[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-672756-105":59,"doc-detail-672756-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","loxon-xp-waterproofing-masonry-coating-flat-lx11-50-series-application-and-compliance-specifications","Loxon XP - Waterproofing Masonry Coating-Flat LX11-50 Series - Application and compliance specifications","","Loxon XP is an exterior high-build masonry waterproofing coating designed to protect concrete, CMU, stucco, and shotcrete/gunite against wind-driven rain with excellent flexibility, durability, and weather resistance. It is highly alkali and efflorescence resistant and can be applied on surfaces with pH 6–13, including high-pH substrates up to 13 without primer. Coverage and drying/recoat times depend on conditions, and a two-coat system within specified wet mils is required. The document also lists VOC, solids, flash point, mildew resistance, shelf life, compliance standards, application temperature guidance, spray/brush/roller equipment tips, and lead-dust safety for surface preparation.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/loxon-xp-waterproofing-masonry-coating-flat-lx11-50-series-application-and-compliance-specifications/672756/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/loxon-xp-waterproofing-masonry-coating-flat-lx11-50-series-application-and-compliance-specifications/672756.png","ImageObject",300,407,{"name":92,"@type":93},"cryingin4k","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-02",true,{"@type":101,"interactionType":102,"userInteractionCount":14},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What substrates can Loxon XP be applied to, and is primer required on high-pH surfaces?","Question",{"text":111,"@type":112},"Loxon XP can protect concrete, CMU, stucco, and shotcrete/gunite. It can be applied over high-pH substrates up to pH 13 without requiring a primer.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What are the required coating thicknesses and pinhole targets for waterproofing?",{"text":116,"@type":112},"Apply 2 coats with 14.5–18.5 wet mils per coat, achieving a total dry film thickness of 13–16.8 mils. The waterproofing system requires 10 or fewer pinholes per square foot.",{"name":118,"@type":109,"acceptedAnswer":119},"What precautions are recommended when preparing surfaces that may contain old lead paint?",{"text":120,"@type":112},"Scraping or sanding old paint may release lead dust. The document advises avoiding exposure, wearing a NIOSH-approved respirator, and cleaning carefully with a HEPA vacuum and wet mopping, with additional guidance provided via the National Lead Information Hotline.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},672756,1793606789,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":24},137458181193,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","115.10  \nLoxon® XP  \nWaterproofing Masonry Coating-Flat LX11–50 Series  \nCHARACTERISTICS  \nLoxon XP is an exterior, high build coating that provides excellent flexibility, durability, and weather resistance. This product will protect against wind-driven rain when used on concrete, CMU, stucco and shotcrete/gunite. It is highly alkali and efflorescence resistant. This may be applied to a surface with a pH of 6 to 13.  \nApply directly to fresh concrete (at least 7 days old) .  \nShotcrete-gunite surfaces may be painted after 3 days.  \nCan be applied over high pH (up to 13) substrates, no primer required.  \nCan be applied down to 35°F.  \nColor: Most Colors  \n1 coat system, brush, roller, or spray applied, coverage per coat:  \nWet mils: 14.5-18.5  \nDry mils: 6.5-8.4  \nCoverage: 85-110 sq. ft. per gallon  \nCan be applied up to 40 mils wet.  \nCoverage will vary with the substrate and the texture. Coverage on porous & rough stucco 80 square feet per gallon.  \nDrying Schedule @ 50% RH:  \n@35-45°F @45+°F  \nTo touch 6 hours 4 hours  \nTo recoat 24-48 hours 24 hours  \nDrying and recoat times are temperature, humidity, and film thickness dependent.  \nFinish: 0-10 units @ 85°  \nTinting with CCE only:  \nBase  \nExtra White Deep Base Ultradeep Light Yellow  \noz. per gallon  \n0-6  \n4-12  \n10-12 0-12  \nStrength  \nSherColor  \nSherColor  \nSherColor  \nSherColor  \nExtra White LX11W0051  \n(may vary by color)  \nV.O.C. (less exempt solvents) :  \nless than 50 grams per litre; 0.42 lbs. per gallon  \nAs per 40 CFR 59.406  \nVolume Solids: 45 ±2%  \nWeight Solids: 61 ±2%  \nWeight per Gallon: 11.46 lbs  \nFlash Point: N.A.  \nVehicle Type: Proprietary Acrylic  \nShelf Life: 36 months , unopened  \nMildew Resistant:  \nThis coating contains agents which inhibit the growth of mildew on the surface of this coating film.  \nCOMPLIANCE  \nAs of 07/10/2025 , Complies with:  \nOTC  \nOTC Phase II  \nS.C.A.Q.M. D. CARB  \nCARB SCM 2007  \nCARB SCM 2020  \nCanada  \nLEED® v4 & v4 .1 Emissions LEED® v4 & v4 .1 V.O.C. EPD-NSF® Certified  \nMIR-Manufacturer Inventory MPI®  \nSWRI® -Wall Coating  \nYes  \nYes  \nYes  \nYes  \nYes  \nYes  \nYes  \nN/A  \nYes  \nYes  \nN/A \\#10, 40 Yes  \nAPPLICATION  \nTemperature:  \nminimum 35°F  \nThe following is a guide. Changes in pressures and tip sizes may be needed for proper spray characteristics. Always purge spray equipment before use with listed reducer. Any reduction must be compatible with the existing environmental and application conditions.  \nReducer: Do Not Reduce  \nAirless Spray:  \nPressure 2300 p.s. i.  \nTip .021 inch  \nBrush: Use a nylon-polyester brush such as Purdy® Pro-Extra®  \nRoller Cover: 1/2-1 1/2 inch nap synthetic roller cover such as Purdy® Marathon®  \nThe substrate and its condition will determine the application procedure. Considerations to minimize pinholes:  \n• 2 coat application with overnight drying between coats  \n• Spray application with backrolling  \n• Power rolling  \nSpray and backroll on porous & rough stucco to achieve required film build and a pin-hole free surface.  \nWhen the air temperature is at 35°F, substrates may be colder; prior to painting, check to be sure the air, surface, and material temperature are above 35°F and at least 5°F above the dew point. Avoid using if rain or snow is expected within 2-3 hours.  \nDo not apply at air or surface temperatures below 35°F or when air or surface temperatures may drop below 35°F within 48 hours.  \nDo not reduce.  \nAPPLICATION TIPS  \nFor proper waterproofing performance and to resist alkalies, 2 coats of the coating MUST be applied between 14.5-18.5 mils wet per coat.  \nA total dry film thickness of 13 - 16.8 mils of topcoat and a surface with 10 or less pinholes per square foot is required for a waterproofing system.  \nFor extremely porous block a coat of Loxon Block Surfacer may be required to achieve a pinhole free surface.  \nFor rehabilitating existing concrete water tanks, additional products may be used.  \nRECOMMENDED SYSTEMS  \nConcrete, Stucco, Concrete Block, CMU, Splitfa","cbCainOWQUs1UIC5","https://ap.wps.com/l/cbCainOWQUs1UIC5","pdf",179386,"English","# Characteristics\n# Compliance\n# Application\n## Temperature and application tips\n# Recommended systems\n# Surface preparation & lead safety","[{\"question\":\"What substrates can Loxon XP be applied to, and is primer required on high-pH surfaces?\",\"answer\":\"Loxon XP can protect concrete, CMU, stucco, and shotcrete/gunite. It can be applied over high-pH substrates up to pH 13 without requiring a primer.\"},{\"question\":\"What are the required coating thicknesses and pinhole targets for waterproofing?\",\"answer\":\"Apply 2 coats with 14.5–18.5 wet mils per coat, achieving a total dry film thickness of 13–16.8 mils. The waterproofing system requires 10 or fewer pinholes per square foot.\"},{\"question\":\"What precautions are recommended when preparing surfaces that may contain old lead paint?\",\"answer\":\"Scraping or sanding old paint may release lead dust. The document advises avoiding exposure, wearing a NIOSH-approved respirator, and cleaning carefully with a HEPA vacuum and wet mopping, with additional guidance provided via the National Lead Information Hotline.\"}]","Loxon XP - Waterproofing Masonry Coating-Flat LX11-50 Series - Application and compliance specifications | PDF"]