[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-562775-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-562775-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","le-ale-1a-16a-power-relay-for-micro-wave-oven-rohs-compliant","LE (ALE) - 1a 16A power relay for micro wave oven - RoHS compliant","","RoHS compliant LE (ALE) 16A power relay designed for microwave ovens, supporting magnetron and heater load switching. Features include excellent heat resistance up to 85°C, certified UL coil insulation class B and class F, and high insulation performance with a minimum 8 mm creepage/clearance. Low operating power is achieved with nominal 400 mW for standard and 200 mW for high sensitive types. Multiple safety approvals (UL, CSA, TÜV, VDE) and broad ordering options cover standard and high sensitive variants with different terminal and PCB forms.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/le-ale-1a-16a-power-relay-for-micro-wave-oven-rohs-compliant/562775/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/le-ale-1a-16a-power-relay-for-micro-wave-oven-rohs-compliant/562775.png","ImageObject",300,407,{"name":42,"@type":43},"hdkawk","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-22","2026-10-12",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",6,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What loads can the LE (ALE) relay switch in a microwave oven?","Question",{"text":63,"@type":64},"It supports switching magnetron and heater loads found in microwave ovens.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What operating temperature and insulation ratings are specified?",{"text":68,"@type":64},"Ambient temperature can reach up to 85°C, and the coil insulation is certified as class B and class F. High insulation includes a minimum 8 mm creepage distance/clearances between contact and coil.",{"name":70,"@type":61,"acceptedAnswer":71},"How do the standard and high sensitive types differ in operating power?",{"text":72,"@type":64},"The standard type has nominal operating power of 400 mW, while the high sensitive type is specified at 200 mW.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},562775,1791863362,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":97,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144},3985747859855,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","RoHS compliant  \n\n| |  | \u003Cbr>VDE | |\n| --- | --- | --- | --- |\n| 1a 16A power relay for micro wave oven | LE RELAYS (ALE) |  |  |\n\nFEATURES  \n1. Supports magnetron and heater loads.  \nCapable for switching magnetron and heater loads found in microwave ovens.  \n2. Excellent heat resistance  \nAmbient temperature: up to 85°C 185°FCertiﬁed UL coil insulation class B and class F  \n3. High insulation resistance  \nCreepage distance and clearances between contact and coil:  \nMin. 8 mm .315 inch  \nSurge withstand voltage: 10,000V  \n4. Low operating power  \nNominal operating power: 400mW/ 200mW (High sensitive type)  \n5. A wide variety of types  \nProduct line consists of 4 types with different shapes and pins  \n6. Conforms to the various safety standards:  \nUL, CSA, TÜV andVDE approved  \nUL, CSA and VDE approved (PCB type)  \nTYPICAL APPLICATIONS  \n• Microwave ovens  \n• Refrigerators  \n• OA equipment  \n\n| ORDERING INFORMATION |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| ALE\u003Cbr>LE relay  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Contact arrangement\u003Cbr>1: 1 Form A (400 mW)\u003Cbr>7: 1 Form A (200 mW) |  |  |  |  |  |  |  |  |  |  |  |  |\n| Terminal shape\u003Cbr>2: TMP type/PCB side three terminals (includes one dummy terminal)\u003Cbr>3: TMP type/PCB side three terminals\u003Cbr>4: TMP type/PCB side four terminals\u003Cbr>P: PCB type (No tab terminals) |  |  |  |  |  |  |  |  |  |  |  |  |\n| Coil insulation class\u003Cbr>B: Class B insulation\u003Cbr>F: Class F insulation |  |  |  |  |  |  |  |  |  |  |  |  |\n| Nominal coil voltage, V DC\u003Cbr>05: 5, 06: 6, 09: 9, 12: 12, 18: 18, 24: 24, 48: 48 |  |  |  |  |  |  |  |  |  |  |  |  |\n| Notes: • Certified by UL, CSA, TÜV and VDE (TMP type) .\u003Cbr>• Certified by UL, CSA and VDE (PCB type) . |  |  |  |  |  |  |  |  |  |  |  |  |\n\nPanasonic Corporation Automation Controls Business Unit [industrial.panasonic.com/ac/e/](industrial.panasonic.com/ac/e/ ASCTB194E)[ ASCTB194E](industrial.panasonic.com/ac/e/ ASCTB194E) 201202-T  \nLE (ALE)  \nTYPES  \n1. Standard type  \n\n| Contact\u003Cbr>arrangement | Nominal coil\u003Cbr>voltage | TMP type |  |  | PCB type\u003Cbr>(No tab terminals) |\n| --- | --- | --- | --- | --- | --- |\n|  |  | PCB side three terminals\u003Cbr>(includes one dummy terminal) | PCB side three terminals | PCB side four terminals |  |\n|  |  | Part No. | Part No. | Part No. | Part No. |\n| 1 Form A | 5V DC | ALE12❍05 | ALE13❍05 | ALE14❍05 | ALE1P❍05 |\n|  | 6V DC | ALE12❍06 | ALE13❍06 | ALE14❍06 | ALE1P❍06 |\n|  | 9V DC | ALE12❍09 | ALE13❍09 | ALE14❍09 | ALE1P❍09 |\n|  | 12V DC | ALE12❍12 | ALE13❍12 | ALE14❍12 | ALE1P❍12 |\n|  | 18V DC | ALE12❍18 | ALE13❍18 | ALE14❍18 | ALE1P❍18 |\n|  | 24V DC | ALE12❍24 | ALE13❍24 | ALE14❍24 | ALE1P❍24 |\n|  | 48V DC | ALE12❍48 | ALE13❍48 | ALE14❍48 | ALE1P❍48 |\n\n❍: Input the following letter. Class B: B, Class F: F  \nNote: Standard packing; Carton: 100 pcs. Case 500 pcs.  \n2. High sensitive type  \n\n| Contact\u003Cbr>arrangement | Nominal coil\u003Cbr>voltage | TMP type |  |  | PCB type\u003Cbr>(No tab terminals) |\n| --- | --- | --- | --- | --- | --- |\n|  |  | PCB side three terminals\u003Cbr>(includes one dummy terminal) | PCB side three terminals | PCB side four terminals |  |\n|  |  | Part No. | Part No. | Part No. | Part No. |\n| 1 Form A\u003Cbr>(High sensitivity:\u003Cbr>200mW) | 5V DC | ALE72❍05 | ALE73❍05 | ALE74❍05 | ALE7P❍05 |\n|  | 6V DC | ALE72❍06 | ALE73❍06 | ALE74❍06 | ALE7P❍06 |\n|  | 9V DC | ALE72❍09 | ALE73❍09 | ALE74❍09 | ALE7P❍09 |\n|  | 12V DC | ALE72❍12 | ALE73❍12 | ALE74❍12 | ALE7P❍12 |\n|  | 18V DC | ALE72❍18 | ALE73❍18 | ALE74❍18 | ALE7P❍18 |\n|  | 24V DC | ALE72❍24 | ALE73❍24 | ALE74❍24 | ALE7P❍24 |\n|  | 48V DC | ALE72❍48 | ALE73❍48 | ALE74❍48 | ALE7P❍48 |\n\n❍: Input the following letter. Class B: B, Class F: F  \nNote: Standard packing; Carton: 100 pcs. Case 500 pcs.  \nRATING 1. Coil data  \n1) Standard type  \n\n| Nominal coil\u003Cbr>voltage | Pick-up voltage\u003Cbr>(at 20°C 68°F) | Drop-out voltage\u003Cbr>(at 20°C 68°F) | Nominal ope","cbCail4OrDtom3qu","https://ap.wps.com/l/cbCail4OrDtom3qu","pdf",91892,"English","# Features\n## Heat resistance and insulation performance\n## Low operating power and product variety\n# Typical applications\n# Ordering information\n## Contact arrangement and terminal shapes\n## Coil insulation class and nominal coil voltages\n# Types and part number tables\n## Standard type\n## High sensitive type\n# Ratings and specifications","[{\"question\":\"What loads can the LE (ALE) relay switch in a microwave oven?\",\"answer\":\"It supports switching magnetron and heater loads found in microwave ovens.\"},{\"question\":\"What operating temperature and insulation ratings are specified?\",\"answer\":\"Ambient temperature can reach up to 85°C, and the coil insulation is certified as class B and class F. High insulation includes a minimum 8 mm creepage distance/clearances between contact and coil.\"},{\"question\":\"How do the standard and high sensitive types differ in operating power?\",\"answer\":\"The standard type has nominal operating power of 400 mW, while the high sensitive type is specified at 200 mW.\"}]","LE (ALE) - 1a 16A power relay for micro wave oven - RoHS compliant | PDF",1791809709,13]