[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662605-105":59,"doc-detail-662605-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","lincoln-university-pawley-theater-renovation-schematic-design-pricing-set-issue-date-3-february-2023","LINCOLN UNIVERSITY PAWLEY THEATER RENOVATION - Schematic Design Pricing Set - Issue Date 3 February 2023","","Lincoln University Pawley Theater renovation schematic design pricing set issued 3 February 2023. The document lists cover sheet details and sheet index references, identifies involved architectural, engineering, theater planning, and MEP/acoustics/AV consultants, and provides project and contact information. It also includes standards, regulations, and administrative construction requirements covering permits, inspections, coordination with utilities, compliance with codes and referenced tests, handling hazardous materials, safety responsibilities, and procedures for maintaining protected systems and removing/disposal of construction debris.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/lincoln-university-pawley-theater-renovation-schematic-design-pricing-set-issue-date-3-february-2023/662605/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/lincoln-university-pawley-theater-renovation-schematic-design-pricing-set-issue-date-3-february-2023/662605.png","ImageObject",300,407,{"name":92,"@type":93},"I feel Different","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the issue date of the schematic design pricing set?","Question",{"text":112,"@type":113},"The set is issued on 3 February 2023.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the contractor’s core responsibilities under the standards and regulations?",{"text":117,"@type":113},"The contractor must comply with applicable building codes and obtain required permits and inspections, coordinate with utility providers, and follow referenced fire-rated tests and standards.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the document require the contractor to handle protected existing systems and debris removal?",{"text":121,"@type":113},"The contractor must maintain and protect systems and finishes to remain, repair or replace any damaged conditions to acceptable quality, and properly remove and dispose of demolition and construction debris with owner approval for removal details.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662605,1793220703,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":41},962093541761,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","© 2023 patterhn ives, llc ALL REPRODUCTION & INTELLECTUAL PROPERTY RIGHTS RESERVED-ORIGINAL DRAWING IS 24\" H x 42\" W  \nLINCOLN UNIVERSITY PAWLEY THEATER RENOVATION  \nS C H E M A T I C D E S I G N P R I C I N G S E T  \nI S S U E D A T E : 3 F E B R U A R Y 2 0 2 3  \n04 ~~ ~~EG~~0~~X~~00~~ISTING~~ ~~PHOTO:~~ ~~PAWLEY~~ ~~THEATER~~ ~~  \n| | MLK HALL |\n| --- | --- |\n| |  |\n\nNORTH  \n03 ~~ ~~CAG~~000~~MPUS~~ ~~CONTEXT~~ ~~MAP~~ ~~  \nSHEET   SHEET TITLE  \nPROJECT NUMBER: XXXX  \nPAWLEY THEATER R E N O V A T I O N  \nM A R T I N L U T H E R K I N G H A L L  \nl i n c o l n u n i v e r s i t y 8 2 0 c h e s t n u t s t r e e tj e f f e r s o n c i t y m i s s o u r i 6 5 1 0 1 p h o n e : 5 7 3 . 6 8 1 . 5 0 8 4  \nARCHITECT:  \npatterhn ives llc  \n1 3 0 s o u t h b e m i s t o n a v e n u es u i t e 8 0 0  \ns t l o u i s m i s s o u r i 6 3 1 0 5 3 1 4 8 3 3 0 3 0 1 [w w w . p a t t e r h n - i v e s . c o m](w w w . p a t t e r h n - i v e s . c o m)[ ](w w w . p a t t e r h n - i v e s . c o m)[MO State Certificate of Authority \\#A2014032538](MO State Certificate of Authority #A2014032538)  \nMEPFT, ACOUSTICS & AV:  \nMcCLURE ENGINEERING  \n1 0 0 0 c l a r k a v e n u es t l o u i s m i s s o u r i 6 3 1 0 2 3 1 4 6 4 5 6 2 3 2 [w w w . m c c l u r e e n g . c o m](w w w . m c c l u r e e n g . c o m)  \nTHEATER PLANNING:  \nS C H U L E R S H O O K  \n2 1 9 m a i n s t r e e t s es u i t e 2 0 0  \nm i n n e a p o l i s m i n n e s o t a 5 5 4 1 4 6 1 2 3 3 9 5 9 5 8 [w w w . s c h u l e r s h o o k . c o m](w w w . s c h u l e r s h o o k . c o m)  \n\n| LU PROJECT NUMBER: | API PROJECT NUMBER: |\n| --- | --- |\n| XXXX | 2207 |\n\nWHEN DRAWING IS REPRODUCED AT ORIGINAL SCALE , THIS BAR = 1 INCH  \n1\"  \nPROFESSIONAL SEALS:  \nNOT FOR CONSTRUCTION  \nNORTH  \nEAST DUNKLIN STREET  \nCHESTNUT STREET  \n\n| G000 | COVER SHEET |\n| --- | --- |\n| G001 | GENERAL NOTES, ABBREVIATIONS & SYMBOLOGY |\n| G002 | EXISTING PHOTOS--FOR REFERENCE ONLY\u003Cbr>EXISTING CONDITIONS DRAWINGS |\n\nGENERAL  \nERIC R. HOFFMAN-ARCHITECT MO\\# A-2010003447  \nREVISION HISTORY:  \nno. description date  \nEX201  \nEX301  \nEX401  \nEXISTING CONDITIONS FLOOR PLANS  \nEXISTING CONDITIONS REFLECTED CEILING PLANS EXISTING CONDITIONS THEATER & LOBBY SECTION  \nSELECTIVE REMOVAL  \n\n|  |\n| --- |\n|  |\n|  |\n|  |\n\n\n| D201 | SELECTIVE REMOVAL PLANS ~~ ~~\u003Cbr>\u003Cbr>ARCHITECTURE |\n| --- | --- |\n\nA201  \nA301  \nA401  \nA600  \nFLOOR PLANS REFLECTED CEILING PLANS THEATER & LOBBY SECTION  \nINTERIOR ELEVATIONS AND SCHEDULES  \nSHEET TITLE:  \nCOVER SHEET  \nSHEET NUMBER:  \nG000  \nSD PRICING  \n02 ~~ ~~AEG0~~00~~RIAL~~ ~~LOCATION~~ ~~MAP~~ ~~  \n01 ~~ ~~DRG~~000~~AWING~~ ~~INDEX~~ ~~  \nDRAWN BY: ISSUE DATE:  \nAPI 3 FEBRUARY 2023  \nLINCOLN UNIVERSITY MISSOURI -PAWLEY THEATER RENOVATION LU PROJECT NUMBER: XXXX  \n© 2023 patterhn ives, llc ALL REPRODUCTION & INTELLECTUAL PROPERTY RIGHTS RESERVED-ORIGINAL DRAWING IS 24\" H x 42\" W  \nSTANDARDS AND REGULATIONS  \n1. CONTRACTOR SHALL PERFORM ALL WORK IN CONFORMANCE WITH APPLICABLE BUILDING CODES, REGULATIONS, ORDINANCES, UTILITY PROVIDER REQUIREMENTS, AND SIMILAR STANDARDS.  \n2. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASES REQUIRED FOR CONSTRUCTION AND OCCUPANCY. CONTRACTOR SHALL FURNISH COPIES OF ALL SUCH ITEMS TO OWNER AND ARCHITECT WITHIN 10 DAYS OF RECEIPT. IF PERMITS ARE ISSUED SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE WORK OR IF PERMITS ARE DELAYED FOR ANY REASON, CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY.  \n3. CONTRACTOR SHALL OBTAIN ALL REQUIRED INSPECTIONS OF THE WORK. CONTRACTORSHALL REGULARLY UPDATE OWNER AND ARCHITECT REGARDING THE STATUS OF INSPECTIONS.  \n4. IF APPLICABLE, CONTRACTOR SHALL FILE NOTICE OF INTENT WITH THE ENVIRONMENTAL PROTECTION AGENCY (EPA) .  \n5. CONTRACTOR SHALL COORDINATE WORK WITH ALL APPLICABLE UTILITY PROVIDERS.  \n6. CONTRACTOR SHALL BE FAMILIAR WITH ALL DOCUMENTS AND WORK AND SHALL BE IN COMPLIANCE WITH REFERENCED FIRE-RATED ASSEMBLY TESTS & STANDARDS.  \n7. IF UNANTICIPATED HAZARDOUS MATERIALS ARE ENCOUNTERED, CONTRACTOR S","cbCaiqC52h8nVjcr","https://ap.wps.com/l/cbCaiqC52h8nVjcr","pdf",10766274,12,"English","# Standards and Regulations\n## Contractor compliance with building codes and permits\n## Contractor inspections and environmental notification\n## Coordination with utility providers and fire-rated standards\n## Hazardous materials procedure\n# Administration of the Work\n## Means, methods, and sequence responsibilities\n## Personnel and visitor safety\n## Document discrepancies reporting\n## Protection, repair, and replacement of existing systems\n## Debris removal, approvals, and restoration\n## Secure site procedures\n## Disabling and reactivating existing building systems","[{\"question\":\"What is the issue date of the schematic design pricing set?\",\"answer\":\"The set is issued on 3 February 2023.\"},{\"question\":\"What are the contractor’s core responsibilities under the standards and regulations?\",\"answer\":\"The contractor must comply with applicable building codes and obtain required permits and inspections, coordinate with utility providers, and follow referenced fire-rated tests and standards.\"},{\"question\":\"How does the document require the contractor to handle protected existing systems and debris removal?\",\"answer\":\"The contractor must maintain and protect systems and finishes to remain, repair or replace any damaged conditions to acceptable quality, and properly remove and dispose of demolition and construction debris with owner approval for removal details.\"}]","LINCOLN UNIVERSITY PAWLEY THEATER RENOVATION - Schematic Design Pricing Set - Issue Date 3 February 2023 | PDF"]