[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-461728-105":59,"doc-detail-461728-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","level-limit-switch-liquiphant-ftl-360ftl-361","Level Limit Switch - Liquiphant FTL 360/FTL 361","","Liquiphant level limit switch for all liquid applications, monitoring minimum and maximum level limits in tanks and vessels. Suitable across wide temperature (-40 °C to +150 °C) and viscosity (up to 10.000 mm2/s) ranges, with density greater than 0.5 g/cm3. Plastic-coated or Hastelloy versions support particularly corrosive media. Replaces float switches and offers maintenance-free operation with millimetre-accurate switching and monitoring of fork corrosion via intelligent electronics.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/level-limit-switch-liquiphant-ftl-360ftl-361/461728/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/level-limit-switch-liquiphant-ftl-360ftl-361/461728.png","ImageObject",300,407,{"name":92,"@type":93},"SundayMiles","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-13","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What liquids can the Liquiphant level limit switch be used for?","Question",{"text":113,"@type":114},"It is designed for all types of liquids and can monitor upper and lower level limits in tanks and vessels.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Which environmental limits are specified for temperature, viscosity, and density?",{"text":118,"@type":114},"Temperatures from -40 °C to +150 °C are supported, viscosity up to 10.000 mm2/s (cSt) and density greater than 0.5 g/cm3.",{"name":120,"@type":111,"acceptedAnswer":121},"How does the Liquiphant detect the level limit?",{"text":122,"@type":114},"A tuning-fork sensor vibrates at its resonant frequency; when immersed, the frequency changes and is converted into a switching signal for the selected fail-safe mode.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},461728,1791363162,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":46,"preview_page_count":19,"preview_urls":145},1099529839202,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Technical Information TI 184F/00/en  \nLevel Limit Switch  \nliquiphantFTL 360 / FTL 361  \nLevel limit switch Liquiphant II with vibrating probe.  \nFor all types of liquid.  \nLiquiphant level limit switch:  \n• FTL 360, compact version  \n• FTL 361, with extension tube  \n• with various process connections  \n• with aluminium, plastic or stainless steel housing  \nApplication  \nThe Liquiphant is a level limit switch for all liquids.  \nIt can monitor the upper and lower level limits in tanks and vessels and is suitable for all liquids  \n• with temperatures lying between  \n–40 °C and +150 °C (–40 °F and +300 °F)  \n• with a viscosity up to 10.000 mm2/s (cSt)  \n• with a density greater than 0.5 g/cm3 For particularly corrosive liquids the plastic-coated versions or the Hastelloy–version are suitable. The Liquiphant is used wherever float switches were previously installed. It is also used in those applications where float switches are not suitable.(due to build-up, turbulence, flow, air bubbles) .  \nFeatures at a glance  \n• Maintenance free:  \nOperates completely reliably even with heavy build-up.  \n• Cost-effective: An economical standard Liquiphant can be used in all applications. It operates safely in all types of liquids and under all process conditions, independent of turbulence, electrical properties, solids or gas content, foam, or tank vibrations.  \n• Accurate switching: A constant switchpoint with millimetre accuracy without need for calibration.  \n• Operational safety: Thanks to its improved and patented system with intelligent drive electronics, the Liquiphant is unequalled in its tolerance to external vibrations The tines are monitored electronically for corrosion.  \n• Proven in practice: The reliability you need is the experience we offer with  \n1 000 000 measuring points already installed.  \nEndress+Hauser  \nNothing beats know-how  \nMeasurement Principle  \nMeasuring System  \nOperating principle of the Liquiphant  \nThe sensor in the form of tuning fork is made to vibrate at its resonant frequency. When the sensor is immersed in the liquid, the resonant frequency changes. The frequency change is detected and then converted into a switching signal. The built-in switch for minimum or maximum detection enables the Liquiphant to be used for each application in the required fail-safe mode.  \n• Liquiphant as compact version or with extension tube  \n• Process connection: Threaded boss, flange or hygienic coupling  \n• Electronic insert for alternating or direct current, with electronic switching or a relay contact  \n• Housing F6 Aluminium housing F8 Stainless steel housing F10 Polyester housing (PTB)  \nInstallation possibilities  \nA wide range of application-specific designs, process connections and high corrosion-resistant materials allows limit detection of all kinds of liquids in tanks and pipes.  \nA few examples:  \n Top mounting to monitor the maximum level. Optionally with a sliding sleeve to vary the switchpoint.  \n Side mounting to monitor the minimum level.  \n Mounted in a pipe as dry-run protection for the pump.  \nThe limit switch with greater operational safety, even for liquids which are adhesive, causing build-up, corrosive, agitated, sparkling or foaming.  \n\n| \u003Cbr>\u003Cbr>F6, F10 | |\n| --- | --- |\n\nHousing versions  \nProcess connections  \nApplication-specific process connections and designs ensure an ideal adaptability to the mounting requirements.  \n Threaded boss G 1 A or 1\" NPT  Flanges according to various  \nstandards: DIN, ANSI, JIS For particularly hygienic requirements, [e.g. food](e.g. food) processing:  \nMilk pipe coupling Triclamp􀃢 coupling Weld-in socket for flush  \nmounting  \nFork and extension tube are polished.  \nProcess connection materials:  \n– Stainless steel 316 Ti (1 .4571) or Hastelloy C (2 .4610),  \n– flange version additionally available with ECTFE (Halar􀃒 ) or PFA coating.  \nThreaded boss  \nG 1A or  \n1-111/2 NPT  \nPipe coupling  \nDIN 11851, DN 50  \nTriclamp coupling  \nISO 2852, 2\"  \nFlange version  \nDI","cbCaihAxc43flJVd","https://ap.wps.com/l/cbCaihAxc43flJVd","pdf",553219,"English","# Application\n## Liquiphant level limit switch for liquids\n# Features at a glance\n## Maintenance-free reliability\n## Accurate switching and safety\n# Measurement principle\n## Tuning fork resonance and switching signal\n# Variants and configurations\n## Compact and extension tube versions\n## Process connections and housing materials\n# Installation possibilities\n## Mounting positions and guidance\n# Nozzle and pipe mounting notes\n## Viscosity and distance requirements","[{\"question\":\"What liquids can the Liquiphant level limit switch be used for?\",\"answer\":\"It is designed for all types of liquids and can monitor upper and lower level limits in tanks and vessels.\"},{\"question\":\"Which environmental limits are specified for temperature, viscosity, and density?\",\"answer\":\"Temperatures from -40 °C to +150 °C are supported, viscosity up to 10.000 mm2/s (cSt) and density greater than 0.5 g/cm3.\"},{\"question\":\"How does the Liquiphant detect the level limit?\",\"answer\":\"A tuning-fork sensor vibrates at its resonant frequency; when immersed, the frequency changes and is converted into a switching signal for the selected fail-safe mode.\"}]","Level Limit Switch - Liquiphant FTL 360/FTL 361 | PDF",1790762255,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2f5a1318b9b45ce8a87a36270b7decca.webp",983,1390,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ac900e34297ad6b2420ba95dc0ffb513.webp",982,1389,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3e5d8076c1050736605e2b81313df298.webp",981,1387,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/cce274bdd85352ff8e6c87247a8f87b9.webp",980,1386]