[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-663257-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-663257-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","machine-room-less-elevator-in-compliance-with-en81-20-and-en81-50","Machine-Room-Less Elevator - In Compliance With EN81-20 and EN81-50","","Machine-room-less elevator concept document for the REXIA brand, presenting a product framework that complies with EN81-20 and EN81-50. It details component integration and quality management under Fujitec’s “Global Common Components,” emphasizing safety, reliability, ecology, and comfort. Safety measures include EZSHUTTLE-based destination guidance, night-time self-checking, multi-beam door sensing, and protections such as ACOP and UCMP, alongside reinforced landing and car doors.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/machine-room-less-elevator-in-compliance-with-en81-20-and-en81-50/663257/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/machine-room-less-elevator-in-compliance-with-en81-20-and-en81-50/663257.png","ImageObject",300,407,{"name":42,"@type":43},"Indoniesian Boy","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":30},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What standards are REXIA machine-room-less elevators designed to comply with?","Question",{"text":62,"@type":63},"REXIA elevators are designed to comply with EN81-20 and EN81-50.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"How does the EZSHUTTLE destination floor guidance system reduce passenger travel time?",{"text":67,"@type":63},"Passengers register destinations at elevator floors, and the system assigns the most suitable elevators to minimize destination stops, reducing riding time by 50% at peak periods.",{"name":69,"@type":60,"acceptedAnswer":70},"What safety functions are included to improve reliability in REXIA elevators?",{"text":71,"@type":63},"Night-time self-checking automatically checks mechanical brake conditions, and the multi-beam sensor interrupts the closing doors and reopens them when beams are blocked.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},663257,1793226075,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":30,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":79,"read_time":144},962090760608,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Machine-Room-Less Elevator  \nIn Compliance With the Standards of EN81-20 and EN81-50  \nProduct Concept  \nBy manufacturing safe and reliable elevators,  \nwe are building trust with people around the world.  \nFujitec’s “Global Common Components” are used in the REXIA brand. The quality of components, such  \nas traction machines, elevator controllers, and operating xtures, is controlled through Fujitec’s integrated system of global quality management. Elevators with the same high quality will be provided by Fujitec’s global production base under the concept of “Made in Fujitec”.  \n“Made in Fuji tec”  \nBy providing people with the safe and reliable elevators that  \nFujitec manufactures in-house, Fujitec is building trust with  \npeople around in the world.  \n70-Year History in the Business of Elevator, Escalator and Moving Walks  \nSince the foundation of Fujitec in 1948, seeing the market from a global perspective and having the spirit of being a top global company, Fujitec has been a global leading manufacturer of elevators, escalators, and moving walks. Fujitec has been providing the people with leading-edge technologies and global standards of product.  \n2  \nProduct Concept  \nSafety & Reliability  \n\n| All control-related components ranging from control circuits to inverters are independently developed by Fujitec, so that highly reliable elevator operation is established. When the elevator control system assembled with Fujitec’s reliable component parts detects the possibility of the occurrence of elevator malfunction, it operates in order to maintain the elevator operation stable and ef cient.\u003Cbr>Ecology | |\n| --- | --- |\n| In REXIA elevators, the gearless traction machines with a permanent magnetic synchronous motor assure low power consumption. Also, the electric power regenerative unit equipped between the elevator controller and the power supply saves the electrical energy consumption in the building. Fujitec contributes to global society by providing for ecology-conscious products, re􀀞ecting on them 70 years of knowledge and technologies accumulated through the manufacturing of elevators.\u003Cbr>Comfort Design | |\n\nUnder Fujitec’s universal designs, newly adopted buttons for elevator operating xtures are highly visible and tactually recognizable, and the numbers and letters shown on aesthetically re ned displays can be easily seen and read.  \nAlso, various styles for the decoration of elevator interior and landing 􀀞oors provide the passengers with a superb and comfortable riding experience.  \nNote: Application of capacity and speed may differ due to speci cation.  \nContents  \nSafety & Reliability  5   Ecology  9  Comfort Design  11  Car Design  13  Color and Pattern Variations  21  Ceiling Design  23  Options  24   Entrance Design  25   EN81-70 Requirements  26  Car Operating Boards  27   Hall Fixtures  29  Speci cation Details  31   Planning  36  Standard Dimensions  41   Power Supply Data  45  Work by Others  46  Global Operations  47   \nSafety & Reliability  \n-Destination Floor Guidance System-  \n Elevator Operating System with EZSHUTTLE  Low Zone  Mid Zone   High Zone    \nGSC System  \n* Based on comparisons of passenger riding time obtained under a conventional elevator operating system and that under a simulated EZSHUTTLE-equipped elevator operating system.  \nPassengers are waiting in front of the elevators indicated on the entry terminals.  \nBefore Elevator’s Arrival  \nEach group of passengers can ride in the elevator bound for its destination.  \nAt the Time of Passengers’ Riding  \nIn an elevator operating system with EZSHUTTLE, passengers are required to register their destinations at the elevator oors rather than conventionally registering them inside the elevator. The EZSHUTTLE system then guides passengers to their assigned elevators, which will have been selected to minimize the number of destination stops based on the registered destinations.  \nThis passenger guidance and elevator assignment provides passengers with","cbCaivH9ND3RNIwd","https://ap.wps.com/l/cbCaivH9ND3RNIwd","pdf",9685346,27,"English","# Safety & Reliability\n## -Destination Floor Guidance System-\n## -Safety enhancement for increased reliability-\n# Ecology\n# Comfort Design\n# Car Design\n# Color and Pattern Variations\n# Ceiling Design\n# Options\n# Entrance Design\n# EN81-70 Requirements\n# Car Operating Boards\n# Hall Fixtures\n# Speciﬁcation Details\n# Planning\n# Standard Dimensions\n# Power Supply Data\n# Work by Others\n# Global Operations","[{\"question\":\"What standards are REXIA machine-room-less elevators designed to comply with?\",\"answer\":\"REXIA elevators are designed to comply with EN81-20 and EN81-50.\"},{\"question\":\"How does the EZSHUTTLE destination floor guidance system reduce passenger travel time?\",\"answer\":\"Passengers register destinations at elevator floors, and the system assigns the most suitable elevators to minimize destination stops, reducing riding time by 50% at peak periods.\"},{\"question\":\"What safety functions are included to improve reliability in REXIA elevators?\",\"answer\":\"Night-time self-checking automatically checks mechanical brake conditions, and the multi-beam sensor interrupts the closing doors and reopens them when beams are blocked.\"}]","Machine-Room-Less Elevator - In Compliance With EN81-20 and EN81-50 | PDF",68]