[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-653821-105":59,"doc-detail-653821-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","lh-224-installation-tool-instruction-manual","LH-224 - Installation Tool Instruction Manual","","Instruction manual for the Huck International Ltd. LH-224 hydraulic installation tool, providing safety guidelines, glossary terms (warnings, cautions, notes), and operational instructions. Covers intended use, specifications, electrical and air/hydraulic supply considerations, nozzle assembly checks, and inspection for damage or leakage. Describes safe operating practices such as eye protection, keeping hands clear, correct collar orientation for two-piece fasteners, noise and hearing protection guidance, and handling of pintail ejection. Includes preparation, servicing, preventative maintenance, disassembly/assembly, and filling and bleeding procedures.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/lh-224-installation-tool-instruction-manual/653821/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/lh-224-installation-tool-instruction-manual/653821.png","ImageObject",300,407,{"name":92,"@type":93},"miaandmiso","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-25",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is allowed to operate the LH-224 installation tool?","Question",{"text":112,"@type":113},"Only persons trained and approved by Huck International Ltd. may use Huck installation equipment. Servicing and operating the tool require reading the manuals and supplied warning labels.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What safety precautions are required during operation?",{"text":117,"@type":113},"Wear approved eye protection, keep hands and fingers clear of moving parts and apertures, and do not look directly at the front or rear of the tool or the head/blind side of fasteners during the cycle. Use hearing protection if noise exceeds the Noise at Work first action level.",{"name":119,"@type":110,"acceptedAnswer":120},"What should be checked before connecting the tool to power?",{"text":121,"@type":113},"Ensure the Powerig or approved hand pump pressures are correctly adjusted for the tool, verify the nose assembly is correct for the fastener, and visually inspect hoses, cables, and connectors for damage or leakage. Do not connect equipment showing signs of damage or leakage.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},653821,1793030075,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},7971478544854,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","| Instruction Manual LH-224 & LH-224BPneudraulic Installation Tool |  |\n| --- | --- |\n| |  |\n| | Huck International Ltd. LH-224 ENG Revision: 17.02.00 |\n\nContents  \nSafety Guidelines 1 & 2  \nSafety Glossary 3  \nDescription 4  \nIntended Use 4  \nSpecifications 4  \nDisposal 4  \nDimensions 5  \nPrinciple of Operation 6  \nPreparation for Use 6  \nInstructions for Use 8  \nServicing and Preventative Maintenance 9  \nDisassembly 10  \nMain Components 14  \nAssembly 15  \nFilling and Bleeding Procedure 17  \nExploded View 19  \nParts List 20  \nPintail Collection Bottle 21  \nHuck Fastening Systems  \nSafety Guidelines when using Huck Installation Equipment to install Huck Fasteners.  \nBefore using equipment:  \n1. Only Huck Installation Equipment should be used to install Huck fasteners.  \n2. Only persons that have received training approved by Huck International Ltd should use Huck Installation Equipment.  \n3. The Manuals and/or Data sheets and warning stickers/labels supplied with the Installation equipment should be studied before connecting the equipment to any primary power supply, in particular the following sections:  \nWarnings and Cautions. Specifications  \nElectrical and/or Air supply. Principals of Operation.  \nPreparation for use.  \nRegular use.  \nRegular maintenance.  \n4. W ith hydraulic tooling, ensure that it is suitable for use with the Huck Powerig or Huck approved hand pump being used.  \n5. Check that the Powerig or approved hand pump \"Pull\" and \"Return\" pressures have been adjusted to suit the tool being used. Reference must be made to the instruction manual supplied with the equipment.  \n6. Check that the Nose Assembly is of the correct type suitable for installing the fastener being used.  \n7. Visually check all pneumatic and/or hydraulic hoses, electrical cables, Powerigs, hand pumps and hand tools, for any visible signs of damage and leakage. ALL HYDRAULIC HOSES SHOULD BE RENEWED EVERY FIVE YEARS .  \n8. Do not connect any equipment to primary power supplies or attempt to use any equipment, that shows signs of damage or leakage.  \n9. Ensure that all air and/or hydraulic hose and/or electrical plugs/connectors are correctly connected before switching on supply to equipment.  \nWhen operating the equipment:  \n10. When using fasteners in some types of structure, the fracturing of the pintail during installation may generate noise levels above the first action level of the Noise at Work  \nRegulations and therefore hearing protection must be worn.  \n11. It is recommended that eye protection,(eg. safety glasses), should be worn by the operator .  \n12. Never look directly at the front or rear of the installation tool.  \n13. Never hold the Installation Tool around the Nose Assembly.  \n14. Keep hands/fingers clear of any moving parts and also apertures in Nose Assemblies.  \n15. W arning  \nFasteners should only ever be installed in the actual workpiece to prevent possible high velocity ejection from the Nose Assembly due to tensile forces induced during pintail fracture.  \n16. When using two piece fasteners, (ie. Pin and Collar type), the  \nconical/chamfered end of the collar MUST always be towards the Nose assembly, NOT against the work piece.  \n17. Keep fingers clear from the underside of the head, collars and blind side of fasteners and from within the joint being fastened, during the installation cycle.  \n18. Do not look directly at the head or blind side of fasteners during the installation cycle.  \n19. During the installation cycle, the tool will pull and straighten itself to the axis of the fastener, beware of hands being trapped against any nearby structure.  \nKEEP HANDS CLEAR  \n20. In the event of any difficulty whilst installing a fastener, releasing the tool trigger at any time during the installation cycle will immediately put the tool into reverse.  \n21. Beware of fastener pintails which are ejected, (sometimes forcibly), from the tool at the completion, or at pintail fracture, during the installation cycle. Tools designed ","cbCaihBjVvXT4PzZ","https://ap.wps.com/l/cbCaihBjVvXT4PzZ","pdf",1963069,26,"English","# Safety Guidelines\n## Safety Glossary\n# Description\n## Intended Use\n## Specifications\n## Disposal\n# Principle of Operation\n# Preparation for Use\n# Instructions for Use\n# Servicing and Preventative Maintenance\n# Disassembly\n# Main Components\n# Assembly\n# Filling and Bleeding Procedure\n# Exploded View\n# Parts List\n# Pintail Collection Bottle","[{\"question\":\"Who is allowed to operate the LH-224 installation tool?\",\"answer\":\"Only persons trained and approved by Huck International Ltd. may use Huck installation equipment. Servicing and operating the tool require reading the manuals and supplied warning labels.\"},{\"question\":\"What safety precautions are required during operation?\",\"answer\":\"Wear approved eye protection, keep hands and fingers clear of moving parts and apertures, and do not look directly at the front or rear of the tool or the head/blind side of fasteners during the cycle. Use hearing protection if noise exceeds the Noise at Work first action level.\"},{\"question\":\"What should be checked before connecting the tool to power?\",\"answer\":\"Ensure the Powerig or approved hand pump pressures are correctly adjusted for the tool, verify the nose assembly is correct for the fastener, and visually inspect hoses, cables, and connectors for damage or leakage. Do not connect equipment showing signs of damage or leakage.\"}]","LH-224 - Installation Tool Instruction Manual | PDF",1792900304,66]