[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-662352-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-662352-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","lclv-aireguard-remote-startup-assistance-sb-010a-commissioning-preparation-checklist","LC/LV AireGuard Remote Startup Assistance - SB-010A - Commissioning Preparation Checklist","","LC/LV AireGuard Remote Startup Assistance outlines how Desert Aire uses remote assistance to support a job-site technician in completing the commissioning process for a dehumidifier. The document specifies remote navigation via field Ethernet and guidance for mechanical adjustments. It also provides a detailed pre-start checklist covering leak checks, leveling, duct and condensate components, remote condenser plumbing and refrigerant charging verification, refrigeration line preparation, sensor and electrical verification, and required tools for commissioning adjustments. It includes unit, jobsite, and contractor information plus scheduling and submission instructions.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/lclv-aireguard-remote-startup-assistance-sb-010a-commissioning-preparation-checklist/662352/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/lclv-aireguard-remote-startup-assistance-sb-010a-commissioning-preparation-checklist/662352.png","ImageObject",300,407,{"name":42,"@type":43},"Blitz","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":22},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"How does Desert Aire provide remote start-up assistance?","Question",{"text":62,"@type":63},"Desert Aire remotely assists the job-site technician through a field-installed Ethernet connection, allowing it to navigate the controller and verify critical setup details. The job-site technician performs adjustments under Desert Aire guidance as needed to complete commissioning.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What items must be completed on site before Desert Aire can schedule commissioning?",{"text":67,"@type":63},"The site must complete leak checks and inspections, properly level and support the unit, install outside air duct components if applicable, install condensate P Trap with heat trace for winter operation, plumb the remote condenser correctly, purge and record gas heater lines, and prepare refrigeration lines, sensors, and electrical connections.",{"name":69,"@type":60,"acceptedAnswer":70},"What tools and equipment are required to make system adjustments?",{"text":71,"@type":63},"Required tools include volt/amp/ohm meters and refrigerant manifold gauges, hand tools (refrigeration service and general wrenches/screwdrivers), air balancing equipment such as a Magnehelic or manometer differential pressure gauge, and a refrigerant cylinder plus supporting scales. It also calls for a hand pump for adding oil to compressors and specified POE oils.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},662352,1793212744,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":96},24464137899374,"https://us-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","LC/LV AireGuard Remote Startup Assistance  \n.  \nAireGuard Assisted Start Up consists of a Desert Aire factory technician remotely assisting a job-site technician to complete the commissioning process of the dehumidifier. Using a field installed Ethernet connection, Desert Aire will be able to navigate the controller and verify critical set up details to ensure proper equipment operation. The field technician will work under the guidance of Desert Aire to make any mechanical adjustments identified by Desert Aire to complete the commissioning process.  \nPrior to scheduling start-up with Desert Aire, the site must be fully prepared for commissioning with the following items completed.  \nJob Site Preparation-Items completed by the installing contractor before Start-Up can be scheduled:  \n􀂆 Dehumidifier leak checked and inspected for internal concealed damage – remove access panels and inspect the interior of the unit for transit damage. Contact Desert Aire immediately if damage is noted (262)946-7400  \n􀂆 Dehumidifier leveled and properly supported per the installation manuals recommendations. See section 2.1 of the LC/LV I&O manual for details  \n􀂆 Outside air duct filters and damper installed (if applicable)– See LC/LV I&O manual section 2.2 for details  \n􀂆 Condensate P Trap installed with heat trace for winter operation. See LC/LV I&O manual section 2.3 for details  \n􀂆 Remote condenser plumbed per Air Cooled I&O manual section 2.4, check valve installed in the hot gas discharge line, leak checked, evacuated, and charged if necessary. LC and LV Units require additional field charging. Refer to the charge label affixed to the unit for details. Please verify and document the Refrigerant volume added to the Remote Condenser   lbs.(if applicable)  \n􀂆 Gas heater lines plumbed and purged / Record gas pressure entering the unit -  ’wc (if applicable)  \n􀂆 Refrigeration line set is clamped and the header supported per the Air Cooled &O manual sec 2.3  \n􀂆 Pressure transducer and cord sent with the remote condenser installed on the liquid line header and wired to the Johnson 450 controller. See section 2.7 of the Air Cooled I&O manual for wiring details. (if applicable)  \n􀂆 All electrical connections terminated and verified for proper voltage at the Dehumidifier and the Remote Condenser (if applicable)  \n􀂆 Temperature / RH sensors –(wall mount applications only) installed per the LC/LV I&O manual Section 2.7,􀂆 Optional Water Condenser circuit connected to dehumidifier with flow meter, balancing valves and temperature  \nsensors installed in circuit.  \n􀂆 Remove shipping blocks from compressors and blowers.  \n􀂆 Ethernet Connection – Verify the RJ-45 Ethernet connection is installed and active.  \nTool Requirements – These items are required to make adjustments to the system  \n􀂆 Volt/Amp/OHM meters. / Refrigerant Manifold Gauges  \n􀂆 Hand Tools – Refrigeration Service Wrenches, Allen Wrenches, Assorted Screwdrivers & Crescent Wrenches  \n􀂆 Air Balancing Equipment (Magnehelic or Manometer differential pressure gauge – one inch scale is preferred)  \n􀂆 25 \\# cylinder of the appropriate refrigerant & scale.  \n􀂆 Hand pump for adding oil to compressors and 1 gallon of one of the following POE oils: Copeland Ultra 32-3MAF  \nLubrizol Emkarate RL32-3MAF  \nPark Emkarate RL32-3MAF  \nNu Calgon 4314-66 (RL32-3MAF  \n(This is required on split systems based on line set calculations and oil recovery traps )  \nPage 1 of 2 SB-010A  \nRev 1.docx1  \nLC/LV AireGuard Remote Startup Assistance  \n.  \nUnit Information  \nModel \\#  Serial \\#   \nJobsite Information  \nJob site name   \nJob Site Address  \n____________________________________________________  \nContractor Information  \nInstalling Contractor:  Manager’s Name :  Phone \\#:  Field Technicians Name :  Cell \\#   \nIf you are unable to supply any of the required equipment you must contact Desert Aire before returning this document.  \nI agree that the items listed above have been completed as of   (Date) Once this form is c","cbCainnSQH9SQ1ek","https://ap.wps.com/l/cbCainnSQH9SQ1ek","pdf",26094,"English","# Unit Information\n## Job Site Information\n## Contractor Information\n## Submission and Scheduling","[{\"question\":\"How does Desert Aire provide remote start-up assistance?\",\"answer\":\"Desert Aire remotely assists the job-site technician through a field-installed Ethernet connection, allowing it to navigate the controller and verify critical setup details. The job-site technician performs adjustments under Desert Aire guidance as needed to complete commissioning.\"},{\"question\":\"What items must be completed on site before Desert Aire can schedule commissioning?\",\"answer\":\"The site must complete leak checks and inspections, properly level and support the unit, install outside air duct components if applicable, install condensate P Trap with heat trace for winter operation, plumb the remote condenser correctly, purge and record gas heater lines, and prepare refrigeration lines, sensors, and electrical connections.\"},{\"question\":\"What tools and equipment are required to make system adjustments?\",\"answer\":\"Required tools include volt/amp/ohm meters and refrigerant manifold gauges, hand tools (refrigeration service and general wrenches/screwdrivers), air balancing equipment such as a Magnehelic or manometer differential pressure gauge, and a refrigerant cylinder plus supporting scales. It also calls for a hand pump for adding oil to compressors and specified POE oils.\"}]","LC/LV AireGuard Remote Startup Assistance - SB-010A - Commissioning Preparation Checklist | PDF"]