[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-506088-105":59,"doc-detail-506088-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","low-cycle-fatigue-behavior-of-iter-like-divertor-target-under-demo-relevant-operation-conditions","Low cycle fatigue behavior of ITER-like divertor target under DEMO-relevant operation conditions","","Low cycle fatigue behavior of the copper alloy cooling tube and the copper interlayer of an ITER-like divertor target is investigated for nine combinations of DEMO-relevant loading and cooling conditions. LCF lifetime is evaluated as a function of loading and cooling parameters using cyclic plasticity simulation together with ITER-relevant material LCF data. Predictions show no critical fatigue failure for the copper alloy tube under high heat flux up to 18 MW/m2 if initial strength is maintained. The copper interlayer near the bond-interface free-surface edge shows strong plastic dissipation, with lifetime below 3000 cycles for HHF above 15 MW/m2, while the bulk remains at least 7000 cycles. Lifetime decreases with increasing HHF load and decreasing coolant temperature.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/low-cycle-fatigue-behavior-of-iter-like-divertor-target-under-demo-relevant-operation-conditions/506088/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/low-cycle-fatigue-behavior-of-iter-like-divertor-target-under-demo-relevant-operation-conditions/506088.png","ImageObject",300,407,{"name":92,"@type":93},"Angel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-05","2026-10-04",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",13,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What parts of the ITER-like divertor target are analyzed for LCF behavior?","Question",{"text":113,"@type":114},"The study analyzes the copper alloy cooling tube and the copper interlayer of an ITER-like divertor target under DEMO-relevant operating conditions.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How is LCF lifetime evaluated in this work?",{"text":118,"@type":114},"LCF lifetime is presented as a function of loading and cooling conditions using cyclic plasticity simulation and LCF data for materials relevant to ITER.",{"name":120,"@type":111,"acceptedAnswer":121},"What trends are predicted for LCF lifetime with respect to heat flux and coolant temperature?",{"text":122,"@type":114},"LCF lifetime decreases when HHF load increases or when coolant temperature decreases, with the copper interlayer near the bond-interface edge being especially sensitive.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},506088,1791295915,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":36,"preview_page_count":19,"preview_urls":146},687207412472,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Low cycle fatigue behavior of ITER-like divertor target under DEMO-relevant operation conditions  \nMuyuan Lia , Ewald Wernera , Jeong-Ha Youb,∗  \na Lehrstuhl für Werkstoﬀkunde und Werkstoﬀmechanik, Technische Universität München, Boltzmannstr.15, 85748 Garching,  \nGermany  \nb Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching, Germany  \nAbstract  \nIn this work the low cycle fatigue (LCF) behavior of the copper alloy cooling tube and the copper interlayer of an ITER-like divertor target is reported for nine diﬀerent combinations of loading and cooling conditions relevant to DEMO divertor operation. The LCF lifetime is presented as a function of loading and cooling conditions considered here by means of cyclic plasticity simulation and using LCF data of materials relevant for ITER. The numerical predictions indicate, that fatigue failure will not be an issue for the copper alloy tube under a high heat ﬂux (HHF) load of up to 18 MW/m2 as long as it preserves its initial strength. In contrast, the copper interlayer exhibits signiﬁcant plastic dissipation at the free surface edge of the bond interface adjacent to the cooling tube, where the LCF lifetime is predicted to be below 3000 load cycles for HHF loads higher than 15 MW/m2 . Most of the bulk region of the copper interlayer away from the free surface edge does not experience severe plastic fatigue and hence does not pose any critical concern as the LCF lifetime is predicted to be at least 7000 load cycles. LCF lifetime decreases as HHF load is increased or coolant temperature is decreased.  \nKeywords: divertor, low cycle fatigue, ﬁnite element method  \n1. Introduction  \nThe inner and outer vertical target plate has the highest thermal loading of the divertor cassette and thus has to be actively cooled by a coolant in long pulse fusion operation. According to the latest ’Work plan of the European roadmap for fusion power’, a water-cooled divertor is foreseen as the primary design option for the 1st generation DEMO reactor [1, 2] . The decision in favor of water-cooling is mainly owing to the superior heat removal capability of the water-cooled target concept compared with a helium-cooled counterpart. This feature is an essential advantage in eﬀorts to enhance the power exhaust capacity of a power plant. Furthermore, the engineering of a water-cooled target can proﬁt from the mature technology readiness level that may be attributed to the ample R&D experience accumulated in the ITER project. For this reason, an ITER-like divertor target design is currently considered as one of the initial reference models for the DEMO divertor [3] . The ITER divertor target is characterized as a serial array of rectangular tungsten monoblocks connected by a copper alloy cooling tube running through the central region of themonoblocks. Here, the cooling tube is the only structural member whereas the plasma-facing tungsten  \n∗ Corresponding author. Tel.: +49 (0)89 3299 1373; fax:+49 (0)89 3299 1212 . Email address: [you@ipp.mpg.de](you@ipp.mpg.de) (Jeong-Ha You)  \n/ 00 (2014) 1–16 2  \narmor is regarded as functional part. This means that the target design has to fulﬁll the requirements of a structural design code for the cooling tube.  \nRecently, an extensive design-to-code study has been conducted by a research group at ENEA for an ITER-like target design assuming DEMO-relevant loading and cooling conditions (heat ﬂux: 10 MW/m2 , coolant temperature: 200◦ C, coolant pressure: 5 MPa) [3] . This study showed that the ITER-like target with an optimized geometry could pass the elastic structural design criteria of the ITER SDC-IC code provided that the applied kinematic constraints are statically determinate [3, 4] . It turned out that the cooling tube of the ITER-like target could just pass the 3Sm criterion of the C type (cyclic) load category indicating that progressive plastic deformation (ratchetting) might be the most critical failure mode. On the other hand, the low cycle fa","cbCaicDsEQ3P6Mrn","https://ap.wps.com/l/cbCaicDsEQ3P6Mrn","pdf",569766,16,"English","# Abstract\n# Introduction\n# FE model\n## Geometry, FE mesh and materials","[{\"question\":\"What parts of the ITER-like divertor target are analyzed for LCF behavior?\",\"answer\":\"The study analyzes the copper alloy cooling tube and the copper interlayer of an ITER-like divertor target under DEMO-relevant operating conditions.\"},{\"question\":\"How is LCF lifetime evaluated in this work?\",\"answer\":\"LCF lifetime is presented as a function of loading and cooling conditions using cyclic plasticity simulation and LCF data for materials relevant to ITER.\"},{\"question\":\"What trends are predicted for LCF lifetime with respect to heat flux and coolant temperature?\",\"answer\":\"LCF lifetime decreases when HHF load increases or when coolant temperature decreases, with the copper interlayer near the bond-interface edge being especially sensitive.\"}]","Low cycle fatigue behavior of ITER-like divertor target under DEMO-relevant operation conditions | PDF",1791157380,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/9a75350ad6345d8d686c26fb1b2023be.webp",983,1272,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/7b86e5e32cd2ff843d0fd499e82a1f3a.webp",982,1270,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/1649c8a1d31e9fdef591e184edd3aabc.webp",981,1269,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/91788637b620bc6cccfae29c4383c8dd.webp",980,1268]