[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-181155-105":59,"doc-detail-181155-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","ma3-n-data-sheet-load-speed-and-output-signal-specifications","MA3-N - Data Sheet - Load, Speed, and Output Signal Specifications","","MA3-N actuator configuration data provides drawing dimensions, retractable length, and duty-cycle performance for multiple screw types (ACME screw and ballscrew) under defined motor speeds and DC voltage options. The sheet maps actuator load (N), maximum stroke, and retracted length by code groups, then details attachments (front/rear), direction of rear attachment, and limit-switch behavior at EOS. It specifies external actuator signals, output signal types (mechanical potentiometer, NPN/PNP hall sensors, T-Smart PCBA input), IP ratings, wiring and connector options, and alternative communication interfaces like SAE J1939 and Modbus, plus signal/load adjustment tables.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ma3-n-data-sheet-load-speed-and-output-signal-specifications/181155/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ma3-n-data-sheet-load-speed-and-output-signal-specifications/181155.png","ImageObject",300,407,{"name":92,"@type":93},"Jordan Avery","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-17","2026-09-02",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",13,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What information does the MA3-N data sheet include for actuator performance?","Question",{"text":113,"@type":114},"It includes load (N), motor speed, duty cycle, typical current, and typical speed for different screw types and code groups, along with corresponding maximum stroke values.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How are limit switch behaviors at EOS defined?",{"text":118,"@type":114},"The sheet provides multiple function options describing whether limit switches cut off the actuator at EOS or send signals at EOS, including signal types such as normally open or normally closed depending on the selected option code.",{"name":120,"@type":111,"acceptedAnswer":121},"Which output signal and external signal types are supported?",{"text":122,"@type":114},"Output signal options include no output, mechanical potentiometer, and hall sensors (NPN/PNP), and there are external signal options such as reed switch variants. It also lists an option for hall sensor input to a T-Smart PCBA.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},181155,1788343603,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":130,"read_time":144},1099523882367,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","| Drawing\u003Cbr>Standard Dimensions (mm)\u003Cbr>35.1 229.1\u003Cbr>250.1 |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| \u003Cbr>12.9\u003Cbr>19.5 |  |  |  | ∅12.8\u003Cbr>1315.9 |  |  |  |  | 34.1\u003Cbr>146.4 |  |\n| Retracted Length\u003Cbr>52 ∅34\u003Cbr>∅25.4 76 |  |  |  |  |  |  |  |  |  |  |\n| Load and Speed |  |  |  |  |  |  |  |  |  |  |\n| Spindle Type | CODE Load (N)\u003Cbr>Push Pull |  |  | Self Locking Force (N)\u003Cbr>Mechenical Brake | Duty Cycle | Typical Current (A)\u003Cbr>No Load With Load\u003Cbr>24VDC 24VDC |  | Typical Speed (mm/s)\u003Cbr>No Load With Load\u003Cbr>24VDC 24VDC |  |  |\n| ACME | Motor Speed (5100RPM)\u003Cbr>F 500 500 |  |  | 650 | 25% | 2.5 | 10.2 | 172.5 |  | 152.0 |\n| screw | K\u003Cbr>G\u003Cbr>H\u003Cbr>M\u003Cbr>N\u003Cbr>J | 1000\u003Cbr>2500\u003Cbr>5000\u003Cbr>7500\u003Cbr>10000\u003Cbr>16000 | 1000\u003Cbr>2500\u003Cbr>5000\u003Cbr>7500\u003Cbr>10000\u003Cbr>16000 | 1300\u003Cbr>3250\u003Cbr>6500\u003Cbr>9750\u003Cbr>13000\u003Cbr>20800 | 25%\u003Cbr>25%\u003Cbr>25%\u003Cbr>25%\u003Cbr>25%\u003Cbr>15% | 2.5\u003Cbr>2.5\u003Cbr>2.5\u003Cbr>2.5\u003Cbr>2.5\u003Cbr>2.5 | 10.2\u003Cbr>10.5\u003Cbr>10.2\u003Cbr>11.4\u003Cbr>11.3\u003Cbr>12.6 | 86.0\u003Cbr>43.0\u003Cbr>21.5\u003Cbr>14.0\u003Cbr>10.5\u003Cbr>7.2 |  | 76.0\u003Cbr>38.0\u003Cbr>19.0\u003Cbr>12.4\u003Cbr>9.3\u003Cbr>6.2 |\n| Ballscrew | P\u003Cbr>Q | 7500\u003Cbr>10000 | 7500\u003Cbr>10000 | 9750\u003Cbr>13000 | 25%\u003Cbr>25% | 3.0\u003Cbr>3.0 | 12.0\u003Cbr>10.5 | 21.3\u003Cbr>14.2 |  | 18.2\u003Cbr>12.5 |\n|  | R | 16000 | 16000 | 20800 | 15% | 3.0 | 13.0 | 10.6 |  | 8.9 |\n\n| CODE | Load (N) | Max Stroke (mm) |\n| --- | --- | --- |\n| F, K, G | ≤ 2500 | 1000 |\n| H | ≤ 5000 | 800 |\n| M, N, P, Q | ≤ 10000 | 600 |\n| J, R | ≤ 16000 | 400 |\n\n| Type | N = Normal |  |  | T = T-Smart |  |\n| --- | --- | --- | --- | --- | --- |\n| Voltage | 1 = 12V DC 2 = 24V DC |  |  | 6 = 12V DC, thermal switch 5 = 24V DC, thermal switch |  |\n| Load & Speed | See page 2 |  |  |  |  |\n| Stroke (mm) | See page 2 |  |  |  |  |\n| Retracted Length (mm) | See page 5 |  |  |  |  |\n| Rear Attachment (mm)\u003Cbr>See page 6 | 1 = \\#45 Steel, slotless, hole 10.2\u003Cbr>2 = \\#45 Steel, slotless, hole 12.8\u003Cbr>3 = \\#45 Steel, U clevis, slot 8.2, depth 15.0, hole 10.2 4 = \\#45 Steel, U clevis, slot 8.2, depth 15.0, hole 12.8 5 = Stainless Steel, slotless, hole 10.2 |  |  | 6 = Stainless Steel, slotless, hole 12.8\u003Cbr>7 = Stainless Steel, U clevis, slot 8.2, depth 15.0, hole 10.2 8 = Stainless Steel, U clevis, slot 8.2, depth 15.0, hole 12.8 9 = \\#45 Steel, slotless, hole 16.2 |  |\n| Front Attachment (mm)\u003Cbr>See page 6-7 | 1 = \\#45 Steel, slotless, hole 10.2\u003Cbr>2 = \\#45 Steel, slotless, hole 12.8\u003Cbr>3 = \\#45 Steel, U clevis, slot 8.2, depth 15.0, hole 10.2 4 = \\#45 Steel, U clevis, slot 8.2, depth 15.0, hole 12.8 5 = Stainless Steel, slotless, hole 10.2 |  |  | 6 = Stainless Steel, slotless, hole 12.8\u003Cbr>7 = Stainless Steel, U clevis, slot 8.2, depth 15.0, hole 10.2 8 = Stainless Steel, U clevis, slot 8.2, depth 15.0, hole 12.8 9 = \\#45 Steel, slotless, hole 16.2\u003Cbr>K = Rod end bearing, hole 12.8 |  |\n| Direction of\u003Cbr>Rear Attachment (Counterclockwise)\u003Cbr>See page 7 | 1 = 0° 2 = 45° |  |  | 3 = 90° 4 = 135° |  |\n| Function of Limit Switches\u003Cbr>See page 8 | 1 = Two limit switches cut off the actuator at EOS ( with MCU embedded)\u003Cbr>3 = Two limit switches send signal at EOS ( signal type: normally closed) |  |  | D = Two limit switches send signal at EOS (exclusive option for TID1)\u003Cbr>6 = Two limit switches cut off the actuator and send signal at EOS (signal type: normally open, when choosing \\#6, output signal is restricted to \\#0_without) |  |\n| External Signal of Actuator | 0 = Without 1 = Reed switch*1, tinned leads |  |  | 2 = Reed switch*2, tinned\u003Cbr>leads |  |\n| Output Signal | 0 = Without\u003Cbr>1 = Mechanical Pot.\u003Cbr>N = NPN Hall sensor*2 |  |  | P = PNP Hall sensor*2\u003Cbr>T = Hall sensor*2 input to T-Smart PCBA (T-Smart dedicated option) |  |\n| IP Rating | 1 = Without\u003Cbr>6 = IP66M | 7 = IP67\u003Cbr>8 = IP68 |  | 9 = IP69K |  |\n| Cable Exit | 1 = Single cable\u003Cbr>T = Direct cable out, 1+1 type: Military connector (A1) |  |  | + Molex 6P connector (P2) |  |\n| A1 / P1 Connector (mm)\u003Cbr>See page 7 | 01 = Tinned leads, unsheathed wire 50, stripped wire 10 |  |  |  ","cbCaihgFx90YehZ2","https://ap.wps.com/l/cbCaihgFx90YehZ2","pdf",1142604,"English","# Load and Speed Specifications\n## Motor speed, duty cycle, current\n## Load grouping and max stroke\n# Mechanical Dimensions\n## Drawing standard dimensions\n## Retracted length\n# Electrical and Signal Options\n## Voltage, output signal, limit switches\n## External signal and IP rating\n# Attachments and Wiring\n## Front/rear attachment codes\n## Cable exit and connector definitions\n# Alternatives and Communication Interfaces\n## SAE J1939 and Modbus options\n## Wire definition tables","[{\"question\":\"What information does the MA3-N data sheet include for actuator performance?\",\"answer\":\"It includes load (N), motor speed, duty cycle, typical current, and typical speed for different screw types and code groups, along with corresponding maximum stroke values.\"},{\"question\":\"How are limit switch behaviors at EOS defined?\",\"answer\":\"The sheet provides multiple function options describing whether limit switches cut off the actuator at EOS or send signals at EOS, including signal types such as normally open or normally closed depending on the selected option code.\"},{\"question\":\"Which output signal and external signal types are supported?\",\"answer\":\"Output signal options include no output, mechanical potentiometer, and hall sensors (NPN/PNP), and there are external signal options such as reed switch variants. It also lists an option for hall sensor input to a T-Smart PCBA.\"}]","MA3-N - Data Sheet - Load, Speed, and Output Signal Specifications | PDF",23]