[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-390533-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-390533-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","lead-coolant-test-facility-technical-and-functional-requirements-conceptual-design-cost-and-construction-schedule","Lead Coolant Test Facility Technical and Functional Requirements, Conceptual Design, Cost and Construction Schedule","","This report presents preliminary technical and functional requirements, thermal-hydraulic design basis, and cost estimate for a small-scale Lead Coolant Test Facility. The facility is intended to simulate lead-cooled fast reactor (LFR) coolant flow in an open-lattice geometry core using seven electrical heater rods and liquid lead or lead-bismuth eutectic. Requirements are organized into five broad requirement areas covering prototype flow loop development, submerged heat exchanger feasibility, open-lattice electrical core operation, chemistry control, and safe operation with provision for future testing. The design includes extensive instrumentation and a construction duration of about two years with an estimated cost of $3.7M.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/lead-coolant-test-facility-technical-and-functional-requirements-conceptual-design-cost-and-construction-schedule/390533/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/lead-coolant-test-facility-technical-and-functional-requirements-conceptual-design-cost-and-construction-schedule/390533.png","ImageObject",300,407,{"name":42,"@type":43},"Blitz","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-19","2026-09-25",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",15,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the purpose of the Lead Coolant Test Facility (LCTF)?","Question",{"text":63,"@type":64},"The LCTF is designed to simulate lead coolant fast reactor (LFR) coolant flow in an open lattice geometry core using seven electrical rods and liquid lead or lead-bismuth eutectic.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How are the requirements organized in the report?",{"text":68,"@type":64},"Five broad requirement areas are identified and then divided into twenty-one specific requirements spanning topics such as coolant temperature, design lifetime, engineering, QA, and environmental requirements.",{"name":70,"@type":61,"acceptedAnswer":71},"What are the reported thermal-hydraulic and instrumentation basis values?",{"text":72,"@type":64},"The thermal-hydraulic design is based on a maximum simulated core power of 7 electrical heater rods at 420 kW, an average linear heat generation rate of 300 W/cm, a core inlet temperature of 420°C, and approximately seventy-five data measurements including pressure, temperature, and flow rates.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},390533,1790763529,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":140,"language":141,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":12,"update_tm":145,"read_time":146,"preview_page_count":112,"preview_urls":147},24464137899374,"https://us-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","INL/EXT-06-11768  \nLead Coolant Test Facility Technical and Functional Requirements, Conceptual Design, Cost and Construction Schedule  \nSoli Khericha September 2006  \nThe INL is a U.S. Department of Energy National Laboratory operated by Battelle Energy Alliance  \nINL/EXT-06-11768  \nLead Coolant Test Facility Technical and Functional Requirements, Conceptual Design, Cost and Construction Schedule  \nSoli Khericha  \nSeptember 2006  \nIdaho National Laboratory  \nIdaho Falls, Idaho 83415  \nPrepared for the  \nU.S. Department of Energy  \nOffice of Nuclear Energy, Science and Technology  \nUnder DOE Idaho Operations Office  \nContract DE-AC07-05ID14517  \nLead Coolant Test Facility Technical and Functional Requirements, Pre-conceptual Design, and Cost  \nEstimate  \nINL/EXT-06-11768  \nSeptember 2006  \nReviewed by Date:  \nEdwin Harvego  \nApproved by Date:  \nABSTRACT  \nThis report presents preliminary technical and functional requirements (T&FR), thermal hydraulic design and cost estimate for a lead coolant test facility. The purpose of this small scale facility is to simulate lead coolant fast reactor (LFR) coolant flow in an open lattice geometry core using seven electrical rods and liquid lead or lead-bismuth eutectic. Based on review of current world lead or lead-bismuth test facilities and research need listed in the Generation IV Roadmap, five broad areas of requirements of basis are identified:  \nDevelop and Demonstrate Prototype Lead/Lead-Bismuth Liquid Metal Flow Loop  \nx Develop and Demonstrate Feasibility of Submerged Heat Exchanger  \nx Develop and Demonstrate Open-lattice Flow in Electrically Heated Core  \nx Develop and Demonstrate Chemistry Control  \nx Demonstrate Safe Operation and Provision for Future Testing  \nThese five broad areas are divided into twenty-one (21) specific requirements ranging from coolant temperature to design lifetime. An overview of project engineering requirements, design requirements, QA and environmental requirements are also presented. The purpose ofthis T&FRs is to focus the lead fast reactor community domestically on the requirements for the next unique state ofthe art test facility. The facility thermal hydraulic design is based on the maximum simulated core power using seven electrical heater rods of 420 kW; average linear heat generation rate of 300 W/cm. The core inlet temperature for liquid lead or Pb/Bi eutectic is 420oC. The design includes approximately seventy-five data measurements such as pressure, temperature, and flow rates. The preliminary estimated cost of construction of the facility is $3 .7M. It is also estimated that the facility will require two years to be constructed and ready for operation.  \niv  \nSUMMARY  \nThis document is divided into three main sections; technical and functional requirement (TF&R), conceptual design, and cost estimate. The Lead Coolant Test Facility (LCTF) is proposed to be built and operated by the Idaho National Laboratory (INL). These technical functions and requirements provided guidance for the lead loop coolant facility pre-conceptual design and cost estimate. The detailed designs will be developed based on these concepts by the Idaho National Laboratory (INL) in coordination with other national laboratories and subcontractors, as needed.  \nThe LCTF concept, as shown in Figure, is based on the Generation IV International Forum (GIF) goals. The GIF along with the U.S. Department of Energy’s (DOE) Nuclear Energy Research Advisory Committee (NERAC), has published “A Technological Roadmap for Generation IV Nuclear Energy Systems,” which defines eight goals in the four broad areas of sustainability, economics, safety and reliability, and proliferation resistance and physical protection.  \nOf the six most promising Generation IV nuclear energy systems selected by the GIF for further development, the Lead-alloy Cooled Fast Reactor (LFR) system is not only inherently passive-safe but is also good proliferation-resistant. The LFR system is supported by the U.","cbCailjJvivRfqYg","https://ap.wps.com/l/cbCailjJvivRfqYg","pdf",2570008,73,"English","# ABSTRACT\n# SUMMARY","[{\"question\":\"What is the purpose of the Lead Coolant Test Facility (LCTF)?\",\"answer\":\"The LCTF is designed to simulate lead coolant fast reactor (LFR) coolant flow in an open lattice geometry core using seven electrical rods and liquid lead or lead-bismuth eutectic.\"},{\"question\":\"How are the requirements organized in the report?\",\"answer\":\"Five broad requirement areas are identified and then divided into twenty-one specific requirements spanning topics such as coolant temperature, design lifetime, engineering, QA, and environmental requirements.\"},{\"question\":\"What are the reported thermal-hydraulic and instrumentation basis values?\",\"answer\":\"The thermal-hydraulic design is based on a maximum simulated core power of 7 electrical heater rods at 420 kW, an average linear heat generation rate of 300 W/cm, a core inlet temperature of 420°C, and approximately seventy-five data measurements including pressure, temperature, and flow rates.\"}]","Lead Coolant Test Facility Technical and Functional Requirements, Conceptual Design, Cost and Construction Schedule | PDF",1790335635,184,[148,152,156,160,164,168,172,176],{"page_no":22,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/771a224bbe935b9372d69a9240eb154e.webp",983,1272,{"page_no":26,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/b05a0218c4bf963c07319fb0987ab86e.webp",982,1270,{"page_no":30,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/35ead55150af4e6ff4c05f50f206524a.webp",981,1269,{"page_no":33,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/cc5063a36c2f8d211ed966a4d668ad07.webp",980,1268,{"page_no":97,"url":165,"width":166,"height":167},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/5e341668934da438e346197c8ee4c6fc.webp",979,1267,{"page_no":102,"url":169,"width":170,"height":171},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/d238fc0e81732c8efe59505ee1688c81.webp",978,1265,{"page_no":107,"url":173,"width":174,"height":175},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/b32ea895dd42fabe70043a8a8f0d6582.webp",977,1264,{"page_no":112,"url":177,"width":178,"height":179},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/2d5011d215c8f6439e68890b13841032.webp",976,1263]