[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-672758-105":3,"detail-sidebar-cat-0-en-105":79,"doc-detail-672758-en":129},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":72,"head_meta":74,"extra_data":76,"updated_unix":78},105,"en","loxon-xp-waterproofing-system-a24-1400-series","Loxon XP Waterproofing System - A24-1400 Series","","Loxon XP is an exterior, high-build exterior coating designed to protect concrete, CMU, stucco, and shotcrete/gunite against wind-driven rain, while offering flexibility, durability, and strong weather resistance. It is highly alkali and efflorescence resistant, alkali- and mildew-tested, and supports anti-carbonation performance. The coating can be applied to substrates with pH 6 to 13, requires no primer, and uses specified dry film thicknesses and pinhole limits for waterproofing performance.",{"@graph":14,"@context":71},[15,34,54],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/loxon-xp-waterproofing-system-a24-1400-series/672758/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":48,"encodingFormat":47,"isAccessibleForFree":49,"interactionStatistic":50},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/loxon-xp-waterproofing-system-a24-1400-series/672758.png","ImageObject",300,407,{"name":42,"@type":43},"miaandmiso","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-02",true,{"@type":51,"interactionType":52,"userInteractionCount":22},"InteractionCounter",{"@type":53},"ViewAction",{"@type":55,"mainEntity":56},"FAQPage",[57,63,67],{"name":58,"@type":59,"acceptedAnswer":60},"What surfaces can Loxon XP be applied to?","Question",{"text":61,"@type":62},"Loxon XP can be applied on concrete, CMU, stucco, and shotcrete/gunite substrates.","Answer",{"name":64,"@type":59,"acceptedAnswer":65},"What pH range is Loxon XP suitable for?",{"text":66,"@type":62},"Loxon XP may be applied to surfaces with a pH of 6 to 13.",{"name":68,"@type":59,"acceptedAnswer":69},"Does Loxon XP require a primer?",{"text":70,"@type":62},"No primer is required, according to the provided system guidance.","https://schema.org",{"og:url":32,"og:type":73,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":75,"canonical":32},"index,follow",{"doc_id":77,"site_id":7},672758,1793606794,{"code":4,"msg":80,"data":81},"success",[82,86,90,94,99,103,108,113,118,121,125],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":83,"show_sort_weight":84,"slug":85},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":87,"show_sort_weight":88,"slug":89},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},"Exam",70,"exam",{"id":95,"doc_module":4,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},5,"Comic",60,"comic",{"id":100,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":101,"slug":102},6,50,"technology",{"id":104,"doc_module":4,"doc_module_name":25,"category_name":105,"show_sort_weight":106,"slug":107},7,"Healthcare",40,"healthcare",{"id":109,"doc_module":4,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},8,"Research & Report",30,"research-report",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},9,"Religion & Spirituality",20,"religion-spirituality",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":119,"show_sort_weight":116,"slug":120},"World Cup","world-cup",{"id":122,"doc_module":4,"doc_module_name":25,"category_name":123,"show_sort_weight":122,"slug":124},10,"Lifestyle","lifestyle",{"id":126,"doc_module":4,"doc_module_name":25,"category_name":127,"show_sort_weight":95,"slug":128},19,"General","general",{"code":4,"msg":80,"data":130},{"doc_id":77,"user_id":131,"nickname":42,"user_avatar":132,"doc_module":4,"category_id":100,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":138,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":12,"update_tm":78,"read_time":95},7971478544854,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","| As of 10/05/2015.Complies with:   |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| OTC  \u003Cbr>Yes   | LEED@09CI  \u003Cbr>NA   |  |  |  |\n| SCAQMD  \u003Cbr>Yes   | LEEDO 09NC  \u003Cbr>NIA   |  |  |  |\n| CARB  \u003Cbr>Yes   | NIA二  \u003Cbr>LEEDO 09CS   |  |  |  |\n| CARB SCM 2007 Yes   | LEEDOH  \u003Cbr>NA   |  |  |  |\n| MPI\\#  \u003Cbr>Yes   | Yes  \u003Cbr>NGBS   |  |  |  |\n| CHARACTERISTICS  \u003Cbr>Loxon XP is an exterior,high build  \u003Cbr>coating that provides excellent flexibility,  \u003Cbr>durability and weather resistance.This  \u003Cbr>product will protect against wind-driven  \u003Cbr>rain when used on concrete,CMU,  \u003Cbr>stucco and shotcrete/gunite.It is highly  \u003Cbr>alkali and efflorescence resistant.This  \u003Cbr>may be applied to a surface with a pH of  \u003Cbr>6 to 13.  \u003Cbr>·Apply directly to fresh concrete (at  \u003Cbr>least 7 days old)  \u003Cbr>·Shotcrete/gunite surfaces may be  \u003Cbr>painted after 3 days  \u003Cbr>·Can be applied over high pH(up to  \u003Cbr>13)substrates  \u003Cbr>·No primer required  \u003Cbr>·Improved roller appearance  \u003Cbr>·Can be applied down to 35°F  \u003Cbr>PHYSICAL PROPERTIES  \u003Cbr>Wind-Driven Rain Test.…………Passes  \u003Cbr>ASTM D6904-03  \u003Cbr>2cts Loxon XP@6.4-8.3 mils df/ct  \u003Cbr>Water Vapor Permeance    …9.6 perms  \u003Cbr>Based on ASTM D1653  \u003Cbr>1ct Loxon XP at 9.4 mils dft  \u003Cbr>14 day cure @77°F&50%RH  \u003Cbr>Elongation………………  ……275%  \u003Cbr>ASTM D2370  \u003Cbr>1 ct Loxon XP at 9.4mils dft  \u003Cbr>14 day cure @77°F&50%RH  \u003Cbr>Tensile Strength………………………285 psi  \u003Cbr>ASTM D2370  \u003Cbr>1 ct Loxon XP at 9.4 mils dft  \u003Cbr>14 day cure @77F&50%RH  \u003Cbr>Flexibility……                 Passes  \u003Cbr>ASTM D522  \u003Cbr>Alkali Resistance…        …Passes  \u003Cbr>Based on ASTM D1308  \u003Cbr>Mildew Resistance…           Passes  \u003Cbr>ASTM D3273/D3274  \u003Cbr>CO,Diffusion (anti-carbonation)  \u003Cbr>ASTM F2476…   …………344meters  \u003Cbr>Equivalent Air Thickness >50 meters to pass  \u003Cbr>……     …    …8.0 g/m²/24 hrs  \u003Cbr>Chloride lon Permeability  …243 coulombs  \u003Cbr>\"Very Low\"Permeability Class  \u003Cbr>Crack Bridging…………………Class A5  \u003Cbr>EN 1062-7 Method A…………up to 2.5mm@-10℃   |  |  | SPECIFICATIONS  \u003Cbr>Most colors  \u003Cbr>Color:  \u003Cbr>1 coat system,brush,roller,or spray  \u003Cbr>applied,coverage per coat:  \u003Cbr>6.4-8.3 mils dry  \u003Cbr>14-18 mils wet  \u003Cbr>90-115 sq ft/gal  \u003Cbr>Can be applied up to 40 mils wet.  \u003Cbr>Coverage will vary with the substrate anc  \u003Cbr>the texture.  \u003Cbr>Coverage on porous &rough stucco 80  \u003Cbr>square feet per gallon.  \u003Cbr>Drying Time,@50%RH:  \u003Cbr>temperature and humidity dependent  \u003Cbr>@35-45°F  \u003Cbr>@45F+  \u003Cbr>Touch:  \u003Cbr>6 hour  \u003Cbr>4 hours  \u003Cbr>24-48 hours  \u003Cbr>Recoat:  \u003Cbr>24 hours  \u003Cbr>Drving and recoat times are temperature,humidity  \u003Cbr>and film thickness dependent.  \u003Cbr>Flash Point:  \u003Cbr>N/A  \u003Cbr>0-10 units@85°  \u003Cbr>Finish:  \u003Cbr>Tinting with CCE only:  \u003Cbr>Base  \u003Cbr>oz/gal  \u003Cbr>Strength  \u003Cbr>Extra White  \u003Cbr>100%  \u003Cbr>0-5  \u003Cbr>Deep Base  \u003Cbr>4-12  \u003Cbr>100%  \u003Cbr>Uitradeep  \u003Cbr>4-12  \u003Cbr>100%  \u003Cbr>Light Yellow  \u003Cbr>100%  \u003Cbr>4-12  \u003Cbr>Vehicle Type:  \u003Cbr>Styrene Acrylic  \u003Cbr>A24W01451  \u003Cbr>VOC(less exempt solvents):  \u003Cbr>\u003C50 g/L;\u003C0.42 Ib/gal  \u003Cbr>As per 40 CFR 59.406 and SOR/2009-264,s.12  \u003Cbr>46±2%  \u003Cbr>Volume Solids:  \u003Cbr>Weight Solids:  \u003Cbr>61±2%  \u003Cbr>Weight per Gallon:  \u003Cbr>11.47 Ib  \u003Cbr>Mildew Resistant  \u003Cbr>This coating contains agents which in.  \u003Cbr>hibit the growth of mildew on the surface  \u003Cbr>of this coating film.   | SPECIFICATIONS  \u003Cbr>For proper waterproofing performance  \u003Cbr>and to resist alkalies,2 coats of the coat-  \u003Cbr>ing MUST be applied between 14.0-  \u003Cbr>18.0 mils wet per coat.  \u003Cbr>A total dry film thickness of 12-16 mils  \u003Cbr>of topcoat and a surface with 10 or less  \u003Cbr>pinholes per square foot is required for a  \u003Cbr>waterproofing system.  \u003Cbr>For extremely porous block a coat of  \u003Cbr>Loxon Block Surfacer may be required to  \u003Cbr>achieve a pinhole free surface.  \u003Cbr>For rehabilitating existing concrete water  \u003Cbr>tanks,additional products may be used.  \u003Cbr>Concrete.Stucco.Concrete Block  \u003Cbr>CMU,Split-face Block,and other Ce.  \u003Cbr>mentitious surfaces  \u003Cbr>1 ct.  Loxon Block Surfacer (if needed  \u003Cbr>or  \u003Cbr>1ct Lox","cbCaibUFb56PTwxy","https://ap.wps.com/l/cbCaibUFb56PTwxy","pdf",158592,"English","# Characteristics\n## Application Guidelines\n## Physical Properties and Test Standards\n## Specifications and Coverage\n## Surface Preparation and Cleanup\n## Cautions and First Aid","[{\"question\":\"What surfaces can Loxon XP be applied to?\",\"answer\":\"Loxon XP can be applied on concrete, CMU, stucco, and shotcrete/gunite substrates.\"},{\"question\":\"What pH range is Loxon XP suitable for?\",\"answer\":\"Loxon XP may be applied to surfaces with a pH of 6 to 13.\"},{\"question\":\"Does Loxon XP require a primer?\",\"answer\":\"No primer is required, according to the provided system guidance.\"}]","Loxon XP Waterproofing System - A24-1400 Series | PDF"]