[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-652251-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-652251-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","kohler-20-2000-kw-industrial-generator-sets-decision-maker-controllers-3-16-light-operation-manual","Kohler - 20-2000 kW Industrial Generator Sets - Decision-Maker Controllers 3+, 16-Light Operation Manual","","Operation manual for industrial generator sets with models rated 20--2000 kW, covering multiple Decision-Maker controller variants including 3+ with 16-Light and 7-Light, 3 with 16-Light, and manual paralleling systems. Provides product identification recording instructions for service parts, safety precautions, and guidance for installation-related documentation. Details specifications, prestart and exercising procedures, microprocessor controller features, normal and prime power operation, emergency stopping, fault shutdowns, and controller reset workflows, plus manual paralleling and expanded controller operation.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/kohler-20-2000-kw-industrial-generator-sets-decision-maker-controllers-3-16-light-operation-manual/652251/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/kohler-20-2000-kw-industrial-generator-sets-decision-maker-controllers-3-16-light-operation-manual/652251.png","ImageObject",300,407,{"name":42,"@type":43},"pixelkiddo","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-29","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":26},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What product identification information needs to be recorded, and why?","Question",{"text":62,"@type":63},"Record product identification numbers from generator set nameplates so service parts can be identified later. Also record field-installed kit numbers after installing kits and capture controller and engine identification details for reference.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What prestart steps are required before operating the generator set?",{"text":67,"@type":63},"Use the prestart checklist before operation, then follow procedures such as generator set exercising to verify readiness prior to normal use.",{"name":69,"@type":60,"acceptedAnswer":70},"How does the manual address emergency stopping and fault shutdown recovery?",{"text":71,"@type":63},"It describes emergency stopping and fault shutdowns, and provides controller resetting procedures after a fault shutdown so operation can be safely resumed once conditions are corrected.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},652251,1793051846,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":26,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":89,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144},962090883892,"https://ap-avatar.wpscdn.com/avatar/e00115db34f3e0f11b?x-image-process=image/resize,m_fixed,w_180,h_180&k=1790152879550218658","Operation  \nIndustrial Generator Sets  \nModels:  \n20--2000 kW  \nControllers:  \nDecision-Maker 􀀂 3+, 16-Light  \nDecision-Maker 􀀂 3+, 7-Light  \nDecision-Maker 􀀂 3, 16-Light  \nDecision-Maker 􀀂 3, 6-Light Manual Paralleling Decision-Maker 􀀂 1 Manual  \nEngine Gauge Box for Paralleling Switchgear  \n~~ ~~ TP-5750 10/03j  \nCalifornia Proposition 65  \n WARNING  \nEngine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.  \nProduct Identification Information  \nProduct identification numbers determine service parts. Record the product identification numbers in the spaces below immediately after unpacking the products so that the numbers are readily available for future reference. Record field-installed kit numbers after installing the kits.  \nGenerator Set Identification Numbers Record the product identification numbers from the generator set nameplate(s) .  \nModel Designation   Specification Number    \nSerial Number   Accessory Number Accessory Description  \nController Identification  \nRecord the controller description from the generator set operation manual, spec sheet, or sales invoice.  \nController Description    \nEngine Identification  \nRecord the product identification information from the engine nameplate.  \nManufacturer   Model Designation   Serial Number    \n2 TP-5750 10/03  \nTable of Contents  \nProduct Identification Information ............................................................ 2  \nSafety Precautions and Instructions ........................................................ 5  \nIntroduction ............................................................................... 9  \nService Assistance ........................................................................ 9  \nSection 1 Specifications ................................................................... 11  \n1.1 Introduction .......................................................... 11  \n1.2 Specifications, 20--300 kW ............................................. 11  \n1.3 Specifications, 350--2000 kW ........................................... 12  \n1.4 Accessories .......................................................... 12  \n1.4.1 Controller Connection Kit (M) ................................... 12  \n1.4.2 Remote Annunciator Kit (M) .................................... 12  \n1.4.3 Single-Relay Dry Contact Kit (M) ................................ 13  \n1.4.4 Dry Contact Kits (M) ........................................... 13  \n1.4.5 Audiovisual Alarm (M) .......................................... 14  \n1.4.6 Safeguard Breaker ............................................ 14  \n1.4.7 Line Circuit Breaker ........................................... 14  \n1.4.8 Run Relay Kit ................................................. 14  \n1.4.9 Remote Emergency Stop Kit (M) ................................ 15  \n1.4.10 FASTCHECK Diagnostic Tester (M) .............................. 15  \n1.4.11 Accessory and Prime Power Terminal Strip Connections (M) ........ 16  \nSection 2 Operation ....................................................................... 19  \n2.1 Prestart Checklist ..................................................... 19  \n2.2 Generator Set Exercising ............................................... 19  \n2.3 Microprocessor Controllers Features ..................................... 20  \n2.3.1 Microprocessor Controller Features .............................. 20  \n2.3.2 Normal Operation ............................................. 28  \n2.3.3 Prime Power Mode Operation (Decision-Maker 3+ Controller) ....... 28  \n2.3.4 Emergency Stopping .......................................... 29  \n2.3.5 Fault Shutdowns .............................................. 30  \n2.3.6 Controller Resetting After a Fault Shutdown ....................... 30  \n2.4 Manual Paralleling Controller ........................................... 31  \n2.4.1 Manual Paralleling Controller Features ........................... ","cbCaidIO84Lxk1gy","https://ap.wps.com/l/cbCaidIO84Lxk1gy","pdf",2535351,"English","# Product Identification Information\n# Safety Precautions and Instructions\n# Introduction\n# Service Assistance\n# Section 1 Specifications\n## 1.1 Introduction\n## 1.2 Specifications, 20--300 kW\n## 1.3 Specifications, 350--2000 kW\n## 1.4 Accessories\n## 2.1 Prestart Checklist\n## 2.2 Generator Set Exercising\n## 2.3 Microprocessor Controllers Features\n## 2.3.2 Normal Operation\n## 2.3.3 Prime Power Mode Operation (Decision-Maker 3+ Controller)\n## 2.4 Manual Paralleling Controller\n## 2.5 Expanded Decision-Maker 1 Controller\n## 2.6 Standard Decision-Maker 1 Controller with Engine Gauges\n## 2.7 Standard Decision-Maker 1 Controller\n## 2.8 Manual Controller","[{\"question\":\"What product identification information needs to be recorded, and why?\",\"answer\":\"Record product identification numbers from generator set nameplates so service parts can be identified later. Also record field-installed kit numbers after installing kits and capture controller and engine identification details for reference.\"},{\"question\":\"What prestart steps are required before operating the generator set?\",\"answer\":\"Use the prestart checklist before operation, then follow procedures such as generator set exercising to verify readiness prior to normal use.\"},{\"question\":\"How does the manual address emergency stopping and fault shutdown recovery?\",\"answer\":\"It describes emergency stopping and fault shutdowns, and provides controller resetting procedures after a fault shutdown so operation can be safely resumed once conditions are corrected.\"}]","Kohler - 20-2000 kW Industrial Generator Sets - Decision-Maker Controllers 3+, 16-Light Operation Manual | PDF",1792879049,202]