[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-464293-105":59,"doc-detail-464293-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","magnetic-circuit-design-and-optimization-of-tension-compression-giant-magnetostrictive-force-sensor","Magnetic Circuit Design and Optimization of Tension-Compression Giant Magnetostrictive Force Sensor","","Helicopter variable-pitch connecting rods experience axial tensile and compressive loads that must be monitored reliably during operation. Traditional strain-gauge sensing is vulnerable to external conditions, motivating a giant magnetostrictive (GM) tension–compression force sensor with a permanent-magnet bias that is systematically optimized. The work builds a magnetic-circuit mathematical model, simulates and analyzes multiple circuit configurations, evaluates performance via magnetic-flux uniformity, and studies the effects of material and structural parameters using orthogonal tests. Results show improved flux guidance without magnetic side walls and enhanced uniformity by 7.44%, higher flux density by 13.9 mT, and linear Hall output-voltage increase of 1.125%.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/magnetic-circuit-design-and-optimization-of-tension-compression-giant-magnetostrictive-force-sensor/464293/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/magnetic-circuit-design-and-optimization-of-tension-compression-giant-magnetostrictive-force-sensor/464293.png","ImageObject",300,407,{"name":92,"@type":93},"pixelkiddo","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-19","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why is strain-gauge based load monitoring challenging for helicopter rotor systems?","Question",{"text":112,"@type":113},"Strain gauges require extensive installation on rotor surfaces, which can alter the blade aerodynamic shape and affect aerodynamic efficiency and aeroelastic response characteristics.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What sensor solution is proposed in this study?",{"text":117,"@type":113},"A giant magnetostrictive (GM) tension–compression force sensor is proposed with permanent-magnet bias to provide a stable magnetic bias without additional power supply.",{"name":119,"@type":110,"acceptedAnswer":120},"How are magnetic circuit parameters optimized and evaluated?",{"text":121,"@type":113},"A magnetic-circuit mathematical model is established and various circuit configurations are simulated. Magnetic-flux uniformity is used as the evaluation index, relative permeability of magnetic material and structure are studied, and the optimal parameter combination is determined using orthogonal tests.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},464293,1791072270,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962090883892,"https://ap-avatar.wpscdn.com/avatar/e00115db34f3e0f11b?x-image-process=image/resize,m_fixed,w_180,h_180&k=1790152879550218658","Article  \nMagnetic Circuit Design and Optimization of  \nTension–Compression Giant Magnetostrictive Force Sensor  \nLong Li 1, Hailong Sun 2, Yingling Wei 3, Boda Li 4, Hongwei Cui 2,* and Ruifeng Liu 1  \nAcademic Editor: EwaKorzeniewska  \nReceived: 18 October 2025  \nRevised: 8 November 2025  \nAccepted: 25 November 2025  \nPublished: 2 January 2026  \nCopyright: © 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 College of Aeronautics and Astronautics, Taiyuan University of Technology, Taiyuan 030024, China; [lilong01@tyut.edu.cn](lilong01@tyut.edu.cn) (L.L.)  \n2 College of Mechanical Engineering, Taiyuan University of Technology, Taiyuan 030024, China  \n3 College of Chemistry and Chemical Engineering, Taiyuan University of Technology, Taiyuan 030024, China  \n4 College of Civil Engineering, Taiyuan University of Technology, Taiyuan 030024, China  \n* Correspondence: [cuihongwei@tyut.edu.cn](cuihongwei@tyut.edu.cn)  \nAbstract  \nThe variable-pitch connecting rod of a helicopter bears axial tensile and compressive loads during operation. The traditional load monitoring method using strain gauge is easily affected by external conditions. Therefore, a giant magnetostrictive (GM) tension and compression force sensor with permanent magnet bias is proposed and optimized. Because the bias magnetic field plays a decisive role in the performance of the sensor, this paper has carried out in-depth research on this. Firstly, the mathematical model of the magnetic circuit is established, and the various magnetic circuits of the sensor are simulated and analyzed. Secondly, the magnetic flux uniformity of the GMM rod is used as the evaluation index, and the relative permeability of the magnetic material and the structure are systematically studied. The influence of parameters on the magnetic flux of the magnetic circuit, and finally the optimal parameter combination of the magnetic circuit is determined by orthogonal test. The results show that when the magnetic circuit without the magnetic side wall is used, the magnetic material can better guide the magnetic flux through the GMM rod; the magnetic flux uniformity of the optimized GMM force sensor is increased by 7.44%, the magnetic flux density is increased by 13.9 mT and the Hall output voltage increases linearly by 1.125% in the same proportion. This provides an important reference for improving the utilization rate of GMM rods and also improves the safety of flight operation and reduces maintenance costs.  \nKeywords: giant magnetostrictive force sensor; magnetic conductive materials; magnetic circuit; uniformity; COMSOL finite element simulation  \n1. Introduction  \nHelicopter rotor load monitoring is an important way to improve the safety and reliability of aircraft operation. The traditional load monitoring method uses strain gauges. The rotor surface needs to paste a large number of strain gauges. A large number of strain gauges will change the aerodynamic shape of the rotor blades and affect the aerodynamic efficiency and aeroelastic response characteristics of the rotor [1] . With the continuous progress and innovation of technology, it is necessary to promote new load monitoring methods in a timely manner.  \nGiant magnetostrictive material is a new type of intelligent material with high Curie temperature, high magneto mechanical coupling coefficient, good frequency response characteristics and large magnetostrictive strain, which makes it widely studied in the  \nfields of energy conversion, micro drive, fluid machinery, precision machining, linear motor, vibration control, ultrasonic and so on [2–5] . Yan and Yang gave the design principle of the giant magnetostrictive force sensor based on the analysis of the magnetostrictive inverse effect and designed the structure of the giant magnetostrictive force sensor [6] . Liu developed a giant magnetos","cbCaidGoYLSfdKU0","https://ap.wps.com/l/cbCaidGoYLSfdKU0","pdf",6943513,22,"English","# Introduction\n## Existing load monitoring methods\n## Prior research on magnetostrictive force sensors and magnetic circuits\n## Bias magnetic field approaches","[{\"question\":\"Why is strain-gauge based load monitoring challenging for helicopter rotor systems?\",\"answer\":\"Strain gauges require extensive installation on rotor surfaces, which can alter the blade aerodynamic shape and affect aerodynamic efficiency and aeroelastic response characteristics.\"},{\"question\":\"What sensor solution is proposed in this study?\",\"answer\":\"A giant magnetostrictive (GM) tension–compression force sensor is proposed with permanent-magnet bias to provide a stable magnetic bias without additional power supply.\"},{\"question\":\"How are magnetic circuit parameters optimized and evaluated?\",\"answer\":\"A magnetic-circuit mathematical model is established and various circuit configurations are simulated. Magnetic-flux uniformity is used as the evaluation index, relative permeability of magnetic material and structure are studied, and the optimal parameter combination is determined using orthogonal tests.\"}]","Magnetic Circuit Design and Optimization of Tension-Compression Giant Magnetostrictive Force Sensor | PDF",1790767998,55,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d3d088c58ae39962c4a35c4c4128c4fb.webp",983,1390,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/32c7970782a68a43dc9e06895e531efc.webp",982,1388,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/bae17b3cc18c86f48b1bf71bb3aa4c82.webp",981,1387,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/35a057d24fbc49b6ab08265022a2d9b3.webp",980,1385]