[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-464194-105":59,"doc-detail-464194-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","laboratory-evaluation-of-armie-a-portable-sps30-based-low-cost-sensor-node-for-pm25-monitoring","Laboratory Evaluation of ARMIE, a Portable SPS30-Based Low-Cost Sensor Node for PM2.5 Monitoring","","Low-cost particulate matter sensors create new possibilities for exposure monitoring, but they must be evaluated before use in epidemiological studies. This study tested the performance of the SPS30 sensor integrated into the ARMIE portable monitoring sensor-node under controlled laboratory conditions. Sensors were co-located with reference instruments (DustTrak, SMPS+APS) across multiple aerosol sources and humidity conditions. Calibration strategies reduced mean errors, and results showed strong agreement with DustTrak, with moderate agreement versus SMPS+APS.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/laboratory-evaluation-of-armie-a-portable-sps30-based-low-cost-sensor-node-for-pm25-monitoring/464194/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/laboratory-evaluation-of-armie-a-portable-sps30-based-low-cost-sensor-node-for-pm25-monitoring/464194.png","ImageObject",300,407,{"name":92,"@type":93},"CatatanPagi","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-20","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",18,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What does the ARMIE system combine and what is it designed to measure?","Question",{"text":113,"@type":114},"The ARMIE portable monitoring sensor-node integrates a Sensirion SPS30 sensor to measure PM2.5 particle concentrations for exposure monitoring.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How were the ARMIE sensors evaluated in the laboratory study?",{"text":118,"@type":114},"ARMIE sensors were co-located with DustTrak and with SMPS+APS across multiple aerosol sources (e.g., candle burning, cooking, cigarette smoke) under regular and high-humidity conditions, with calibration assessed using leave-one-sensor-out and leave-one-source-out methods.",{"name":120,"@type":111,"acceptedAnswer":121},"How did the ARMIE node perform relative to the reference instruments?",{"text":122,"@type":114},"ARMIE showed strong agreement with the DustTrak photometer (r = 0.93–0.98) and maintained linear response characteristics; agreement with SMPS+APS was moderate (r = 0.74–0.94) with systematic underestimation at higher concentrations.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},464194,1791039270,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},962090894170,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Article  \nLaboratory Evaluation of ARMIE, a Portable SPS30-Based Low-Cost Sensor Node for PM2.5 Monitoring  \nAsbjørn Kloppenborg 1, *, Louise B. Frederickson 2, Rasmus Ø. Nielsen 1,3, Clive E. Sabel 4, Tue Skallgaard 1, Jakob Löndahl 5, Jose G. C. Laurent 6 and Torben Sigsgaard 1  \n1 Department of Public Health, Aarhus University, 8000 Aarhus C, Denmark; [ts@ph.au.dk](ts@ph.au.dk) (T.S.)  \n2 Department of Environmental Science, Aarhus University, 4000 Roskilde, Denmark  \n3 Research Unit for General Practice in Aarhus, 8000 Aarhus C, Denmark  \n4 School of Geography, Earth and Environmental Sciences, University of Plymouth, Plymouth PL4 8AA, UK  \n5 Division of Ergonomics and Aerosol Technology, Lund University, 22100 Lund, Sweden  \n6 Department of Environmental and Occupational Health and Justice, Rutgers School of Public Health, Piscataway, NJ 08854, USA  \n* Correspondence: [askl@ph.au.dk](askl@ph.au.dk)  \nAbstract  \nBackground: Low-cost particulate matter sensors have enabled new opportunities for exposure monitoring but require evaluation before application in epidemiological studies. This study assessed the performance of the SPS30 sensor integrated into the ARMIE portable monitoring sensor-node under controlled laboratory conditions. Methods: Sensors were co-located with two comparison instruments—the optical DustTrak photometer and the combined Scanning Mobility Particle Sizer (SMPS) and Aerodynamic Particle Sizer (APS)—across multiple aerosol sources, including candle burning, cooking, cigarette smoke, and clean air, under both regular and high-humidity conditions. Calibration performance was evaluated using leave-one-sensor-out and leave-one-source-out approaches. Results: The ARMIE node demonstrated strong agreement with the DustTrak (r = 0.93–0.98) and maintained linear response characteristics across emission types. Calibration reduced mean errors and narrowed the limits of agreement. Agreement with the SMPS + APS was moderate (r = 0.74–0.94) and characterized by systematic underestimation at higher concentrations. Conclusions: Overall, the ARMIE node achieved high correlation with the DustTrak, demonstrating that low-cost optical sensors can reliably capture temporal variability in particle concentrations relative to mid-cost photometers.  \nKeywords: low-cost sensors; SPS30; PM2.5 monitoring; sensor calibration; performance evaluation; exposure assessment; environmental epidemiology  \nAcademic Editor: Erwin Peiner  \nReceived: 6 November 2025  \nRevised: 18 December 2025  \nAccepted: 23 December 2025  \nPublished: 2 January 2026  \nCopyright: © 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1. Introduction  \nAir pollution remains a leading environmental determinant of premature morbidity and mortality worldwide. Fine particulate matter (PM 2.5; particles 2.5 µm in diameter and smaller) alone accounts for millions of deaths annually and is a major contributor to the global burden of disease [1] . Epidemiological studies consistently link short-term fluctuations in PM2.5 to acute events, such as myocardial infarction and arrhythmias, which can occur within hours of exposure peaks [2] . However, most exposure assessments rely on fixed-site monitors, which may underestimate individual risk due to spatial and temporal heterogeneity of urban air pollution [3] .  \nIndividual exposure often diverges from ambient concentrations across microenvironments and daily activities [4] . Commuting, cooking, and burning candles or using e-cigarettes can produce disproportionately high personal exposures despite low background levels [5,6] . Because acute cardiovascular responses can occur within hours of exposure peaks, temporal resolution may be as important as spatial coverage in capturing risk-relevant fluctuations. This ambient–personal exposure misclassification may bias risk estimates by dim","cbCailyd2Fcgyc02","https://ap.wps.com/l/cbCailyd2Fcgyc02","pdf",15509510,36,"English","# Abstract\n# Introduction\n# Laboratory evaluation methods\n## Aerosol sources and humidity conditions\n## Reference instruments and calibration approaches\n# Results\n## Agreement and linearity\n## Error reduction through calibration\n# Conclusions","[{\"question\":\"What does the ARMIE system combine and what is it designed to measure?\",\"answer\":\"The ARMIE portable monitoring sensor-node integrates a Sensirion SPS30 sensor to measure PM2.5 particle concentrations for exposure monitoring.\"},{\"question\":\"How were the ARMIE sensors evaluated in the laboratory study?\",\"answer\":\"ARMIE sensors were co-located with DustTrak and with SMPS+APS across multiple aerosol sources (e.g., candle burning, cooking, cigarette smoke) under regular and high-humidity conditions, with calibration assessed using leave-one-sensor-out and leave-one-source-out methods.\"},{\"question\":\"How did the ARMIE node perform relative to the reference instruments?\",\"answer\":\"ARMIE showed strong agreement with the DustTrak photometer (r = 0.93–0.98) and maintained linear response characteristics; agreement with SMPS+APS was moderate (r = 0.74–0.94) with systematic underestimation at higher concentrations.\"}]","Laboratory Evaluation of ARMIE, a Portable SPS30-Based Low-Cost Sensor Node for PM2.5 Monitoring | PDF",1790767813,91,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/56e9dc850101c1f46bd058f5753ca8a8.webp",983,1390,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2c2ac17a16d60d01be4878761a3d50c5.webp",982,1388,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/19325f1b989bf0aee767c4ce77034f05.webp",981,1387,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/eba18638338fbfa841bbd77d52037f4a.webp",980,1385]