[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-648395-105":59,"doc-detail-648395-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","lf-ii-machine-room-elevator-planning-guide-202405","LF-II - Machine Room Elevator Planning Guide - 2024.05","","LF-II Machine Room Elevator Planning Guide 2024.05 provides technical reference information for elevator configuration, including overall planning principles, limits of catalog accuracy, and guidance that specific parameters are subject to formal agreements. The guide includes contents covering elevator specifications, car design, decoration device and elements, elevator functions, hoistway and machine room considerations, entrance design, and electrical information and data. It also lists rated load/speed ranges, one-time loading limits, floor height requirements, and key safety and operating functions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/lf-ii-machine-room-elevator-planning-guide-202405/648395/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/lf-ii-machine-room-elevator-planning-guide-202405/648395.png","ImageObject",300,407,{"name":92,"@type":93},"Tirek","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-25","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of the LF-II catalogue and what does it guarantee?","Question",{"text":112,"@type":113},"It provides general planning information about LF-II elevator technical features and configuration. The guide also states that the information and diagrams reflect the model configuration at press time and are subject to change without notice, and it is not a contract document.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What specification data are provided for LF-II planning?",{"text":117,"@type":113},"The guide includes rated load and rated speed, maximum one-time loading, maximum number of stops, maximum travel, and minimum floor height. It also references requirements and notes related to one-time loading and applicable standards.",{"name":119,"@type":110,"acceptedAnswer":120},"Which standard functions are listed in the elevator function section?",{"text":121,"@type":113},"The guide lists standard functions under the control system categories, including selective collective control, maintenance and slow-speed operations, overspeed protections, automatic fault detection/recording, brake-safety checks, automatic correction functions, and protections such as UCMP.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},648395,1792906621,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},5909896572756,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","LF-II  \nThe information in this catalogue is subject to change without notice. The information and diagram in this catalogue reflect the technical features and configuration of the elevator model at press time (refer to the version number) . In line with the principle of continuous development of products, our company reserves the right to change the selection of product technical parameters and colour at any time. The existing image technology cannot accurately reproduce the elevator component structure and decoration colour. Therefore, this catalogue only provides general information, not as a contract document. The specific configuration parameters are subject to the formal agreement.  \nIf you need detailed information, please contact us.  \nCopyright: Hitachi Elevator (China) Co. , Ltd.  \nLF-II Planning Guide 2024.05  \nMachine Room Elevator Planning Guide  \nContents Elevator Specification  \n02 Elevator Specification  \n03 Car Design  \n07 Decoration Device  \n08 Decoration Elements  \n09 Elevator Function  \n11 Hoistway and Machine Room  \n25 Entrance Design  \n29 Electrical Information  \n30 Electrical Data  \n31 Civil Works Matters  \n\n| Rated Load\u003Cbr>(kg) | Rated Speed\u003Cbr>(m/min) | Maximum One\u003Cbr>Time Loading [\\#1]\u003Cbr>(kg) | Maximum\u003Cbr>Number of Stops | Maximum Travel\u003Cbr>(m) | Minimum\u003Cbr>Floor Height\u003Cbr>(mm) |\n| --- | --- | --- | --- | --- | --- |\n| 1600 | 30 | 960 | 8 | 40 | 2800 |\n|  | 60 |  | 16 | 70 |  |\n| 2000 | 30 | 1200 | 8 | 40 |  |\n|  | 60 |  | 16 | 70 |  |\n| 3000 | 30 | 1800 | 8 | 40 |  |\n|  | 60 |  | 16 | 70 |  |\n| 4000 | 30 | 2400 | 8 | 30 | 2800 |\n|  | 45 |  | 16 | 40 |  |\n| 5000 | 30 | 3000 | 8 | 30 |  |\n|  | 45 |  | 16 | 40 |  |\n| 4000 | 30 | 4000 | 16 | 30 | 3200 |\n|  | 45 |  |  | 60 |  |\n| 5000 | 30 | 5000 | 16 | 30 |  |\n|  | 45 |  |  | 60 |  |\n\nNotes:  \n[\\#1] Maximum one time loading refers to the maximum weight (Includes loading equipment, goods and handler) per loading.[\\#2] Rated load ≥ 4000kg: When using forklift for loading/unloading, the following requirements must be met.  \n(a) Maximum one time loading must be within the specification range.  \n(b) Total weight of the goods must be within the rated load.  \n(c) During loading, if the overload alarm sound, loading shall stop and forklift to exit the car immediately.[\\#3] The above information are based on GB7588-2003 standards.  \nCar Design Car Design  \n| Car Ceiling | Painted Steel_CP30 (Light Cyan) LED Lighting |\n| --- | --- |\n| Car Ceiling Height | 2200mm |\n| Entrance Height | 2100mm |\n| Car Door | Painted Steel_CP30 (Light Cyan) |\n| Car Walls | Painted Steel_CP30 (Light Cyan) |\n| Car Floor | Checkered Steel Plate |\n\n\n| Car Ceiling | Painted Steel_CP30 (Light Cyan) LED Lighting |\n| --- | --- |\n| Car Ceiling Height | 2200mm |\n| Entrance Height | 2100mm |\n| Car Door | Painted Steel_CP30 (Light Cyan) |\n| Car Walls | Painted Steel_CP30 (Light Cyan) |\n| Car Floor | Checkered Steel Plate |\n\n| Car Ceiling | Painted Steel_CP30 (Light Cyan) LED Lighting |\n| --- | --- |\n| Car Ceiling Height | 2400mm |\n| Entrance Height | 2400mm |\n| Car Door | Painted Steel_CP30 (Light Cyan) |\n| Car Walls | Painted Steel_CP30 (Light Cyan) |\n| Car Floor | Checkered Steel Plate |\n\nCar Design Car Design  \n| Car Ceiling | Stainless Steel Hairline\u003Cbr>LED Lighting |\n| --- | --- |\n| Car Ceiling Height | 2200mm |\n| Entrance Height | 2100mm |\n| Car Door | Stainless Steel Hairline |\n| Car Walls | Stainless Steel Hairline |\n| Anti-Collision Protection | Stainless Steel Hairline (3 Sides) |\n| Car Floor | Checkered Steel Plate |\n\n\n| Car Ceiling | Stainless Steel Hairline\u003Cbr>LED Lighting |\n| --- | --- |\n| Car Ceiling Height | 2200mm |\n| Entrance Height | 2100mm |\n| Car Door | Stainless Steel Hairline |\n| Car Walls | Stainless Steel Hairline |\n| Anti-Collision Protection | Stainless Steel Hairline (3 Sides) |\n| Car Floor | Checkered Steel Plate |\n\n| Car Ceiling | Stainless Steel Hairline\u003Cbr>LED Lighting |\n| --- | --- |\n| Car Ceiling Height | 2400mm |\n| Entrance Height | 2400mm |\n| Car Door | Stainl","cbCaitcs3JNqDpXH","https://ap.wps.com/l/cbCaitcs3JNqDpXH","pdf",4409513,18,"English","# Elevator Specification\n## Car Design\n## Decoration Device\n## Decoration Elements\n## Elevator Function\n## Hoistway and Machine Room\n## Entrance Design\n## Electrical Information\n## Electrical Data\n## Civil Works Matters","[{\"question\":\"What is the purpose of the LF-II catalogue and what does it guarantee?\",\"answer\":\"It provides general planning information about LF-II elevator technical features and configuration. The guide also states that the information and diagrams reflect the model configuration at press time and are subject to change without notice, and it is not a contract document.\"},{\"question\":\"What specification data are provided for LF-II planning?\",\"answer\":\"The guide includes rated load and rated speed, maximum one-time loading, maximum number of stops, maximum travel, and minimum floor height. It also references requirements and notes related to one-time loading and applicable standards.\"},{\"question\":\"Which standard functions are listed in the elevator function section?\",\"answer\":\"The guide lists standard functions under the control system categories, including selective collective control, maintenance and slow-speed operations, overspeed protections, automatic fault detection/recording, brake-safety checks, automatic correction functions, and protections such as UCMP.\"}]","LF-II - Machine Room Elevator Planning Guide - 2024.05 | PDF",1792793337,45]