[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-640815-105":59,"doc-detail-640815-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","kitchenaid-stand-mixer-service-manual","KitchenAid Stand Mixer Service Manual","","KitchenAid Stand Mixer service manual for professional technicians provides safety-focused instructions and operating checks before repair work. It describes required service environment and electrical precautions, including grounded AC outlets, inspecting the power cord, disconnecting from mains during disassembly/assembly, and using controlled testing without leaving the unit unattended. It also covers normal performance specifications such as RPM by speed position, starting behavior, power verification, heat behavior under heavy loads, and an overview of speed control using a governor assembly and control plate.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/kitchenaid-stand-mixer-service-manual/640815/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/kitchenaid-stand-mixer-service-manual/640815.png","ImageObject",300,407,{"name":92,"@type":93},"jayni","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-26","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety precautions are required before servicing the stand mixer?","Question",{"text":112,"@type":113},"Work in a dry, sanitary area; keep the technician’s hands clean; inspect the unit in a well-lit area; and use protective eyewear. Ensure the unit is disconnected from AC mains during disassembly and assembly.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What should be checked first regarding electrical safety?",{"text":117,"@type":113},"Use properly grounded AC outlets that meet local electrical codes. Inspect the stand mixer power cord first; do not run the mixer if the cord is damaged—replace it.",{"name":119,"@type":110,"acceptedAnswer":120},"What RPM does the mixer reach at different speed settings?",{"text":121,"@type":113},"At the STIR position, the planetary turns at about 60 RPM. At the #10 position, most models turn at about 255 RPM, while K45SS units built before May 6, 2002 run at about 280 RPM.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},640815,1793051848,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},3985747859343,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","SERVICE MANUAL for  \nKITCHENAID  \nSTAND MIXER  \nModels  \nK45SS KSM90  \nKSM110  \nKSM151 KSM5 KSMC50  \nKPM50  \nKSM75  \nKSM103  \nKSM150 K5SS KSM50PKPM5 KP50P  \nPrinted in U.S.A. September, 2005 LIT4177310-C  \nKITCHENAID  \nStand Mixer Service Manual Lit4177310-C 2005 KITCHENAID  \nSafety Guidelines  \nThis Service Manual is written for the Professional Service Technician who has familiarity with the KitchenAid Stand Mixer. The following Safety Guidelines should be adhered to when servicing this product.  \nSERVICE ENVIRONMENT  \n•The workplace will be dry and sanitary at all times and all units should be inspected for cleanliness before any work is started.  \n•Visually inspect the unit requiring service in a well luminated area.  \n•A mild, non-abrasive dishwashing soap solution and clean towel can be used to wash any unit requiring attention.  \n•The hands of the service technician should be clean at all times during service procedure.  \nELECTRICAL CONSIDERATIONS  \n•The workplace for the stand mixer will have properly grounded AC outlets that adhere to all Local Electrical Codes that are applicable at the time of repair.  \n•The Stand Mixer Power Cord should always be inspected first before testing the mixer operation. Do NOT run the mixer if the Power Cord is damaged--replace it.  \n•All disassembly and assembly procedures discussed in this manual should be conducted with the unit disconnected from the AC mains.  \n•Do NOT leave the unit unattended while running the mixer for speed range and bowl clearance checks. Always unplug the unit immediately after concluding these tests.  \nTechnician  \n•The Service Technician should wear Protective Eyewear at all times when conducting a repair on the Stand Mixer.  \n•Loose fitting sweaters, shirts sleeves or bracelets should NOT be worn while servicing the Stand Mixer.  \nSAFETY  \nINDEX: Stand Mixer Repair Manual  \nK45SS KSM75 KSM90 KSM103 KSM110 KSM150 KSM151  \nK5SS KSM5 KSM50P KSMC50 KPM5 KPM50 KP50P  \nSECTION SUBJECT PAGE  \n- General Information 1  \n1 Disassembly of Gearcase and Planetary 2  \n2 Disassembly of Motor and Control Unit 6  \n3 Repairs to Motor and Control Unit 11  \n4 Repairs to Gearcase and Planetary 16  \n5 Repairs to Pedestal 21  \n6 Adjustment to Control Unit 22  \n7 Repairs to Bowl Lift Assembly 26  \n8 Troubleshooting the Bowl Lift Assembly 30  \nAPPENDIX SUBJECT  \nA Tools Required for Stand Mixer Service  \nB Problem Solving Quick Reference Guide  \nC Domestic Model Wiring Diagram  \nD International Model Wiring Diagram-RF Filter  \nE International Model Wiring Diagram-Bowl Interlock RF Filter  \nF Stand Mixer Serial Number Codes  \nIntroduction  \nAll KitchenAid Stand Mixers are well designed and carefully built. Normally they will give continual use year after year without service attention.  \nCareful records have been maintained over a period of years to determine and correct, through improved design, any troubles that might possibly develop.  \nAn effort has been made in preparation of this manual to cover them all.  \nINDEX  \nKITCHENAID  \nStand Mixer Service Manual LIT4177310-C 2005 KitchenAid  \nGENERAL INFORMATION  \nNormal Performance  \nThe KitchenAid Stand Mixer is powered with a universal motor which will operate on 50 or 60 hertz, alternating current only.  \nThe Voltage of the power supply should be within 10 volts either way of the voltage stamped on the mixer trimband and nameplate.  \nA mixer in good running condition will start turning slowly when the switch lever is moved from the “OFF”position to the “STIR” position.  \nAs the switch lever is moved to successively higher positions, the speed of the beater increases until the \\#10 speed is reached.  \nAt stir position, the planetary should turn at approximately 60 RPM; at the \\#10 position all models turn at approximately 255 RPM, with the exception of K45SS models built before May 6th, 2002 (WM19), which turn at approximately 280 RPM.  \nKITCHENAID STAND MIXER RPM  \nSPEED *K45SS OTHER MODELS  \nSTIR 60 RPM 60 RPM  \n\\#10 255 RPM 255 R","cbCaitM2t2ZwmjLJ","https://ap.wps.com/l/cbCaitM2t2ZwmjLJ","pdf",2541914,42,"English","# Safety Guidelines\n## Service Environment\n## Electrical Considerations\n## Technician Safety\n# Safety Index: Stand Mixer Repair Manual\n## General Information\n## Normal Performance","[{\"question\":\"What safety precautions are required before servicing the stand mixer?\",\"answer\":\"Work in a dry, sanitary area; keep the technician’s hands clean; inspect the unit in a well-lit area; and use protective eyewear. Ensure the unit is disconnected from AC mains during disassembly and assembly.\"},{\"question\":\"What should be checked first regarding electrical safety?\",\"answer\":\"Use properly grounded AC outlets that meet local electrical codes. Inspect the stand mixer power cord first; do not run the mixer if the cord is damaged—replace it.\"},{\"question\":\"What RPM does the mixer reach at different speed settings?\",\"answer\":\"At the STIR position, the planetary turns at about 60 RPM. At the #10 position, most models turn at about 255 RPM, while K45SS units built before May 6, 2002 run at about 280 RPM.\"}]","KitchenAid Stand Mixer Service Manual | PDF",1792711679,106]