Web: www.chemineer.com)  \nTABLE OF CONTENTS  \nA. PRODUCT NOMENCLATURE ....................................................................... 1  \nB. INITIAL INSPECTION .....................................................................................2  \nC. CHEMINEER ASSISTANCE ...........................................................................3  \nD. SAFETY ...............................................................................................................4  \nD.1 VESSELS ...................................................................................................................................................4  \nD.2 FASTENERS..............................................................................................................................................4  \nD.3 CE MARKING (WHERE APPLICABLE) ...............................................................................................4  \nD.4 SAFETY CHECKLIST .............................................................................................................................. 5  \nE. STORAGE ........................................................................................................... 6  \nE.1 SHORT-TERM INDOOR STORAGE .......................................................................................................6  \nE.2 OUTDOOR OR LONG-TERM INDOOR STORAGE ..............................................................................6  \nE.3 CUSTOMER RESPONSIBILITY.............................................................................................................. 8  \nF. VESSEL MOUNTING ..................................................................................... 10  \nF.1 DESCRIPTION OF AGITATOR LOADS............................................................................................... 10  \nG. AGITATOR INSTALLATION ....................................................................... 16  \nH. SEAL INSTALLATION -STUFFING BOX ................................................ 19  \nH.1 BOLT-IN STUFFING BOX DESIGN (CAST HOUSING)..................................................................... 19  \nH.2 BOLT-IN STUFFING BOX DESIGN (FABRICATED HOUSING) ......................................................21  \nI. SEAL INSTALLATION -LIP SEAL ............................................................23  \nJ. SEAL INSTALLATION -SPLIT SEAL .......................................................24  \nK. TAPER BORE COUPLING AND GEAR DRIVE INSTALLATION ........26  \nK.1 SHAFT TAPER COUPLING INSTALLATION .....................................................................................26  \nK.2 GEARBOX INSTALLATION .................................................................................................................27  \nL. SHAFT RUNOUT .............................................................................................28  \nM. HANDHOLE COVER INSTALLATION ......................................................29  \nN. MOTOR INSTALLATION .","cbCaijIKFPHT0yOi","https://ap.wps.com/l/cbCaijIKFPHT0yOi","pdf",3188355,"English","# A. PRODUCT NOMENCLATURE\n# B. INITIAL INSPECTION\n# C. CHEMINEER ASSISTANCE\n# D. SAFETY\n## D.1 VESSELS\n## D.2 FASTENERS\n## D.3 CE MARKING (WHERE APPLICABLE)\n## D.4 SAFETY CHECKLIST\n# E. STORAGE\n## E.1 SHORT-TERM INDOOR STORAGE\n## E.2 OUTDOOR OR LONG-TERM INDOOR STORAGE\n## E.3 CUSTOMER RESPONSIBILITY\n# F. VESSEL MOUNTING\n## F.1 DESCRIPTION OF AGITATOR LOADS\n# G. AGITATOR INSTALLATION\n# H. SEAL INSTALLATION -STUFFING BOX\n## H.1 BOLT-IN STUFFING BOX DESIGN (CAST HOUSING)\n## H.2 BOLT-IN STUFFING BOX DESIGN (FABRICATED HOUSING)\n# I. SEAL INSTALLATION -LIP SEAL\n# J. SEAL INSTALLATION -SPLIT SEAL\n# K. TAPER BORE COUPLING AND GEAR DRIVE INSTALLATION\n## K.1 SHAFT TAPER COUPLING INSTALLATION\n## K.2 GEARBOX INSTALLATION\n# L. SHAFT RUNOUT\n# M. HANDHOLE COVER INSTALLATION\n# N. MOTOR INSTALLATION\n# O. IMPELLERS\n## O.1 MATCH-MARKING\n## O.2 IMPELLERS-INSTALLATION\n## O.3 IMPELLERS – STYLES\n## O.4 IMPELLERS – COATED / RUBBER COVERED\n# P. OPTIONS\n## P.1 IN-TANK COUPLING\n## P.2 STEADY BEARINGS\n# Q. LUBRICATION\n## Q.1 MOTOR-LUBRICATION\n## Q.2 GEAR DRIVE-LUBRICATION\n## Q.3 SHAFT SEALS-LUBRICATION\n## Q.4 STEADY BEARINGS-LUBRICATION\n# R. OPERATION\n## R.1 AGITATOR OPERATION","[{\"question\":\"Which agitator models are covered by Manual No. 712.01?\",\"answer\":\"The manual covers Chemineer agitator models 20 GTA, GTL, GTNT, and 20 HTA, HTL, HTNT, for case sizes 21, 22, and 23.\"},{\"question\":\"What safety topics and checklist items are included?\",\"answer\":\"The safety section includes vessels, fasteners, CE marking (where applicable), and a safety checklist to guide safe handling and installation.\"},{\"question\":\"What maintenance areas does the manual address after installation?\",\"answer\":\"After installation, it provides guidance on impellers, options, lubrication (motor, gear drive, shaft seals, steady bearings), and operation procedures such as agitator operation.\"}]","Manual No. 712.01 - Installation, Operation and Maintenance Manual - Agitators Model 20 GTA, GTL, GTNT, 20 HTA, HTL, HTNT | PDF",265]